Researcher profile

Michal Tarka

Michal Tarka contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - Baseline
2works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2015arXiv

Production and Characterization of 228Th Calibration Sources with Low Neutron Emission for GERDA

The GERDA experiment at the Laboratori Nazionali del Gran Sasso (LNGS) searches for the neutrinoless double beta decay of 76-Ge. In view of the GERDA Phase II data collection, four new 228-Th radioactive sources for the calibration of the germanium detectors enriched in 76-Ge have been produced with a new technique, leading to a reduced neutron flux from ( alpha; n ) reactions. The gamma activities of the sources were determined with a total uncertainty of 4 percent using an ultra-low background HPGe detector operated underground at LNGS. The emitted neutron flux was determined using a low background LiI(Eu) detector and a 3-He counter at LNGS. In both cases, a reduction of about one order of magnitude with respect to commercially available 228-Th sources was obtained. Additionally, a specific leak test with a sensitivity to leaks down to 10 mBq was developed to investigate the tightness of the stainless steel capsules housing the sources after their use in cryogenic environment.

preprint2013arXiv

Monte Carlo Studies and Optimization for the Calibration System of the GERDA Experiment

The GERmanium Detector Array, GERDA, searches for neutrinoless double beta decay in Ge-76 using bare high-purity germanium detectors submerged in liquid argon. For the calibration of these detectors gamma emitting sources have to be lowered from their parking position on top of the cryostat over more than five meters down to the germanium crystals. With the help of Monte Carlo simulations, the relevant parameters of the calibration system were determined. It was found that three Th-228 sources with an activity of 20 kBq each at two different vertical positions will be necessary to reach sufficient statistics in all detectors in less than four hours of calibration time. These sources will contribute to the background of the experiment with a total of (1.07 +/- 0.04(stat) +0.13 -0.19(sys)) 10^{-4} cts/(keV kg yr) when shielded from below with 6 cm of tantalum in the parking position.