Source author record

Patrick Gill

Patrick Gill appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

8works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2020arXiv

A mid-infrared magneto-optical trap of metastable strontium for an optical lattice clock

We report on the realization of a magneto-optical trap (MOT) for metastable strontium operating on the 2.92 $μ$m transition between the energy levels $5s5p~^3\mathrm{P}_2$ and $5s4d~^3\mathrm{D}_3$. The strontium atoms are initially captured in a MOT operating on the 461 nm transition between the energy levels $5s^2~^1\mathrm{S}_0$ and $5s5p~^1\mathrm{P}_1$, prior to being transferred into the metastable MOT and cooled to a final temperature of 6 $μ$K. Challenges arising from aligning the mid-infrared and 461 nm light are mitigated by employing the same pyramid reflector to realize both MOTs. Finally, the 2.92 $μ$m transition is used to realize a full cooling sequence for an optical lattice clock, in which cold samples of $^{87}\mathrm{Sr}$ are loaded into a magic-wavelength optical lattice and initialized in a spin-polarized state to allow high-precision spectroscopy of the $5s^2~^1\mathrm{S}_0$ to $5s5p~^3\mathrm{P}_0$ clock transition.

preprint2019arXiv

Cavity-enhanced non-destructive detection of atoms for an optical lattice clock

We demonstrate a new method of cavity-enhanced non-destructive detection of atoms for a strontium optical lattice clock. The detection scheme is shown to be linear in atom number up to at least 10,000 atoms, to reject technical noise sources, to achieve signal to noise ratio close to the photon shot noise limit, to provide spatially uniform atom-cavity coupling, and to minimize inhomogeneous ac Stark shifts. These features enable detection of atoms with minimal perturbation to the atomic state, a critical step towards realizing an ultra-high-stability, quantum-enhanced optical lattice clock.

preprint2016arXiv

A low maintenance Sr optical lattice clock

We describe the Sr optical lattice clock apparatus at NPL with particular emphasis on techniques used to increase reliability and minimise the human requirement in its operation. Central to this is a clock-referenced transfer cavity scheme for the stabilisation of cooling and trapping lasers. We highlight several measures to increase the reliability of the clock with a view towards the realisation of an optical time-scale. The clock contributed 502 hours of data over a 25 day period (84% uptime) in a recent measurement campaign with several uninterrupted periods of more than 48 hours. An instability of $2\times10^{-17}$ was reached after $10^5$ s of averaging in an interleaved self-comparison of the clock.

preprint2015arXiv

Analysis of thermal radiation in ion traps for optical frequency standards

In many of the high-precision optical frequency standards with trapped atoms or ions that are under development to date, the AC Stark shift induced by thermal radiation leads to a major contribution to the systematic uncertainty. We present an analysis of the inhomogeneous thermal environment experienced by ions in various types of ion traps. Finite element models which allow the determination of the temperature of the trap structure and the temperature of the radiation were developed for 5 ion trap designs, including operational traps at PTB and NPL and further optimized designs. Models were refined based on comparison with infrared camera measurement until an agreement of better than 10% of the measured temperature rise at critical test points was reached. The effective temperature rises of the radiation seen by the ion range from 0.8 K to 2.1 K at standard working conditions. The corresponding fractional frequency shift uncertainties resulting from the uncertainty in temperature are in the 10-18 range for optical clocks based on the Sr+ and Yb+ E2 transitions, and even lower for Yb+ E3, In+ and Al+. Issues critical for heating of the trap structure and its predictability were identified and design recommendations developed.

preprint2014arXiv

Zeeman Slowers for Strontium based on Permanent Magnets

We present the design, construction, and characterisation of longitudinal- and transverse-field Zeeman slowers, based on arrays of permanent magnets, for slowing thermal beams of atomic Sr. The slowers are optimised for operation with deceleration related to the local laser intensity (by the parameter $ε$), which uses more effectively the available laser power, in contrast to the usual constant deceleration mode. Slowing efficiencies of up to $\approx$ $18$ $%$ are realised and compared to those predicted by modelling. We highlight the transverse-field slower, which is compact, highly tunable, light-weight, and requires no electrical power, as a simple solution to slowing Sr, well-suited to spaceborne application. For $^{88}$Sr we achieve a slow-atom flux of around $6\times 10^9$ atoms$\,$s$^{-1}$ at $30$ ms$^{-1}$, loading approximately $5\times 10^8$ atoms in to a magneto-optical-trap (MOT), and capture all isotopes in approximate relative natural abundances.

preprint2013arXiv

Robust frequency stabilization of multiple spectroscopy lasers with large and tunable offset frequencies

We demonstrate a compact and robust device for simultaneous absolute frequency stabilization of three diode lasers whose carrier frequencies can be chosen freely relative to the reference. A rigid ULE multi-cavity block is employed, and, for each laser, the sideband locking technique is applied. Useful features of the system are a negligible lock error, computer control of frequency offset, wide range of frequency offset, simple construction, and robust operation. One concrete application is as a stabilization unit for the cooling and trapping lasers of a neutral atom lattice clock. The device significantly supports and improves the operation of the clock. The laser with the most stringent requirements imposed by this application is stabilized to a linewidth of 70 Hz, and a residual frequency drift less than 0.5 Hz/s. The carrier optical frequency can be tuned over 350 MHz while in lock.

preprint2013arXiv

Suppression of amplitude-to-phase noise conversion in balanced optical-microwave phase detectors

We demonstrate an amplitude-to-phase (AM-PM) conversion coefficient for a balanced optical-microwave phase detector (BOM-PD) of 0.001 rad, corresponding to AM-PM induced phase noise 60 dB below the single-sideband relative intensity noise of the laser. This enables us to generate 8 GHz microwave signals from a commercial Er-fibre comb with a single-sideband residual phase noise of -131 dBc/Hz at 1 Hz offset frequency and -148 dBc/Hz at 1 kHz offset frequency.

preprint2011arXiv

Force-insensitive optical cavity

We describe a rigidly-mounted optical cavity which is insensitive to inertial forces acting in any direction and to the compressive force used to constrain it. The design is based on a cubic geometry with four supports placed symmetrically about the optical axis in a tetrahedral configuration. To measure the inertial force sensitivity, a laser is locked to the cavity while it is inverted about three orthogonal axes. The maximum acceleration sensitivity is 2.5\times10^-11/g (where g=9.81 ms^-2), the lowest passive sensitivity to be reported for an optical cavity.