Source author record

Miguel O. Bernabeu

Miguel O. Bernabeu appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

13works
16topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

13 published item(s)

preprint2022arXiv

Detection of multiple retinal diseases in ultra-widefield fundus images using deep learning: data-driven identification of relevant regions

Ultra-widefield (UWF) imaging is a promising modality that captures a larger retinal field of view compared to traditional fundus photography. Previous studies showed that deep learning (DL) models are effective for detecting retinal disease in UWF images, but primarily considered individual diseases under less-than-realistic conditions (excluding images with other diseases, artefacts, comorbidities, or borderline cases; and balancing healthy and diseased images) and did not systematically investigate which regions of the UWF images are relevant for disease detection. We first improve on the state of the field by proposing a DL model that can recognise multiple retinal diseases under more realistic conditions. We then use global explainability methods to identify which regions of the UWF images the model generally attends to. Our model performs very well, separating between healthy and diseased retinas with an area under the curve (AUC) of 0.9206 on an internal test set, and an AUC of 0.9841 on a challenging, external test set. When diagnosing specific diseases, the model attends to regions where we would expect those diseases to occur. We further identify the posterior pole as the most important region in a purely data-driven fashion. Surprisingly, 10% of the image around the posterior pole is sufficient for achieving comparable performance to having the full images available.

preprint2022arXiv

Robust and efficient computation of retinal fractal dimension through deep approximation

A retinal trait, or phenotype, summarises a specific aspect of a retinal image in a single number. This can then be used for further analyses, e.g. with statistical methods. However, reducing an aspect of a complex image to a single, meaningful number is challenging. Thus, methods for calculating retinal traits tend to be complex, multi-step pipelines that can only be applied to high quality images. This means that researchers often have to discard substantial portions of the available data. We hypothesise that such pipelines can be approximated with a single, simpler step that can be made robust to common quality issues. We propose Deep Approximation of Retinal Traits (DART) where a deep neural network is used predict the output of an existing pipeline on high quality images from synthetically degraded versions of these images. We demonstrate DART on retinal Fractal Dimension (FD) calculated by VAMPIRE, using retinal images from UK Biobank that previous work identified as high quality. Our method shows very high agreement with FD VAMPIRE on unseen test images (Pearson r=0.9572). Even when those images are severely degraded, DART can still recover an FD estimate that shows good agreement with FD VAMPIRE obtained from the original images (Pearson r=0.8817). This suggests that our method could enable researchers to discard fewer images in the future. Our method can compute FD for over 1,000img/s using a single GPU. We consider these to be very encouraging initial results and hope to develop this approach into a useful tool for retinal analysis.

preprint2021arXiv

Euler Characteristic Surfaces

We study the use of the Euler characteristic for multiparameter topological data analysis. Euler characteristic is a classical, well-understood topological invariant that has appeared in numerous applications, including in the context of random fields. The goal of this paper is to present the extension of using the Euler characteristic in higher-dimensional parameter spaces. While topological data analysis of higher-dimensional parameter spaces using stronger invariants such as homology continues to be the subject of intense research, Euler characteristic is more manageable theoretically and computationally, and this analysis can be seen as an important intermediary step in multi-parameter topological data analysis. We show the usefulness of the techniques using artificially generated examples, and a real-world application of detecting diabetic retinopathy in retinal images.

preprint2020arXiv

Automated Segmentation of Optical Coherence Tomography Angiography Images: Benchmark Data and Clinically Relevant Metrics

Optical coherence tomography angiography (OCTA) is a novel non-invasive imaging modality for the visualisation of microvasculature in vivo that has encountered broad adoption in retinal research. OCTA potential in the assessment of pathological conditions and the reproducibility of studies relies on the quality of the image analysis. However, automated segmentation of parafoveal OCTA images is still an open problem. In this study, we generate the first open dataset of retinal parafoveal OCTA images with associated ground truth manual segmentations. Furthermore, we establish a standard for OCTA image segmentation by surveying a broad range of state-of-the-art vessel enhancement and binarisation procedures. We provide the most comprehensive comparison of these methods under a unified framework to date. Our results show that, for the set of images considered, deep learning architectures (U-Net and CS-Net) achieve the best performance. For applications where manually segmented data is not available to retrain these approaches, our findings suggest that optimal oriented flux is the best handcrafted filter from those considered. Furthermore, we report on the importance of preserving network structure in the segmentation to enable deep vascular phenotyping. We introduce new metrics for network structure evaluation in segmented angiograms. Our results demonstrate that segmentation methods with equal Dice score perform very differently in terms of network structure preservation. Moreover, we compare the error in the computation of clinically relevant vascular network metrics (e.g. foveal avascular zone area and vessel density) across segmentation methods. Our results show up to 25% differences in vessel density accuracy depending on the segmentation method employed. These findings should be taken into account when comparing the results of clinical studies and performing meta-analyses.

preprint2020arXiv

Spatio-temporal dynamics of dilute red blood cell suspensions in a microchannel flow at low Reynolds number

Microfluidic technologies are commonly used for the manipulation of red blood cell (RBC) suspensions and analyses of flow-mediated biomechanics. To enhance the performance of microfluidic devices, understanding the dynamics of the suspensions processed within is crucial. We report novel aspects of the spatio-temporal dynamics of RBC suspensions flowing through a typical microchannel at low Reynolds number. Through experiments with dilute RBC suspensions, we find an off-centre two-peak (OCTP) profile of cells contrary to the centralised distribution commonly reported for low-inertia flows. This is reminiscent of the well-known "tubular pinch effect" which arises from inertial effects. However, given the conditions of negligible inertia in our experiments, an alternative explanation is needed for this OCTP profile. Our massively-parallel simulations of RBC flow in real-size microfluidic dimensions using the immersed-boundary-lattice-Boltzmann method (IB-LBM) confirm the experimental findings and elucidate the underlying mechanism for the counterintuitive RBC pattern. By analysing the RBC migration and cell-free layer (CFL) development within a high-aspect-ratio channel, we show that such a distribution is co-determined by the spatial decay of hydrodynamic lift and the global deficiency of cell dispersion in dilute suspensions. We find a CFL development length greater than 46 and 28 hydraulic diameters in the experiment and simulation, respectively, exceeding typical lengths of microfluidic designs. Our work highlights the key role of transient cell distribution in dilute suspensions, which may negatively affect the reliability of experimental results if not taken into account.

preprint2015arXiv

An automated multiscale ensemble simulation approach for vascular blood flow

Cerebrovascular diseases such as brain aneurysms are a primary cause of adult disability. The flow dynamics in brain arteries, both during periods of rest and increased activity, are known to be a major factor in the risk of aneurysm formation and rupture. The precise relation is however still an open field of investigation. We present an automated ensemble simulation method for modelling cerebrovascular blood flow under a range of flow regimes. By automatically constructing and performing an ensemble of multiscale simulations, where we unidirectionally couple a 1D solver with a 3D lattice-Boltzmann code, we are able to model the blood flow in a patient artery over a range of flow regimes. We apply the method to a model of a middle cerebral artery, and find that this approach helps us to fine-tune our modelling techniques, and opens up new ways to investigate cerebrovascular flow properties.

preprint2014arXiv

Computer simulations reveal complex distribution of haemodynamic forces in a mouse retina model of angiogenesis

There is currently limited understanding of the role played by haemodynamic forces on the processes governing vascular development. One of many obstacles to be overcome is being able to measure those forces, at the required resolution level, on vessels only a few micrometres thick. In the current paper, we present an in silico method for the computation of the haemodynamic forces experienced by murine retinal vasculature (a widely used vascular development animal model) beyond what is measurable experimentally. Our results show that it is possible to reconstruct high-resolution three-dimensional geometrical models directly from samples of retinal vasculature and that the lattice-Boltzmann algorithm can be used to obtain accurate estimates of the haemodynamics in these domains. We generate flow models from samples obtained at postnatal days (P) 5 and 6. Our simulations show important differences between the flow patterns recovered in both cases, including observations of regression occurring in areas where wall shear stress gradients exist. We propose two possible mechanisms to account for the observed increase in velocity and wall shear stress between P5 and P6: i) the measured reduction in typical vessel diameter between both time points, ii) the reduction in network density triggered by the pruning process. The methodology developed herein is applicable to other biomedical domains where microvasculature can be imaged but experimental flow measurements are unavailable or difficult to obtain.

preprint2014arXiv

Impact of blood rheology on wall shear stress in a model of the middle cerebral artery

Perturbations to the homeostatic distribution of mechanical forces exerted by blood on the endothelial layer have been correlated with vascular pathologies including intracranial aneurysms and atherosclerosis. Recent computational work suggests that in order to correctly characterise such forces, the shear-thinning properties of blood must be taken into account. To the best of our knowledge, these findings have never been compared against experimentally observed pathological thresholds. In the current work, we apply the three-band diagram (TBD) analysis due to Gizzi et al. to assess the impact of the choice of blood rheology model on a computational model of the right middle cerebral artery. Our results show that, in the model under study, the differences between the wall shear stress predicted by a Newtonian model and the well known Carreau-Yasuda generalized Newtonian model are only significant if the vascular pathology under study is associated with a pathological threshold in the range 0.94 Pa to 1.56 Pa, where the results of the TBD analysis of the rheology models considered differs. Otherwise, we observe no significant differences.

preprint2014arXiv

Weighted decomposition in high-performance lattice-Boltzmann simulations: are some lattice sites more equal than others?

Obtaining a good load balance is a significant challenge in scaling up lattice-Boltzmann simulations of realistic sparse problems to the exascale. Here we analyze the effect of weighted decomposition on the performance of the HemeLB lattice-Boltzmann simulation environment, when applied to sparse domains. Prior to domain decomposition, we assign wall and in/outlet sites with increased weights which reflect their increased computational cost. We combine our weighted decomposition with a second optimization, which is to sort the lattice sites according to a space filling curve. We tested these strategies on a sparse bifurcation and very sparse aneurysm geometry, and find that using weights reduces calculation load imbalance by up to 85%, although the overall communication overhead is higher than some of our runs.

preprint2013arXiv

Analyzing and Modeling the Performance of the HemeLB Lattice-Boltzmann Simulation Environment

We investigate the performance of the HemeLB lattice-Boltzmann simulator for cerebrovascular blood flow, aimed at providing timely and clinically relevant assistance to neurosurgeons. HemeLB is optimised for sparse geometries, supports interactive use, and scales well to 32,768 cores for problems with ~81 million lattice sites. We obtain a maximum performance of 29.5 billion site updates per second, with only an 11% slowdown for highly sparse problems (5% fluid fraction). We present steering and visualisation performance measurements and provide a model which allows users to predict the performance, thereby determining how to run simulations with maximum accuracy within time constraints.

preprint2013arXiv

Choice of boundary condition for lattice-Boltzmann simulation of moderate Reynolds number flow in complex domains

Modeling blood flow in larger vessels using lattice-Boltzmann methods comes with a challenging set of constraints: a complex geometry with walls and inlet/outlets at arbitrary orientations with respect to the lattice, intermediate Reynolds number, and unsteady flow. Simple bounce-back is one of the most commonly used, simplest, and most computationally efficient boundary conditions, but many others have been proposed. We implement three other methods applicable to complex geometries (Guo, Zheng and Shi, Phys Fluids (2002); Bouzdi, Firdaouss and Lallemand, Phys. Fluids (2001); Junk and Yang Phys. Rev. E (2005)) in our open-source application \HemeLB{}. We use these to simulate Poiseuille and Womersley flows in a cylindrical pipe with an arbitrary orientation at physiologically relevant Reynolds (1--300) and Womersley (4--12) numbers and steady flow in a curved pipe at relevant Dean number (100--200) and compare the accuracy to analytical solutions. We find that both the Bouzidi-Firdaouss-Lallemand and Guo-Zheng-Shi methods give second-order convergence in space while simple bounce-back degrades to first order. The BFL method appears to perform better than GZS in unsteady flows and is significantly less computationally expensive. The Junk-Yang method shows poor stability at larger Reynolds number and so cannot be recommended here. The choice of collision operator (lattice Bhatnagar-Gross-Krook vs.\ multiple relaxation time) and velocity set (D3Q15 vs.\ D3Q19 vs.\ D3Q27) does not significantly affect the accuracy in the problems studied.

preprint2013arXiv

Flexible composition and execution of high performance, high fidelity multiscale biomedical simulations

Multiscale simulations are essential in the biomedical domain to accurately model human physiology. We present a modular approach for designing, constructing and executing multiscale simulations on a wide range of resources, from desktops to petascale supercomputers, including combinations of these. Our work features two multiscale applications, in-stent restenosis and cerebrovascular bloodflow, which combine multiple existing single-scale applications to create a multiscale simulation. These applications can be efficiently coupled, deployed and executed on computers up to the largest (peta) scale, incurring a coupling overhead of 1 to 10% of the total execution time.

preprint2012arXiv

Coalesced communication: a design pattern for complex parallel scientific software

We present a new design pattern for high-performance parallel scientific software, named coalesced communication. This pattern allows for a structured way to improve the communication performance through coalescence of multiple communication needs using two communication management components. We apply the design pattern to several simulations of a lattice-Boltzmann blood flow solver with streaming visualisation which engenders a reduction in the communication overhead of approximately 40%.