Source author record

Olivier Daigle

Olivier Daigle appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2020arXiv

Delta-doped Electron Multiplying CCDs for FIREBall-2

We present the status of on-going detector development efforts for our joint NASA/CNES balloon-borne UV multi-object spectrograph, the Faint Intergalactic Redshifted Emission Balloon (FIREBall-2; FB-2). FB-2 demonstrates a new UV detector technology, the delta-doped Electron Multiplying CCD (EMCCD), in a low risk suborbital environment, to prove the performance of EMCCDs for future space missions and Technology Readiness Level (TRL) advancement. EMCCDs can be used in photon counting (PC) mode to achieve extremely low readout noise ($<$1 electron). Our testing has focused on reducing clock-induced-charge (CIC) through wave shaping and well depth optimization with a \nuvu V2 CCCP Controller, measuring CIC at 0.001 e$^{-}$/pixel/frame. This optimization also includes methods for reducing dark current, via cooling, and substrate voltage levels. We discuss the challenges of removing cosmic rays, which are also amplified by these detectors, as well as a data reduction pipeline designed for our noise measurement objectives. FB-2 flew in 2018, providing the first time an EMCCD was used for UV observations in the stratosphere. FB-2 is currently being built up to fly again in 2020, and improvements are being made to the EMCCD to continue optimizing its performance for better noise control.

preprint2013arXiv

The Brazilian Tunable Filter Imager for the SOAR telescope

This paper presents a new Tunable Filter Instrument for the SOAR telescope. The Brazilian Tunable Filter Imager (BTFI) is a versatile, new technology, tunable optical imager to be used in seeing-limited mode and at higher spatial fidelity using the SAM Ground-Layer Adaptive Optics facility at the SOAR telescope. The instrument opens important new science capabilities for the SOAR community, from studies of the centers of nearby galaxies and the insterstellar medium to statistical cosmological investigations. The BTFI takes advantage of three new technologies. The imaging Bragg Tunable Filter concept utilizes Volume Phase Holographic Gratings in a double-pass configuration, as a tunable filter, while a new Fabry-Perot (FP) concept involves technologies which allow a single FP etalon to act over a large range of interference orders and spectral resolutions. Both technologies will be in the same instrument. Spectral resolutions spanning the range between 25 and 30,000 can be achieved through the use of iBTF at low resolution and scanning FPs beyond R ~2,000. The third new technologies in BTFI is the use of EMCCDs for rapid and cyclically wavelength scanning thus mitigating the damaging effect of atmospheric variability through data acquisition. An additional important feature of the instrument is that it has two optical channels which allow for the simultaneous recording of the narrow-band, filtered image with the remaining (complementary) broad-band light. This avoids the uncertainties inherent in tunable filter imaging using a single detector. The system was designed to supply tunable filter imaging with a field-of-view of 3 arcmin on a side, sampled at 0.12" for direct Nasmyth seeing-limited area spectroscopy and for SAM's visitor instrument port for GLAO-fed area spectroscopy. The instrument has seen first light, as a SOAR visitor instrument. It is now in comissioning phase.

preprint2009arXiv

Extreme faint flux imaging with an EMCCD

An EMCCD camera, designed from the ground up for extreme faint flux imaging, is presented. CCCP, the CCD Controller for Counting Photons, has been integrated with a CCD97 EMCCD from e2v technologies into a scientific camera at the Laboratoire d'Astrophysique Expérimentale (LAE), Université de Montréal. This new camera achieves sub-electron read-out noise and very low Clock Induced Charge (CIC) levels, which are mandatory for extreme faint flux imaging. Data gathered with the camera suggests that through enhanced manufacturing processes, which would avoid traps from being created, and with the help of the clock shapes producible with CCCP, the CIC generated during the vertical transfer could be virtually suppressed. The camera has been characterized in laboratory and used on the Observatoire du Mont Mégantic 1.6-m telescope. The performance of the camera is discussed and experimental data with the first scientific data are presented.