Researcher profile

Murat Kuscu

Murat Kuscu contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2023arXiv

Frequency-Domain Detection for Molecular Communications

Molecular Communications (MC) is a bio-inspired communication paradigm which uses molecules as information carriers, thereby requiring unconventional transmitter/receiver architectures and modulation/detection techniques. Practical MC receivers (MC-Rxs) can be implemented based on field-effect transistor biosensor (bioFET) architectures, where surface receptors reversibly react with ligands, whose concentration encodes the information. The time-varying concentration of ligand-bound receptors is then translated into electrical signals via field-effect, which is used to decode the transmitted information. However, ligand-receptor interactions do not provide an ideal molecular selectivity, as similar types of ligands, i.e., interferers, co-existing in the MC channel can interact with the same type of receptors, resulting in cross-talk. Overcoming this molecular cross-talk with time-domain samples of the Rx's electrical output is not always attainable, especially when Rx has no knowledge of the interferer statistics or it operates near saturation. In this study, we propose a frequency-domain detection (FDD) technique for bioFET-based MC-Rxs, which exploits the difference in binding reaction rates of different types of ligands, reflected to the noise spectrum of the ligand-receptor binding fluctuations. We analytically derive the bit error probability (BEP) of the FDD technique, and demonstrate its effectiveness in decoding transmitted concentration signals under stochastic molecular interference, in comparison to a widely-used time-domain detection (TDD) technique. The proposed FDD method can be applied to any biosensor-based MC-Rxs, which employ receptor molecules as the channel-Rx interface.

preprint2023arXiv

Microfluidic Pulse Shaping Methods for Molecular Communications

Molecular Communication (MC) is a bio-inspired communication modality that utilizes chemical signals in the form of molecules to exchange information between spatially separated entities. Pulse shaping is an important process in all communication systems, as it modifies the waveform of transmitted signals to match the characteristics of the communication channel for reliable and high-speed information transfer. In MC systems, the unconventional architectures of components, such as transmitters and receivers, and the complex, nonlinear, and time-varying nature of MC channels make pulse shaping even more important. While several pulse shaping methods have been theoretically proposed for MC, their practicality and performance are still uncertain. Moreover, the majority of recently proposed experimental MC testbeds that rely on microfluidics technology lack the incorporation of programmable pulse shaping methods, which hinders the accurate evaluation of MC techniques in practical settings. To address the challenges associated with pulse shaping in microfluidic MC systems, we provide a comprehensive overview of practical microfluidic chemical waveform generation techniques that have been experimentally validated and whose architectures can inform the design of pulse shaping methods for microfluidic MC systems and testbeds. These techniques include those based on hydrodynamic and acoustofluidic force fields, as well as electrochemical reactions. We also discuss the fundamental working mechanisms and system architectures of these techniques, and compare their performances in terms of spatiotemporal resolution, selectivity, system complexity, and other performance metrics relevant to MC applications, as well as their feasibility for practical MC applications.

preprint2022arXiv

Capacity Analysis of Molecular Communications with Ratio Shift Keying Modulation

Molecular Communications (MC) is a bio-inspired communication technique that uses molecules to encode and transfer information. Many efforts have been focused on developing new modulation techniques for MC by exploiting distinguishable properties of molecules. In this paper, we investigate a particular modulation scheme where the information is encoded into the concentration ratio of two different types of molecules. To evaluate the performance of this so-called Ratio Shift Keying (RSK) modulation, we carry out an information theoretical analysis and derive the capacity of the end-to-end MC channel where the receiver performs ratio estimation based on ligand-receptor binding statistics in an optimal or suboptimal manner. The numerical results, obtained for varying similarity between the ligand types employed for ratio-encoding, and number of receptors, indicate that the RSK can outperform the concentration shift keying (CSK) modulation, the most common technique considered in literature, when the transmitter is power-limited. The results also indicate the potential advantages of RSK over other modulation methods under time-varying channel conditions, when the effects of the dynamic conditions are invariant to the type of the molecules.

preprint2022arXiv

Internet of Everything (IoE) -- From Molecules to the Universe

The universe is a vast heterogeneous network of interconnected entities that continuously generate and exchange information through various forms of interactions, some of which are yet to be discovered. Internet of Everything (IoE) framework, inspired by the ubiquitous and adaptive connectivity and the seamless interoperability within this universal network, puts forward a new road map beyond the conventional Internet of Things (IoT) towards maximizing the resolution of our interface with the universe to enable unprecedented applications. The first pillar of this road map is to reveal novel and tangible interconnections between seemingly noninteracting branches of IoT, which we call IoXs with X referring to their application domains, e.g., Internet of Energy (IoEn), Internet of Vehicles (IoV). The second pillar is to develop new IoXs that can complement the existing ones to complete the overall IoE picture and match its networking traits to that of the universe for a seamless and all-embracing cyber-physical interface. The objective of this paper is to evaluate the potential of this holistic IoE approach to expand the limited application landscape of the current IoT practice on a scale ranging $\textit{from molecules to the universe}$. To this end, we identify several potential interaction pathways among IoXs and introduce novel and emerging IoXs that are essential to the comprehensiveness of IoE. We also discuss the potential applications that can be enabled by such interconnections within the IoE framework and identify the associated challenges.

preprint2020arXiv

Graphene-based Nanoscale Molecular Communication Receiver: Fabrication and Microfluidic Analysis

Bio-inspired molecular communications (MC), where molecules are used to transfer information, is the most promising technique to realise the Internet of Nano Things (IoNT), thanks to its inherent biocompatibility, energy-efficiency, and reliability in physiologically-relevant environments. Despite a substantial body of theoretical work concerning MC, the lack of practical micro/nanoscale MC devices and MC testbeds has led researchers to make overly simplifying assumptions about the implications of the channel conditions and the physical architectures of the practical transceivers in developing theoretical models and devising communication methods for MC. On the other hand, MC imposes unique challenges resulting from the highly complex, nonlinear, time-varying channel properties that cannot be always tackled by conventional information and communication tools and technologies (ICT). As a result, the reliability of the existing MC methods, which are mostly adopted from electromagnetic communications and not validated with practical testbeds, is highly questionable. As the first step to remove this discrepancy, in this study, we report on the fabrication of a nanoscale MC receiver based on graphene field-effect transistor biosensors. We perform its ICT characterisation in a custom-designed microfluidic MC system with the information encoded into the concentration of single-stranded DNA molecules. This experimental platform is the first practical implementation of a micro/nanoscale MC system with nanoscale MC receivers, and can serve as a testbed for developing realistic MC methods and IoNT applications.