Source author record

Paola Borri

Paola Borri appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

uFLIM -- Unsupervised analysis of FLIM-FRET microscopy data

Despite their widespread use in cell biology, fluorescence lifetime imaging microscopy (FLIM) data-sets are challenging to analyse, because each spatial position can contain a superposition of multiple fluorescent components. Here, we present a data analysis method employing all information in the available photon budget, as well as being fast. The method, called uFLIM, determines spatial distributions and temporal dynamics of multiple fluorescent components with no prior knowledge. It goes significantly beyond current approaches which either assume the functional dependence of the dynamics, e.g. an exponential decay, or require dynamics to be known, or calibrated. Its efficient non-negative matrix factorization algorithm allows for real-time data processing. We validate in silico that uFLIM is capable to disentangle the spatial distribution and spectral properties of five fluorescing probes, from only two excitation and detection channels and a photon budget of 100 detected photons per pixel. By adapting the method to data exhibiting Forster resonant energy transfer (FRET), we retrieve the spatial and transfer rate distribution of the bound species, without constrains on donor and acceptor dynamics.

preprint2021arXiv

Sizing individual dielectric nanoparticles with quantitative differential interference contrast microscopy

We report a method to measure the size of single dielectric nanoparticles with high accuracy and precision using quantitative differential interference contrast (DIC) microscopy. Dielectric nanoparticles are detected optically by the conversion of the optical phase change into an intensity change using DIC. Phase images of individual nanoparticles were retrieved from DIC by Wiener filtering, and a quantitative methodology to extract nanoparticle sizes was developed. Using polystyrene beads of 100 nm radius as size standard, we show that the method determines this radius within a few nm accuracy. The smallest detectable polystyrene bead is limited by background and shot-noise, which depend on acquisition and analysis parameters, including the objective numerical aperture, the DIC phase offset, and the refractive index contrast between particles and their surrounding. A sensitivity limit potentially reaching down to 1.8 nm radius was inferred. As application example, individual nanodiamonds with nominal sizes below 50 nm were measured, and were found to have a nearly exponential size distribution with 28 nm mean value. Considering the importance of dielectric nanoparticles in many fields, from naturally occurring virions to polluting nanoplastics, the proposed method could offer a powerful quantitative tool for nanoparticle analysis, combining accuracy, sensitivity and high-throughput with widely available and easy-to-use DIC microscopy

preprint2014arXiv

Evidence of giant oscillator strength in the exciton dephasing of CdSe nanoplatelets measured by resonant four-wave mixing

We measured the intrinsic ground-state exciton dephasing and population dynamics in colloidal quasi two-dimensional (2D) CdSe nanoplatelets at low temperature (5-50K) using transient resonant four-wave mixing in heterodyne detection. Our results indicate that below 20K the exciton dephasing is lifetime limited, with the exciton population lifetime being as fast as 1ps. This is consistent with an exciton lifetime given by a fast radiative decay due to the large in-plane coherence area of the exciton center-of-mass motion in these quasi 2D systems compared to spherical nanocrystals.

preprint2013arXiv

Polarization-resolved extinction and scattering cross-section of individual gold nanoparticles measured by wide-field microscopy on a large ensemble

We report a simple, rapid, and quantitative wide-field technique to measure the optical extinction $σ_{\rm ext}$ and scattering $σ_{\rm sca}$ cross-section of single nanoparticles using wide-field microscopy enabling simultaneous acquisition of hundreds of nanoparticles for statistical analysis. As a proof of principle, we measured nominally spherical gold nanoparticles of 40\,nm and 100\,nm diameter and found mean values and standard deviations of $σ_{\rm ext}$ and $σ_{\rm sca}$ consistent with previous literature. Switching from unpolarized to linearly polarized excitation, we measured $σ_{\rm ext}$ as a function of the polarization direction, and used it to characterize the asphericity of the nanoparticles. The method can be implemented cost-effectively on any conventional wide-field microscope and is applicable to any nanoparticles.

preprint2012arXiv

Femtosecond phase-resolved microscopy of plasmon dynamics in individual gold nanospheres

The selective optical detection of individual metallic nanoparticles (NPs) with high spatial and temporal resolution is a challenging endeavour, yet is key to the understanding of their optical response and their exploitation in applications from miniaturised optoelectronics and sensors to medical diagnostics and therapeutics. However, only few reports on ultrafast pump-probe spectroscopy on single small metallic NPs are available to date. Here, we demonstrate a novel phase-sensitive four-wave mixing (FWM) microscopy in heterodyne detection to resolve for the first time the ultrafast changes of real and imaginary part of the dielectric function of single small (<40nm) spherical gold NPs. The results are quantitatively described via the transient electron temperature and density in gold considering both intraband and interband transitions at the surface plasmon resonance. This novel microscopy technique enables background-free detection of the complex susceptibility change even in highly scattering environments and can be readily applied to any metal nanostructure.

preprint2011arXiv

Spin--flip Limited Exciton Dephasing in CdSe/ZnS Colloidal Quantum Dots

The dephasing time of the lowest bright exciton in CdSe/ZnS wurtzite quantum dots is measured from 5 K to 170 K and compared with density dynamics within the exciton fine structure using a sensitive three-beam four-wave-mixing technique unaffected by spectral diffusion. Pure dephasing via acoustic phonons dominates the initial dynamics, followed by an exponential zero-phonon line dephasing of 109 ps at 5 K, much faster than the ~10 ns exciton radiative lifetime. The zero-phonon line dephasing is explained by phonon-assisted spin-flip from the lowest bright state to dark exciton states. This is confirmed by the temperature dependence of the exciton lifetime and by direct measurements of the bright-dark exciton relaxation. Our results give an unambiguous evidence of the physical origin of the exciton dephasing in these nanocrystals.