Source author record

N. I. Gidopoulos

N. I. Gidopoulos appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2016arXiv

A local Fock-exchange potential in Kohn-Sham equations

We derive and employ a local potential to represent the Fock exchange operator in electronic single-particle equations. This local Fock-exchange (LFX) potential is very similar to the exact exchange (EXX) potential in density functional theory (DFT). The practical software implementation of the two potentials (LFX and EXX) yields robust and accurate results for a variety of systems (semiconductors, transition metal oxides) where Hartree Fock and popular approximations of DFT typically fail. This includes examples traditionally considered qualitatively inaccessible to calculations that omit correlation.

preprint2010arXiv

Comment on "High energy neutron scattering from hydrogen using a direct geometry spectrometer". C. Stock, R A Cowley, J W Taylor and S M Bennington [arXiv:0907.1945]

The paper in the title [1] reports measurements of neutron scattering from hydrogen in the 1-100 eV range of energy transfers, using the direct geometry MARI spectrometer at ISIS. Stock et al claim that their measurements have better or comparable energy resolution to those on the inverse geometry VESUVIO spectrometer at ISIS. Most importantly the main conclusions of ref [1] are not valid unless this claim is true: in particular the conclusion that anomalous neutron cross sections measured on VESUVIO [2] are "the result of experimental issues using indirect geometry spectrometers". We present here overwhelming evidence that the energy resolution of the measurements in ref [1] is much coarser than on VESUVIO. It follows that the conclusions of Stock et al are unfounded. In reality the measurements of reference [1] serve mainly to demonstrate that at eV neutron energies, direct geometry chopper spectrometers have greatly inferior energy resolution to inverse geometry spectrometers based on resonance foil methods.