Source author record

N. Nouri

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

5works
2topics
4close collaborators

Published work

5 publications

preprint2019arXiv

Final results for the neutron ββ-asymmetry parameter A0A_0 from the UCNA experiment

The UCNA experiment was designed to measure the neutron ββ-asymmetry parameter A0A_0 using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for A0A_0 was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for A0A_0.

preprint2019arXiv

Improved limits on Fierz Interference using asymmetry measurements from the UCNA experiment

The Ultracold Neutron Asymmetry (UCNA) experiment was designed to measure the ββ-decay asymmetry parameter, A0A_0, for free neutron decay. In the experiment, polarized ultracold neutrons are transported into a decay trap, and their ββ-decay electrons are detected with ≈4π\approx 4π acceptance into two detector packages which provide position and energy reconstruction. The experiment also has sensitivity to bnb_{n}, the Fierz interference term in the neutron ββ-decay rate. In this work, we determine bnb_{n} from the energy dependence of A0A_0 using the data taken during the UCNA 2011-2013 run. In addition, we present the same type of analysis using the earlier 2010 AA dataset. Motivated by improved statistics and comparable systematic errors compared to the 2010 data-taking run, we present a new bnb_{n} measurement using the weighted average of our asymmetry dataset fits, to obtain bn=0.066±0.041stat±0.024systb_{n} = 0.066 \pm 0.041_{\text{stat}} \pm 0.024_{\text{syst}} which corresponds to a limit of −0.012<bn<0.144-0.012 < b_{n} < 0.144 at the 90% confidence level.

preprint2019arXiv

The neutron electric dipole moment experiment at the Spallation Neutron Source

Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarized 3^3He, and superfluid 4^4He will be exploited to provide a sensitivity to ∼10−28 e ⋅ cm\sim 10^{-28}\,e{\rm \,\cdot\, cm}. Our cryogenic apparatus will deploy two small (3 L3\,{\rm L}) measurement cells with a high density of ultracold neutrons produced and spin analyzed in situ. The electric field strength, precession time, magnetic shielding, and detected UCN number will all be enhanced compared to previous room temperature Ramsey measurements. Our 3^3He co-magnetometer offers unique control of systematic effects, in particular the Bloch-Siegert induced false EDM. Furthermore, there will be two distinct measurement modes: free precession and dressed spin. This will provide an important self-check of our results. Following five years of "critical component demonstration," our collaboration transitioned to a "large scale integration" phase in 2018. An overview of our measurement techniques, experimental design, and brief updates are described in these proceedings.

preprint2013arXiv

Comparison of magnetic field uniformities for discretized and finite-sized standard cos⁡θ\cosθ, solenoidal, and spherical coils

A significant challenge for experiments requiring a highly uniform magnetic field concerns the identification and design of a discretized and finite-sized magnetic field coil of minimal size. In this work we compare calculations of the magnetic field uniformities and field gradients for three different standard (i.e., non-optimized) types of coils: cos⁡θ\cosθ, solenoidal, and spherical coils. For an experiment with a particular requirement on either the field uniformity or the field gradient, we show that the volume required by a spherical coil form which satisfies these requirements can be significantly less than the volumes required by cos⁡θ\cosθ and solenoidal coil forms.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.