Source author record

Max Wilder

Max Wilder appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2016arXiv

Updated Results of a Solid-State Sensor Irradiation Study for ILC Extreme Forward Calorimetry

Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the collider with angles between 5 and 50 milliradians. For the innermost radius of this calorimeter, radiation doses at shower max are expected to reach 100 Mrad per year, primarily due to minimum-ionizing electrons and positrons that arise in the induced electromagnetic showers of e+e- `beamstrahlung' pairs produced in the ILC beam-beam interaction. However, radiation damage to calorimeter sensors may be dominated by hadrons induced by nuclear interactions of shower photons, which are much more likely to contribute to the non-ionizing energy loss that has been observed to damage sensors exposed to hadronic radiation. We report here on the results of SLAC Experiment T-506, for which several different types of silicon diode and gallium-arsenide sensors were exposed to doses of radiation induced by showering electrons of energy 3.5-13.3 GeV. By embedding the sensor under irradiation within a tungsten radiator, the exposure incorporated hadronic species that would potentially contribute to the degradation of a sensor mounted in a precision sampling calorimeter. Depending on sensor technology, efficient charge collection was observed for doses as large as 270 Mrad.

preprint2011arXiv

Generic Microstrip R&D Topics at SCIPP: Longitudinal Charge Division and Length Limitations for Long Strips

We discuss results on the use of charge division to estimate the longitudinal position of charge deposition in silicon microstrip sensors, and on the intrinsic noise limitation of microstrip sensors in the limit of long, narrow strips. We find a resolution of \pm6% of the length of the sensor for a 10cm-long sensor. We also find that network effects significantly reduce sensor readout noise relative to naive expectations that arise from treating the detector resistance and capacitance as single discrete electronic components.