Source author record

Alfredo D. Ferella

Alfredo D. Ferella appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2013arXiv

Monte Carlo Studies and Optimization for the Calibration System of the GERDA Experiment

The GERmanium Detector Array, GERDA, searches for neutrinoless double beta decay in Ge-76 using bare high-purity germanium detectors submerged in liquid argon. For the calibration of these detectors gamma emitting sources have to be lowered from their parking position on top of the cryostat over more than five meters down to the germanium crystals. With the help of Monte Carlo simulations, the relevant parameters of the calibration system were determined. It was found that three Th-228 sources with an activity of 20 kBq each at two different vertical positions will be necessary to reach sufficient statistics in all detectors in less than four hours of calibration time. These sources will contribute to the background of the experiment with a total of (1.07 +/- 0.04(stat) +0.13 -0.19(sys)) 10^{-4} cts/(keV kg yr) when shielded from below with 6 cm of tantalum in the parking position.

preprint2011arXiv

Background Measurements in the Gran Sasso Underground Laboratory

The gamma background flux below 3000 keV in the Laboratori Nazionali del Gran Sasso (LNGS), Italy, has been measured using a 3" diameter NaI(Tl) detector at different underground positions: In hall A, hall B, the interferometer tunnel, and inside the Large Volume Detector (LVD). The integrated flux is 0.3--0.4 s$^{-1}$cm$^{-2}$ at the first three locations, and is lower by two orders of magnitude inside LVD. With the help of Monte Carlo simulations for every location, the contribution of the individual primordial isotopes to the background has been determined. Using an 11" diameter NaI(Tl) detector, the background neutron flux in the LNGS interferometer tunnel has been estimated. Within the uncertainties, the result agrees with those from other neutron measurements in the main halls.