Source author record

Michel Lours

Michel Lours appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

9works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2016arXiv

Frequency tripled 1542 nm telecom laser diode stabilized to iodine hyperfine line in the 10-15 range

We report on telecom laser frequency stabilization to narrow iodine hyperfine line in the green range of the optical domain, after a frequency tripling process using two nonlinear PPLN crystals. We have generated up to 300 mW optical power in the green (P3w), from 800 mW of infrared power (Pw). This result corresponds to an optical conversion efficiency eta= P3w/Pw ~ 36 %. To our knowledge, this is the best value ever demonstrated for a CW frequency tripling process. We have used a narrow linewidth iodine hyperfine line (component a1 of the 127I2 R 35 (44-0) line) to stabilize the IR laser yielding to frequency stability of 4.8x10-14 t-1/2 with a minimum of 6x10-15 reached after 50 s of integration time. The whole optical setup is very compact and mostly optically fibered. This approach opens the way for efficient and elegant architecture development for space applications as one of several potential uses.

preprint2014arXiv

A compact micro-wave synthesizer for transportable cold-atom interferometers

We present the realization of a compact micro-wave frequency synthesizer for an atom interferometer based on stimulated Raman transitions, applied to transportable inertial sensing. Our set-up is intended to address the hyperfine transitions of Rubidium 87 atoms at 6.8 GHz. The prototype is evaluated both in the time and the frequency domain by comparison with state-of-the-art frequency references developed at LNE-SYRTE. In free-running mode, it features a residual phase noise level of -65 dBrad$^2.Hz^{-1} at 10-Hz offset frequency and a white phase noise level in the order of -120 dBrad^2.Hz^{-1} for Fourier frequencies above 10 kHz. The phase noise effect on the sensitivity of the atomic interferometer is evaluated for diverse values of cycling time, interrogation time and Raman pulse duration. To our knowledge, the resulting contribution is well below the sensitivity of any demonstrated cold atom inertial sensors based on stimulated Raman transitions. The drastic improvement in terms of size, simplicity and power consumption paves the way towards field and mobile operations.

preprint2014arXiv

A simple laser system for atom interferometry

We present here a simple laser system for a laser cooled atom interferometer, where all functions (laser cooling, interferometry and detection) are realized using only two extended cavity laser diodes, amplified by a common tapered amplifier. One laser is locked by frequency modulation transfer spectroscopy, the other being phase locked with an offset frequency determined by an Field-Programmable Gate Array (FPGA) controlled Direct Digital Synthesizer (DDS), which allows for efficient and versatile tuning of the laser frequency. Raman lasers are obtained with a double pass acousto-optic modulator. We demonstrate a gravimeter using this laser system, with performances close to the state of the art.

preprint2014arXiv

Dick effect in a pulsed atomic clock using Coherent Population Trapping

The Dick effect can be a limitation of the achievable frequency stability of a passive atomic frequency standard when the ancillary frequency source is only periodically sampled. Here we analyze the Dick effect for a pulsed vapor cell clock using coherent population trapping (CPT). Due to its specific interrogation process without atomic preparation nor detection outside of the Ramsey pulses, it exhibits an original shape of the sensitivity function to phase noise of the oscillator. Numerical calculations using a three-level atom model are successfully compared with measurements; an approximate formula of the sensitivity function is given as an easy-to-use tool. A comparison of our CPT clock sensitivity to phase noise with a clock of the same duty cycle using a two-level system reveals a higher sensitivity in the CPT case. The influence of a free-evolution time variation and of a detection duration lengthening on this sensitivity is studied. Finally this study permitted to choose an adapted quartz oscillator and allowed an improvement of the clock fractional frequency stability at the level of 3.2x10-13 at 1s

preprint2014arXiv

Hybridizing matter-wave and classical accelerometers

We demonstrate a hybrid accelerometer that benefits from the advantages of both conventional and atomic sensors in terms of bandwidth (DC to 430 Hz) and long term stability. First, the use of a real time correction of the atom interferometer phase by the signal from the classical accelerometer enables to run it at best performances without any isolation platform. Second, a servo-lock of the DC component of the conventional sensor output signal by the atomic one realizes a hybrid sensor. This method paves the way for applications in geophysics and in inertial navigation as it overcomes the main limitation of atomic accelerometers, namely the dead times between consecutive measurements.

preprint2014arXiv

Optical phase locking of two infrared CW lasers separated by 100 THz

We report on phase-locking of two continuous wave infrared laser sources separated by 100 THz emitting around 1029 nm and 1544 nm respectively. Our approach uses three independent harmonic generation processes of the IR laser frequencies in periodically poled MgO: LiNbO3 crystals to generate second and third harmonic of that two IR sources. The beat note between the two independent green radiations generated around 515 nm is used to phase-lock one IR laser to the other, with tunable radio frequency offset. In this way, the whole setup operates as a mini frequency comb (MFC) emitting four intense optical radiations (1544 nm, 1029 nm, 772 nm and 515 nm), with output powers at least 3 orders of magnitude higher than the available power from each mode emitted by femtosecond lasers.

preprint2012arXiv

Progress in Atomic Fountains at LNE-SYRTE

We give an overview of the work done with the Laboratoire National de Métrologie et d'Essais-Systèmes de Référence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest developments, we review recent studies of several systematic frequency shifts. This includes the distributed cavity phase shift, which we evaluate for the FO1 and FOM fountains, applying the techniques of our recent work on FO2. We also report calculations of the microwave lensing frequency shift for the three fountains, review the status of the blackbody radiation shift, and summarize recent experimental work to control microwave leakage and spurious phase perturbations. We give current accuracy budgets. We also describe several applications in time and frequency metrology: fountain comparisons, calibrations of the international atomic time, secondary representation of the SI second based on the 87Rb hyperfine frequency, absolute measurements of optical frequencies, tests of the T2L2 satellite laser link, and review fundamental physics applications of the LNE-SYRTE fountain ensemble. Finally, we give a summary of the tests of the PHARAO cold atom space clock performed using the FOM transportable fountain.

preprint2011arXiv

Detecting inertial effects with airborne matter-wave interferometry

Inertial sensors relying on atom interferometry offer a breakthrough advance in a variety of applications, such as inertial navigation, gravimetry or ground- and space-based tests of fundamental physics. These instruments require a quiet environment to reach their performance and using them outside the laboratory remains a challenge. Here we report the first operation of an airborne matter-wave accelerometer set up aboard a 0g plane and operating during the standard gravity (1g) and microgravity (0g) phases of the flight. At 1g, the sensor can detect inertial effects more than 300 times weaker than the typical acceleration fluctuations of the aircraft. We describe the improvement of the interferometer sensitivity in 0g, which reaches 2 x 10-4 ms-2 / \surdHz with our current setup. We finally discuss the extension of our method to airborne and spaceborne tests of the Universality of free fall with matter waves.

preprint2005arXiv

Long-distance frequency dissemination with a resolution of 10-17

We use a new technique to disseminate microwave reference signals along ordinary optical fiber. The fractional frequency resolution of a link of 86 km in length is 10-17 for a one day integration time, a resolution higher than the stability of the best microwave or optical clocks. We use the link to compare the microwave reference and a CO2/OsO4 frequency standard that stabilizes a femtosecond laser frequency comb. This demonstrates a resolution of 3.10-14 at 1 s. An upper value of the instability introduced by the femtosecond laser-based synthesizer is estimated as 1.10-14 at 1 s.