Source author record

Pablo Yepes

Pablo Yepes appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2021arXiv

Optimization of FLASH Proton Beams Using a Track-Repeating Algorithm

Methods: A phase space file in a plane at 202 mm downstream of the beam exit window is generated through tuning parameters to match FDC results with measured or MCNPX Monte Carlo-simulated integrated depth-dose distribution (IDD) and lateral dose profiles. To spread out the Bragg peak, widen the beam and reduce the penumbra, a ridge filter (RF), a high-Z material scatterer and a collimator with compensator are inserted in the beam path and their shapes and sizes have been optimized. The FDC calculations are validated by comparing Geant4 Monte Carlo simulations. In addition, a set of algorithms to automatically choose the optimum dimensions of the beam shaping elements is developed and tested using the same beams. At the last part, dose rates for optimized beams were estimated by scaling their dose distributions to that of their original beams. Results: The optimized 86.4 MeV beam had an 8.5 mm wide spread-out Bragg peak (SOBP) (proximal 90% to distal 90% of the maximum dose), 14.5 mm, 12.0 mm and 11.0 lateral widths with dose above 50%, 80% and 90% respectively and a 2.5 mm penumbra from 80% to 20% in the lateral profile for the energy. The 159.5 MeV beam had a SOBP of 39.0 mm and the lateral widths with dose above 50%, 80% and 90% of 20.5 mm, 15.0 and 12.5 mm when the source to surface distance (SSD) was 550 mm. Wider lateral widths was obtained with increased SSD. The FDC calculations had passing rates higher than 96% using 3mm/3% as the gamma-index criterion comparing with Geant4 simulations for both energies. The set of automatic algorithms can choose the proper dimensions for the high-density scatterer, RF, collimator and compensator efficiently. And the optimized 159.5 MeV beam with different SDDs had entrance dose rate higher than 40 Gy/s if the entrance dose rate of the original beam was 150 Gy/s.

preprint2014arXiv

Ultra-Intense Gamma-Rays Created Using the Texas Petawatt Laser

In a series of experiments at the Texas Petawatt Laser (TPW) in Austin, TX, we have used attenuation spectrometers, dosimeters, and a new Forward Compton Electron Spectrometer (FCES) to measure and characterize the angular distribution, fluence, and energy spectrum of the X-rays and gamma rays produced by the TPW striking multi-millimeter thick gold targets. Our results represent the first such measurements at laser intensities > 10 21 W*cm-2 and pulse durations < 150 fs. We obtain a maximum yield of X-ray and gamma ray energy with respect to laser energy of 4% and a mean yield of 2%. We futher obtain a Full Width Half Maximum (FWHM) of the gamma distribution of 37°. We were able to characterize the gamma-ray spectrum from 3 MeV to 90 MeV using a Forward Compton Electron Spectrometer, with an energy resolution of 0.5 MeV and mean kT of ~ 6 MeV.. We were able to characterize the spectrum from 1 to 7 MeV using a Filter Stack Spectrometer, measuring a mean gamma-ray temperature for the spectrum from 3 to 7 MeV of 2.1 MeV.

preprint2011arXiv

Scaling of Laser Produced Pair Plasmas And Comparison With Experimental Data

We report simulation results of pair production by ultra-intense lasers irradiating a gold target using the GEANT4 Monte-Carlo code. Certain experimental features of the positron and electron energy spectra are reproduced, as well as trends with regard to target thickness and hot electron temperature Te. For Te in the range 5-10 MeV, the optimal target thickness for pair production is found to be about 3 mm. Further Monte-Carlo simulations may aid in the optimization of laser-driven positron sources.