Researcher profile

Michele Gianella

Michele Gianella contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

High-Resolution Quantum Cascade Laser Dual-Comb Spectroscopy in the Mid-Infrared with Absolute Frequency Referencing

Quantum cascade laser (QCL) frequency combs have revolutionized mid-infrared (MIR) spectroscopy by their high brightness and fast temporal resolution, and are a promising technology for fully-integrated and cost-effective sensors. As for other integrated comb sources such as micro-combs and interband cascade laser, QCLs have a comb spacing of several GHz, which is adequate for measurements of wide absorbing structures, typically found in liquid or solid samples. However, high-resolution gas-phase spectra require spectral interleaving and frequency calibration. We developed a frequency calibration scheme for fast interleaved measurements with combs featuring multi-GHz spacing. We then demonstrate dual-comb spectroscopy with 600 kHz accuracy in single-shot 54-ms measurements over 40 cm$^{-1}$ using two QCLs at 7.8 $\mathrmμ$m. This work is an important contribution towards fast fingerprinting of complex molecular mixtures in the MIR. Moreover, the calibration scheme could be used with micro-combs for spectroscopy and ranging, both in comb-swept and comb-calibrated setups.

preprint2019arXiv

High-resolution and gapless dual comb spectroscopy with current-tuned quantum cascade lasers

We present gapless, high-resolution absorption and dispersion spectra obtained with quantum cascade laser frequency combs covering 55 cm$^{-1}$. Using phase-sensitive dual comb design, the comb lines are gradually swept over 10 GHz, corresponding to the free spectral range of the laser devices, by applying a current modulation. We show that with interleaving the spectral point spacing is reduced by more than four orders of magnitude over the full spectral span of the frequency comb. The potential of this technique for high-precision gas sensing is illustrated by measuring the low pressure (107 hPa) absorption and dispersion spectra of methane spanning the range of 1170 cm$^{-1}$ - 1225 cm$^{-1}$ with a resolution of 0.001 cm$^{-1}$.