Source author record

O. D. Petrenko

O. D. Petrenko appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2021arXiv

Recent advancements of the experiment to search for $2K$-capture in $^{124}$Xe using a Large Low-background Proportional Counter

A new method for correcting the charge signal from the large proportional counter is proposed. The correction method makes it possible to take into account the loss of primary ionization electrons in the presence of weakly increasing micro impurities of electronegative gases during long-term measurements. It allows increasing the efficiency of the selection of useful events and thereby increasing the sensitivity to $2\nu2K$-decay in $^{124}$Xe at the level of $2\times10^{22}$ from over six years of measurements using a large proportional counter. Analysis of the calibration data, taking into account the new method for correcting the energy release in the detector, made it possible to register events from double $K$ photoionization by a single photon.

preprint2020arXiv

Annual variations of the $^{214}$Po, $^{213}$Po and $^{212}$Po half-life values

Results of a comparative analysis of the $^{214}$Po ($T_{1/2}= 163.47\pm0.03$ $μ$s), $^{213}$Po ($T_{1/2}=3.705 \pm 0.001$ $μ$s) and $^{212}$Po ($T_{1/2}=294.09\pm0.07$ ns) half-life annular variation parameters are presented. It is shown that two independent sequential sets of the $^{214}$Po $τ$-values $(τ\equiv T_{1/2})$ obtained in the spaced laboratories can be described by sinusoidal functions. The sinusoid curve with amplitude $A=(5.0 \pm1.5) \cdot 10^{-4}$, period $ω=(365\pm 8)$ days, and phase $ϕ=(170 \pm 7)$ days approximates the set of $^{214}$Po $τ$ values obtained at BNO INR RAS during the $\sim$973 days starting on January 4, 2012. The function approximates a set of $τ$-values with a time duration of $\sim1460$ days obtained at the KhNU has an amplitude $A=(4.9\pm1.8)\cdot10^{-4}$, a period $ω= (377\pm13)$ days and a phase $ϕ=(77\pm10)$ days. The $^{213}$Po $τ$-value set with a time duration of $\sim1700$ days can be described by a sinusoidal function with an amplitude $A=(3.9\pm1.2)\cdot10^{-4}$, a period $ω= (370\pm13)$ days and a phase $ϕ=(130\pm9)$ days. The $^{212}$Po $τ$-value set with a time duration of $\sim670$ days can be described by a sinusoidal function with an amplitude $A=(7.5\pm1.6)\cdot10^{-4}$, a period $ω= (375\pm13)$ days and a phase $ϕ=(40\pm10)$ days.

preprint2018arXiv

The background simulation of experiment for searching of $2\nu2K$ capture in Xe-124

We describe the Monte Carlo (MC) simulation package of the `2K-CAPTURE' setup and discuss the agreement of its output with data. The `2K-CAPTURE' MC simulates the energy loss of particles in detector and components of the passive shield and generates the resulting response in working volume large proportional counter (LPC). The simulation accounts for absorption, reemission, and scattering of both photons and neutrons and tracks them until they either are absorbed. The algorithm proceeds with a detailed simulation of the electronics chain. The MC is tuned using data collected with radioactive calibration source deployed in the internal channel of the installation. The simulation reproduces the energy response of the detector corresponding to distribution of the generated pointwise clusters of a charge of primary ionization in LPC.