Source author record

Niklaus Berger

Niklaus Berger appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

10works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2022arXiv

Characterization of a continuous muon source for the Muon-Induced X-ray Emission (MIXE) Technique

The toolbox for material characterization has never been richer than today. Great progress with all kinds of particles and interaction methods provide access to nearly all properties of an object under study. However, a tomographic analysis of the subsurface region remains still a challenge today. In this regard, the Muon-Induced X-ray Emission (MIXE) technique has seen rebirth fueled by the availability of high intensity muon beams. We report here a study conducted at the Paul Scherrer Institute (PSI). It demonstrates that the absence of any beam time-structure leads to low pile-up events and a high signal-to-noise ratio (SNR) with less than one hour acquisition time per sample or data point. This performance creates the perspective to open this technique to a wider audience for the routine investigation of non-destructive and depth-sensitive elemental compositions, for example in rare and precious samples. Using a hetero-structured sample of known elements and thicknesses, we successfully detected the characteristic muonic X-rays, emitted during the capture of a negative muon by an atom, and the gamma-rays resulting from the nuclear capture of the muon, characterizing the capabilities of MIXE at PSI. This sample emphasizes the quality of a continuous beam, and the exceptional SNR at high rates. Such sensitivity will enable totally new statistically intense aspects in the field of MIXE, e.g. elemental 3D-tomography and chemical analysis. Therefore, we are currently advancing our proof-of-concept experiments with the goal of creating a full fledged permanently operated user station to make MIXE available to the wider scientific community as well as industry.

preprint2022arXiv

muEDM: Towards a search for the muon electric dipole moment at PSI using the frozen-spin technique

The search for a permanent electric dipole moment (EDM) of the muon is an excellent probe for physics beyond the Standard Model of particle physics. We propose the first dedicated muon EDM search employing the frozen-spin technique at the Paul Scherrer Institute (PSI), Switzerland, with a sensitivity of $6 \times 10^{-23}~e\!\cdot\!\mathrm{cm}$, improving the current best limit set by the E821 experiment at Brookhaven National Laboratory by more than three orders of magnitude. In preparation for a high precision experiment to measure the muon EDM, several R&D studies have been performed at PSI: the characterisation of a possible beamline to host the experiment for the muon beam injection study and the measurement of the multiple Coulomb scattering of positrons in potential detector materials at low momenta for the positron tracking scheme development. This paper discusses experimental concepts and the current status of the muEDM experiment at PSI.

preprint2016arXiv

A New Three-Dimensional Track Fit with Multiple Scattering

Modern semiconductor detectors allow for charged particle tracking with ever increasing position resolution. Due to the reduction of the spatial hit uncertainties, multiple Coulomb scattering in the detector layers becomes the dominant source for tracking uncertainties. In this case long distance effects can be ignored for the momentum measurement, and the track fit can consequently be formulated as a sum of independent fits to hit triplets. In this paper we present an analytical solution for a three-dimensional triplet(s) fit in a homogeneous magnetic field based on a multiple scattering model. Track fitting of hit triplets is performed using a linearization ansatz. The momentum resolution is discussed for a typical spectrometer setup. Furthermore the track fit is compared with other track fits for two different pixel detector geometries, namely the Mu3e experiment at PSI and a typical high-energy collider experiment. For a large momentum range the triplets fit provides a significantly better performance than a single helix fit. The triplets fit is fast and can easily be parallelized, which makes it ideal for the implementation on parallel computing architectures.

preprint2016arXiv

The MuPix System-on-Chip for the Mu3e Experiment

Mu3e is a novel experiment searching for charged lepton flavor violation in the rare decay $μ^+ \rightarrow e^+e^-e^+$. Decay vertex position, decay time and particle momenta have to be precisely measured in order to reject both accidental and physics background. A silicon pixel tracker based on $50\,μ$m thin high voltage monolithic active pixel sensors (HV-MAPS) in a 1 T solenoidal magnetic field provides precise vertex and momentum information. The MuPix chip combines pixel sensor cells with integrated analog electronics and a periphery with a complete digital readout. The MuPix7 is the first HV-MAPS prototype implementing all functionalities of the final sensor including a readout state machine and high speed serialization with 1.25 Gbit/s data output, allowing for a streaming readout in parallel to the data taking. The observed efficiency of the MuPix7 chip including the full readout system is $\geq99\%$ in a high rate test beam.

preprint2015arXiv

Measuring the weak mixing angle with the P2 experiment at MESA

The P2 experiment in Mainz aims to measure the weak mixing angle in electron- proton scattering to a precision of 0.13 %. In order to suppress uncertainties due to proton structure and contributions from box graphs, both a low average momentum transfer $Q^2$ of $4.5\cdot 10^{-3}$ GeV$^2/c^2$ and a low beam energy of 155 MeV are chosen. In order to collect the enormous statistics required for this measurement, the new Mainz Energy Recovery Superconducting Accelerator (MESA) is being constructed. These proceedings describe the motivation for the measurement, the experimental and accelerator challenges and how we plan to tackle them.

preprint2014arXiv

Multiple Coulomb Scattering in Thin Silicon

We present a measurement of multiple Coulomb scattering of 1 to 6 GeV/c electrons in thin (50-140 um) silicon targets. The data were obtained with the EUDET telescope Aconite at DESY and are compared to parametrisations as used in the Geant4 software package. We find good agreement between data and simulation in the scattering distribution width but large deviations in the shape of the distribution. In order to achieve a better description of the shape, a new scattering model based on a Student's t distribution is developed and compared to the data.

preprint2013arXiv

A Tracker for the Mu3e Experiment based on High-Voltage Monolithic Active Pixel Sensors

The Mu3e experiment searches for the lepton flavour violating decay mu+ -> e+e-e+, aiming for a branching fraction sensitivity of 10^-16. This requires an excellent momentum resolution for low energy electrons, high rate capability and a large acceptance. In order to minimize multiple scattering, the amount of material has to be as small as possible. These challenges can be met with a tracker built from high-voltage monolithic active pixel sensors (HV-MAPS), which can be thinned to 50 um and which incorporate the complete read-out electronics on the sensor chip. To further minimise material, the sensors are supported by a mechanical structure built from 25 um thick Kapton foil and cooled with gaseous helium.

preprint2011arXiv

A novel experiment searching for the lepton flavour violating decay mu -> eee

Since the discovery of neutrino oscillations it is known that lepton flavour is not conserved. Lepton flavour violating processes in the charged lepton sector have so far however eluded detection; as they are heavily suppressed in the standard model of particle physics, an observation would be a clear signal for new physics and help to understand the source of neutrino masses and CP violation. We propose a novel experiment searching for the decay mu -> eee with the aim of ultimately reaching a sensitivity of 10^-16, an improvement by four orders of magnitude compared to previous experiments. The technologies enabling this step are thin high-voltage monolithic active pixel sensors for precise tracking at high rates with a minimum of material and scintillating fibres for high resolution time measurements.

preprint2011arXiv

Partial wave analysis at BES III harnessing the power of GPUs

Partial wave analysis is a core tool in hadron spectroscopy. With the high statistics data available at facilities such as the Beijing Spectrometer III, this procedure becomes computationally very expensive. We have successfully implemented a framework for performing partial wave analysis on graphics processors. We discuss the implementation, the parallel computing frameworks employed and the performance achieved, with a focus on the recent transition to the OpenCL framework.

preprint2011arXiv

Partial Wave Analysis using Graphics Cards

Partial wave analysis is a key technique in hadron spectroscopy. The use of unbinned likelihood fits on large statistics data samples and ever more complex physics models makes this analysis technique computationally very expensive. Parallel computing techniques, in particular the use of graphics processing units, are a powerful means to speed up analyses; in the contexts of the BES III, Compass and GlueX experiments, parallel analysis frameworks have been created. They provide both fits that are faster by more than two orders of magnitude than legacy code and environments to quickly program and run an analysis. This in turn allows the physicists to focus on the many difficult open problems pertaining to partial wave analysis.