Source author record

Jean-Luc Gach

Jean-Luc Gach appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

C-BLUE 3 PC : a photon counting multimegapixel visible CMOS camera

The photon counting imaging paradigm in the visible and the infrared comes from the very small energy carried by a single photon at these wavelengths. Usually to detect photons the photoelectric effect is used. It converts a photon to a single electron making it very difficult to detect because of the readout noise of the electronics. To overcome this there are two strategies, either to amplify the signal to make it larger than the readout noise (used in the so called gain or amplified detectors), or to lower the readout noise in a standard image sensor. For a long time, only amplified detectors were able to do some photon counting. Since the first photon counting systems in the visible, developed by Boksenberg and his collaborators in 1972, many groups around the world improved photon counting techniques. In the 2000's in the visible, EMCCDs (electron multiplying charge coupled devices) allowed to replace the classical image intensifier photon counting systems by solid state devices and improved a lot the QE. But EMCCDs suffer from several issues, and the most important of them is the excess noise factor which prevents to know the exact incoming number of photons in the case of multiple photons per pixel. In the infrared there was no equivalent to EMCCDs up to the development of e-APD sensors and cameras made with HgCdTe material (electron initiated avalanche photo diode). With an excess noise factor near 1 at low temperatures, photon counting is possible with these devices but only in the infrared. We will show that having excess noise factor prevents from being able to do multiple photon counting (quanta imaging) and the only solution is to lower the readout noise.

preprint2022arXiv

Last performances improvement of the C-RED One camera using the 320x256 e-APD infrared Saphira detector

We present here the latest results obtained with the C-RED One camera developed by First Light Imaging for fast ultra-low noise infrared applications. This camera uses the Leonardo Saphira e-APD 320x256 infrared sensor in an autonomous cryogenic environment with a low vibration pulse tube and with embedded readout electronics system. Some recent improvements were made to the camera. The first important one concerns the total noise of the camera. Limited to 1.75 microns wavelength cut-off with proper cold filters, looking at a blackbody at room temperature and f/4 beam aperture, we now measure total noise down to 0.6 e at gain 50 in CDS mode 1720 FPS, dividing previous noise figure by a factor 2. The total camera background of 30-400 e/s is now achieved with a factor 3 of background reduction, the camera also looking at a room temperature blackbody with an F/4 beam aperture. Image bias oscillations, due to electronics grounding scheme, were carefully analyzed and removed. Focal plane detector vibrations transmitted by the pulse tube cooling machine were also analyzed, damped and measured down to 0.3 microns RMS, reducing focal plane vibrations by a factor 3. In addition, a vacuum getter of higher capacity is now used to offer camera operation without camera pumping during months. The camera main characteristics are detailed: pulse tube cooling at 80K with limited vibrations, permanent vacuum solution, ultra-low latency Cameralink full data interface, safety management of the camera by firmware, online firmware update, ambient liquid cooling and reduced weight of 20 kg.

preprint2022arXiv

Sub-electron noise infrared camera development using Leonardo large format 2Kx2K SWIR LmAPD array

There have been no significant breakthroughs in infrared imagery since the hybridization of III-V or II-VI narrow-bandgap semiconductors on complementary metal-oxide semiconductor (CMOS) read-out integrated circuits (ROICs). The development of third-generation, linear-mode avalanche photodiode arrays (LmAPDs) using mercury cadmium telluride (MCT) has resulted in a significant sensitivity improvement for short-wave infrared (SWIR) imaging. The first dedicated LmAPD device, called SAPHIRA (320x256/24 microns), was designed by Leonardo UK Ltd specifically for SWIR astronomical applications. In the past decade there has been a significant development effort to make larger LmAPD arrays for low-background astronomy. Larger LmAPD formats for ultra-low noise/flux SWIR imaging, currently under development at Leonardo include a 512 x 512 LmAPD array funded by ESO, MPE and NRC Herzberg, a 1k x 1k array funded by NASA and a 2K x 2K device funded by ESA for general scientific imaging applications. The 2048x2048 pixel ROIC has a pitch of 15 microns, 4/8/16 outputs and a maximum frame rate of 10 Hz. The ROIC characterization is scheduled in the third quarter of 2022, while the first arrays will be fabricated by end-2022. The hybridized arrays will be characterized during end-2022. At this time, First Light Imaging will start the development of an autonomous camera integrating this 2Kx2K LmAPD array, based on the unique experience from the C-RED One camera, the only commercial camera integrating the SAPHIRA SWIR LmAPD array.The detector will be embedded in a compact high vacuum cryostat cooled with low vibration pulse at 50-80K which does not require external pumping. Sub-electron readout noise is expected to be achieved with high multiplication gain. Custom cold filters and beam aperture cold baffling will be integrated in the camera.

preprint2013arXiv

The Brazilian Tunable Filter Imager for the SOAR telescope

This paper presents a new Tunable Filter Instrument for the SOAR telescope. The Brazilian Tunable Filter Imager (BTFI) is a versatile, new technology, tunable optical imager to be used in seeing-limited mode and at higher spatial fidelity using the SAM Ground-Layer Adaptive Optics facility at the SOAR telescope. The instrument opens important new science capabilities for the SOAR community, from studies of the centers of nearby galaxies and the insterstellar medium to statistical cosmological investigations. The BTFI takes advantage of three new technologies. The imaging Bragg Tunable Filter concept utilizes Volume Phase Holographic Gratings in a double-pass configuration, as a tunable filter, while a new Fabry-Perot (FP) concept involves technologies which allow a single FP etalon to act over a large range of interference orders and spectral resolutions. Both technologies will be in the same instrument. Spectral resolutions spanning the range between 25 and 30,000 can be achieved through the use of iBTF at low resolution and scanning FPs beyond R ~2,000. The third new technologies in BTFI is the use of EMCCDs for rapid and cyclically wavelength scanning thus mitigating the damaging effect of atmospheric variability through data acquisition. An additional important feature of the instrument is that it has two optical channels which allow for the simultaneous recording of the narrow-band, filtered image with the remaining (complementary) broad-band light. This avoids the uncertainties inherent in tunable filter imaging using a single detector. The system was designed to supply tunable filter imaging with a field-of-view of 3 arcmin on a side, sampled at 0.12" for direct Nasmyth seeing-limited area spectroscopy and for SAM's visitor instrument port for GLAO-fed area spectroscopy. The instrument has seen first light, as a SOAR visitor instrument. It is now in comissioning phase.

preprint2009arXiv

Extreme faint flux imaging with an EMCCD

An EMCCD camera, designed from the ground up for extreme faint flux imaging, is presented. CCCP, the CCD Controller for Counting Photons, has been integrated with a CCD97 EMCCD from e2v technologies into a scientific camera at the Laboratoire d'Astrophysique Expérimentale (LAE), Université de Montréal. This new camera achieves sub-electron read-out noise and very low Clock Induced Charge (CIC) levels, which are mandatory for extreme faint flux imaging. Data gathered with the camera suggests that through enhanced manufacturing processes, which would avoid traps from being created, and with the help of the clock shapes producible with CCCP, the CIC generated during the vertical transfer could be virtually suppressed. The camera has been characterized in laboratory and used on the Observatoire du Mont Mégantic 1.6-m telescope. The performance of the camera is discussed and experimental data with the first scientific data are presented.