Researcher profile

P. Freeman

P. Freeman contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

Properties of HPK UFSD after neutron irradiation up to 6e15 n/cm2

In this paper we report results from a neutron irradiation campaign of Ultra-Fast Silicon Detectors (UFSD) with fluences of 1e14, 3e14, 6e14, 1e15, 3e15, 6e15 n/cm2. The UFSD used in this study are circular 50 micro-meter thick Low-Gain Avalanche Detectors (LGAD), with a 1.0 mm diameter active area. They have been produced by Hamamatsu Photonics (HPK), Japan, with pre-radiation internal gain in the range 10-100 depending on the bias voltage. The sensors were tested pre-irradiation and post-irradiation with minimum ionizing particle (MIPs) from a 90Sr based \b{eta}-source. The leakage current, internal gain and the timing resolution were measured as a function of bias voltage at -20C and -30C. The timing resolution was extracted from the time difference with a second calibrated UFSD in coincidence, using the constant fraction method for both. The dependence of the gain upon the irradiation fluence is consistent with the concept of acceptor removal and the gain decreases from about 80 pre-irradiation to 7 after a fluence of 6e15 n/cm2. Consequently, the timing resolution was found to deteriorate from 20 ps to 50 ps. The results indicate that the most accurate time resolution is obtained at a value of the constant fraction discriminator (CFD) threshold used to determine the time of arrival varying with fluence, from 10% pre-radiation to 60% at the highest fluence. Key changes to the pulse shape induced by irradiation, i.e. (i) a reduce sensitivity of the pulse shape on the initial non-uniform charge deposition, (ii) the shortening of the rise time and (iii) the reduced pulse height, were compared with the WF2 simulation program and found to be in agreement.

preprint2019arXiv

Mini-MALTA: Radiation hard pixel designs for small-electrode monolithic CMOS sensors for the High Luminosity LHC

Depleted Monolithic Active Pixel Sensor (DMAPS) prototypes developed in the TowerJazz 180 nm CMOS imaging process have been designed in the context of the ATLAS upgrade Phase-II at the HL-LHC. The pixel sensors are characterized by a small collection electrode (3 $μ$m) to minimize capacitance, a small pixel size ($36.4\times 36.4$ $μ$m), and are produced on high resistivity epitaxial p-type silicon. The design targets a radiation hardness of $1\times10^{15}$ 1 MeV n$_{eq}$/cm$^{2}$, compatible with the outermost layer of the ATLAS ITK Pixel detector. This paper presents the results from characterization in particle beam tests of the Mini-MALTA prototype that implements a mask change or an additional implant to address the inefficiencies on the pixel edges. Results show full efficiency after a dose of $1\times10^{15}$ 1 MeV n$_{eq}$/cm$^{2}$.

preprint2003arXiv

Chandra Multi-wavelength Project (ChaMP). I. First X-ray Source Catalog

The Chandra Multi-wavelength Project (ChaMP) is a wide-area (~14 deg^2) survey of serendipitous Chandra X-ray sources, aiming to establish fair statistical samples covering a wide range of characteristics (such as absorbed AGNs, high z clusters of galaxies) at flux levels (fX ~ 10^-15 - 10^-14 erg sec-1 cm-2) intermediate between the Chandra Deep surveys and previous missions. We present the first ChaMP catalog, which consists of 991 near on-axis, bright X-ray sources obtained from the initial sample of 62 observations. The data have been uniformly reduced and analyzed with techniques specifically developed for the ChaMP and then validated by visual examination. To assess source reliability and positional uncertainty, we perform a series of simulations and also use Chandra data to complement the simulation study. The false source detection rate is found to be as good as or better than expected for a given limiting threshold. On the other hand, the chance of missing a real source is rather complex, depending on the source counts, off-axis distance (or PSF), and background rate. The positional error (95% confidence level) is usually < 1&#34; for a bright source, regardless of its off-axis distance while it can be as large as 4&#34; for a weak source (~20 counts) at a large off-axis distance (Doff-axis > 8&#39;). We have also developed new methods to find spatially extended or temporary variable sources and those sources are listed in the catalog.

preprint2003arXiv

Chandra Multi-wavelength Project (ChaMP). II. First Results of X-ray Source Properties

We present the first results of ChaMP X-ray source properties obtained from the initial sample of 62 observations. The data have been uniformly reduced and analyzed with techniques specifically developed for the ChaMP and then validated by visual examination. Utilizing only near on-axis, bright X-ray sources (to avoid problems caused by incompleteness and the Eddington bias), we derive the Log(N)-Log(S) relation in soft (0.5-2 keV) and hard (2-8 keV) energy bands. The ChaMP data are consistent with previous results of ROSAT, ASCA and Chandra deep surveys. In particular, our data nicely fill in the flux gap in the hard band between the Chandra Deep Field data and the previous ASCA data. We check whether there is any systematic difference in the source density between cluster and non-cluster fields and also search for field-to-field variations, both of which have been previously reported. We found no significant field-to-field cosmic variation in either test within the statistics (~1 sigma) across the flux levels included in our sample. In the X-ray color-color plot, most sources fall in the location characterized by photon index = 1.5-2 and NH = a few x 10^20 cm^2, suggesting that they are typical broad-line AGNs. There also exist a considerable number of sources with peculiar X-ray colors (e.g., highly absorbed, very hard, very soft). We confirm a trend that on average the X-ray color hardens as the count rate decreases. Since the hardening is confined to the softest energy band (0.3-0.9 keV), we conclude it is most likely due to absorption. We cross-correlate the X-ray sources with other catalogs and describe their properties in terms of optical color, X-ray-to-optical luminosity ratio and X-ray colors.