Researcher profile

Patrick Hallen

Patrick Hallen contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2019arXiv

Comments on the NEMA NU 4-2008 Standard on Performance Measurement of Small Animal Positron Emission Tomographs

The National Electrical Manufacturers Association's (NEMA) NU 4-2008 standard specifies methodology for evaluating the performance of small-animal PET scanners. The standard's goal is to enable comparison of different PET scanners over a wide range of technologies and geometries used. In this work, we discuss if the NEMA standard meets these goals and we point out potential flaws and improvements to the standard. For the evaluation of spatial resolution, the NEMA standard mandates the use of filtered backprojection reconstruction. This reconstruction method can introduce star-like artifacts for detectors with an anisotropic spatial resolution, usually caused by parallax error. These artifacts can then cause a strong dependence of the resulting spatial resolution on the size of the projection window in image space, whose size is not fully specified in the NEMA standard. We show that the standard's equations for the estimation of the random rate for PET systems with intrinsic radioactivity are circular and not satisfiable. We compare random rates determined by a method based on the standard to to random rates obtained using a delayed coincidence window and two methods based on the singles rates. We discuss to what extend the NEMA standard's protocol for the evaluation of the sensitivity is unclear and ambiguous, which can lead to unclear interpretations of publicizeded results. The standard's definition of the recovery coefficients in the image quality phantom includes the maximum activity in a region of interest, which causes a positive correlation of noise and recovery coefficients. This leads to an unintended trade-off between desired uniformity, which is negatively correlated with variance (i.e. noise), and recovery. With this work, we want to start a discussion on possible improvements in a next version of the NEMA NU-4 standard.

preprint2016arXiv

Initial PET Performance Evaluation of a Preclinical Insert for PET/MRI with Digital SiPM Technology

Hyperion-IID is a positron emission tomography (PET) insert which allows simultaneous operation in a clinical magnetic resonance imaging (MRI) scanner. To read out the scintillation light of the employed LYSO crystal arrays with a pitch of 1 mm pitch and 12 mm in height, digital silicon photomultipliers (DPC 3200-22, Philips Digital Photon Counting) (DPC) are used. The basic PET performance in terms of energy resolution, coincidence resolution time (CRT) and sensitivity as a function of operating parameters, such as the operating temperature, the applied overvoltage, activity and configuration parameters of the DPCs, were evaluated on system level. The measured energy resolution did not show a large dependency on the selected parameters and is in the range of 12.4-12.9% for low activities and degrades to ~13.6% at activities of ~100 MBq. The CRT strongly depends on the selected trigger scheme (trig) of the DPCs. We measured approximately 260 ps, 440 ps, 540 ps and 1300 ps for trig 1-4, respectively. The trues sensitivity for a NEMA NU 4 mouse-sized scatter phantom with a 70-mm-long tube of activity was dependent on the operating parameters and was determined to be 0.4-1.4% at low activities. The random fraction stayed below 5% at activities up to 100 MBq and the scatter fraction was evaluated as ~6% for an energy window of 411-561 keV and ~16% for 250-625 keV. Furthermore, we performed imaging experiments using a mouse-sized hot-rod phantom and a large rabbit-sized phantom. In 2D slices of the reconstructed mouse-sized hot-rod phantom (Ø = 28 mm), the rods were distinguishable from each other down to a rod size of 0.8 mm. There was no benefit of the better CRT of trig 1 over trig 3, where in the larger rabbit-sized phantom (Ø = 114 mm), we could show a clear improvement of image quality using the time-of-flight information.