Source author record

N. Poli

N. Poli appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

15works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

15 published item(s)

preprint2022arXiv

High-power, frequency-quadrupled UV laser source resonant with the $^{1}$S$_{0}$-$^{3}$P$_{1}$ narrow intercombination transition of cadmium at 326.2 nm

We present a novel high-power, frequency-stabilized UV laser source at 326.2~nm, resonant with the Cd $^{1}$S$_{0}$ - $^{3}$P$_{1}$ narrow intercombination transition. We have achieved a maximum produced power of 1~W at 326.2~nm by two successive frequency doubling stages of a narrow-linewidth (< 1~kHz) seed laser at 1304.8~nm. About 3.4 W of optical power at 652.4 nm is produced by a visible Raman fiber amplifier (VRFA) that amplifies and generates the second harmonic of the infrared radiation. The visible light is subsequently frequency-doubled down to 326.2~nm in a non-linear bow-tie cavity using a Brewster-cut beta-barium-borate (BBO) crystal, with a maximum conversion efficiency of around 40$\%$ for 2.5~W coupled red power. Full characterization of the laser source, together with spectroscopy signals of all Cd isotopes, spanning more than 4 GHz in the UV, are shown.

preprint2015arXiv

Development of a strontium optical lattice clock for the SOC mission on the ISS

Ultra-precise optical clocks in space will allow new studies in fundamental physics and astronomy. Within an European Space Agency (ESA) program, the Space Optical Clocks (SOC) project aims to install and to operate an optical lattice clock on the International Space Station (ISS) towards the end of this decade. It would be a natural follow-on to the ACES mission, improving its performance by at least one order of magnitude. The payload is planned to include an optical lattice clock, as well as a frequency comb, a microwave link, and an optical link for comparisons of the ISS clock with ground clocks located in several countries and continents. Within the EU-FP7-SPACE-2010-1 project no. 263500, during the years 2011-2015 a compact, modular and robust strontium lattice optical clock demonstrator has been developed. Goal performance is a fractional frequency instability below 1x10^{-15}, tau^{-1/2} and a fractional inaccuracy below 5x10^{-17}. Here we describe the current status of the apparatus' development, including the laser subsystems. Robust preparation of cold {88}^Sr atoms in a second stage magneto-optical trap (MOT) is achieved.

preprint2015arXiv

Large-momentum-transfer Bragg interferometer with strontium atoms

We report on the first atom interferometer based on Bragg diffraction in a fountain of alkaline-earth atoms, namely $^{88}$Sr. We demonstrate large momentum transfer to the atoms up to eight photon recoils and the use of the interferometer as a gravimeter with a sensitivity $δg/g=4\times 10^{-8}$. Thanks to the special characteristics of strontium atoms for precision measurements, this result opens a new way for experiments in fundamental and applied physics.

preprint2014arXiv

A transportable strontium optical lattice clock

We report on a transportable optical clock, based on laser-cooled strontium atoms trapped in an optical lattice. The experimental apparatus is composed of a compact source of ultra-cold strontium atoms including a compact cooling laser set-up and a transportable ultra-stable laser for interrogating the optical clock transition. The whole setup (excluding electronics) fits within a volume of less than 2 m$^3$. The high degree of operation reliability of both systems allowed the spectroscopy of the clock transition to be performed with 10 Hz resolution. We estimate an uncertainty of the clock of $7\times10^{-15}$.

preprint2014arXiv

Coherent optical frequency transfer at 5e-19 over a doubled 642 km fiber link

To significantly improve the frequency references used in radio-astronomy and precision measurements in atomic physics, we provide frequency dissemination through a 642 km coherent optical fiber link, that will be also part of a forthcoming European network of optical links. We obtained a resolution of 3e-19 at 1000 s on the frequency transfer, and an accuracy of 5e-19. The ultimate link performance has been evaluated by doubling the link to 1284 km, demonstrating a new characterization technique based on the double round-trip on a single fiber. The arming of a second fiber is avoided: this is beneficial to long hauls realizations in view of a continental fiber network for frequency and time metrology. The data analysis is based on the Allan deviation; its expression is theoretically derived for the observed noise power spectrum, which is seldom found in the literature.

preprint2014arXiv

Optical atomic clocks

In the last ten years extraordinary results in time and frequency metrology have been demonstrated. Frequency-stabilization techniques for continuous-wave lasers and femto-second optical frequency combs have enabled a rapid development of frequency standards based on optical transitions in ultra-cold neutral atoms and trapped ions. As a result, today's best performing atomic clocks tick at an optical rate and allow scientists to perform high-resolution measurements with a precision approaching a few parts in $10^{18}$. This paper reviews the history and the state of the art in optical-clock research and addresses the implementation of optical clocks in a possible future redefinition of the SI second as well as in tests of fundamental physics.

preprint2014arXiv

Test of Einstein Equivalence Principle for 0-spin and half-integer-spin atoms: Search for spin-gravity coupling effects

We report on a conceptually new test of the equivalence principle performed by measuring the acceleration in Earth's gravity field of two isotopes of strontium atoms, namely, the bosonic $^{88}$Sr isotope which has no spin vs the fermionic $^{87}$Sr isotope which has a half-integer spin. The effect of gravity upon the two atomic species has been probed by means of a precision differential measurement of the Bloch frequency for the two atomic matter waves in a vertical optical lattice. We obtain the values $η= (0.2\pm 1.6)\times10^{-7}$ for the Eötvös parameter and $k=(0.5\pm1.1)\times10^{-7}$ for the coupling between nuclear spin and gravity. This is the first reported experimental test of the equivalence principle for bosonic and fermionic particles and opens a new way to the search for the predicted spin-gravity coupling effects.

preprint2012arXiv

Delocalization-enhanced Bloch oscillations and driven resonant tunneling in optical lattices for precision force measurements

In this paper we describe and compare different methods used for accurate determination of forces acting on matter-wave packets in optical lattices. The quantum interference nature responsible for the production of both Bloch oscillations and coherent delocalization is investigated in detail. We study conditions for optimal detection of Bloch oscillation for a thermal ensemble of cold atoms with a large velocity spread. We report on the experimental observation of resonant tunneling in an amplitude-modulated (AM) optical lattice up to the sixth harmonic with Fourier-limited linewidth. We then explore the fundamental and technical phenomena which limit both the sensitivity and the final accuracy of the atomic force sensor at 10^{-7} precision level [1], with an analysis of the coherence time of the system and addressing few simple setup changes to go beyond the current accuracy.

preprint2012arXiv

The Space Optical Clocks Project: Development of high-performance transportable and breadboard optical clocks and advanced subsystems

The use of ultra-precise optical clocks in space ("master clocks") will allow for a range of new applications in the fields of fundamental physics (tests of Einstein's theory of General Relativity, time and frequency metrology by means of the comparison of distant terrestrial clocks), geophysics (mapping of the gravitational potential of Earth), and astronomy (providing local oscillators for radio ranging and interferometry in space). Within the ELIPS-3 program of ESA, the "Space Optical Clocks" (SOC) project aims to install and to operate an optical lattice clock on the ISS towards the end of this decade, as a natural follow-on to the ACES mission, improving its performance by at least one order of magnitude. The payload is planned to include an optical lattice clock, as well as a frequency comb, a microwave link, and an optical link for comparisons of the ISS clock with ground clocks located in several countries and continents. Undertaking a necessary step towards optical clocks in space, the EU-FP7-SPACE-2010-1 project no. 263500 (SOC2) (2011-2015) aims at two "engineering confidence", accurate transportable lattice optical clock demonstrators having relative frequency instability below 1\times10^-15 at 1 s integration time and relative inaccuracy below 5\times10^-17. This goal performance is about 2 and 1 orders better in instability and inaccuracy, respectively, than today's best transportable clocks. The devices will be based on trapped neutral ytterbium and strontium atoms. One device will be a breadboard. The two systems will be validated in laboratory environments and their performance will be established by comparison with laboratory optical clocks and primary frequency standards. In this paper we present the project and the results achieved during the first year.

preprint2010arXiv

Precision measurement of gravity with cold atoms in an optical lattice and comparison with a classical gravimeter

We report on a high precision measurement of gravitational acceleration using ultracold strontium atoms trapped in a vertical optical lattice. Using amplitude modulation of the lattice intensity, an uncertainty $Δg /g \approx 10^{-7}$ was reached by measuring at the 5$^{th}$ harmonic of the Bloch oscillation frequency. After a careful analysis of systematic effects, the value obtained with this microscopic quantum system is consistent with the one we measured with a classical absolute gravimeter at the same location. This result is of relevance for the recent interpretation of related experiments as tests of gravitational redshift and opens the way to new tests of gravity at micrometer scale.

preprint2008arXiv

A simplified optical lattice clock

Existing optical lattice clocks demonstrate a high level of performance, but they remain complex experimental devices. In order to address a wider range of applications including those requiring transportable devices, it will be necessary to simplify the laser systems and reduce the amount of support hardware. Here we demonstrate two significant steps towards this goal: demonstration of clock signals from a Sr lattice clock based solely on semiconductor laser technology, and a method for finding the clock transition (based on a coincidence in atomic wavelengths) that removes the need for extensive frequency metrology hardware. Moreover, the unexpected high contrast in the signal revealed evidence of density dependent collisions in Sr-88 atoms.

preprint2006arXiv

Direct demonstration of decoupling of spin and charge currents in nanostructures

The notion of decoupling of spin and charge currents is one of the basic principles underlying the rapidly expanding feld of Spintronics. However, no direct demonstration of the phenomenon exists. We report a novel measurement, in which a non-equilibrium spin population is created by a point-like injection of current from a ferromagnet across a tunnel barrier into a one dimensional spin channel, and detected differentially by a pair of ferromagnetic electrodes placed symmetrically about the injection point. We demonstrate that the spin current is strictly isotropic about the injection point and, therefore, completely decoupled from the uni-directional charge current.

preprint2006arXiv

Enhanced spin accumulation in a superconductor

A lateral array of ferromagnetic tunnel junctions is used to inject and detect non-equilibrium quasi-particle spin distribution in a superconducting strip made of Al. The strip width and thickness is kept below the quasi particle spin diffusion length in Al. Non-local measurements in multiple parallel and antiparallel magnetic states of the detectors are used to in-situ determine the quasi-particle spin diffusion length. A very large increase in the spin accumulation in the superconducting state compared to that in the normal state is observed and is attributed to a diminishing of the quasi-particle population by opening of the gap below the transition temperature.

preprint2006arXiv

Spin flip scattering at Al surfaces

Non-local measurements are performed on a multi terminal device to $in-situ$ determine the spin diffusion length and in combination with resistivity measurements also the spin relaxation time in Al films. By varying the thickness of Al we determine the contribution to spin relaxation from surface scattering. From the temperature dependence of the spin diffusion length it is established that the spin relaxation is impurity dominated at low temperature. A comparison of the spin and momentum relaxation lengths for different thicknesses reveals that the spin flip scattering at the surfaces is weak compared to that within the bulk of the Al films.