Source author record

Matteo Lucchini

Matteo Lucchini appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

Novel beamline for attosecond transient reflection spectroscopy in a sequential two-foci geometry

We present an innovative beamline for extreme ultraviolet (XUV)-infrared (IR) pump-probe reflection spectroscopy in solids with attosecond temporal resolution. The setup uses an actively stabilized interferometer, where attosecond pulse trains or isolated attosecond pulses are produced by high-order harmonic generation in gases. After collinear recombination, the attosecond XUV pulses and the femtosecond IR pulses are focused twice in sequence by toroidal mirrors, giving two spatially separated interaction regions. In the first region, the combination of a gas target with a time-of-flight spectrometer allows for attosecond photoelectron spectroscopy experiments. In the second focal region, an XUV reflectometer is used for attosecond transient reflection spectroscopy (ATRS) experiments. Since the two measurements can be performed simultaneously, precise pump-probe delay calibration can be achieved, thus opening the possibility for a new class of attosecond experiments on solids. Successful operation of the beamline is demonstrated by the generation and characterization of isolated attosecond pulses, the measurement of the absolute reflectivity of SiO2, and by performing simultaneous photoemission/ATRS in Ge.

preprint2020arXiv

Unravelling the intertwined atomic and bulk nature of localised excitons by attosecond spectroscopy

The electro-optical properties of most semiconductors and insulators of technological interest are dominated by the presence of electron-hole quasiparticles called excitons. The manipulation of these hydrogen-like quasi-particles in dielectrics, has received great interest under the name excitonics that is expected to be of great potential for a variety of applications, including optoelectronics and photonics. A crucial step for such exploitation of excitons in advanced technological applications is a detailed understanding of their dynamical nature. However, the ultrafast processes unfolding on few-femtosecond and attosecond time scales, of primary relevance in view of the desired extension of electronic devices towards the petahertz regime, remain largely unexplored. Here we apply attosecond transient reflection spectroscopy in a sequential two-foci geometry and observe sub-femtosecond dynamics of a core-level exciton in bulk MgF$_2$ single crystals. With our unique setup, we can access absolute phase delays which allow for an unambiguous comparison with theoretical calculations based on the Wannier-Mott model. Our results show that excitons surprisingly exhibit a dual atomic- and solid-like character which manifests itself on different time scales. While the former is responsible for a femtosecond optical Stark effect, the latter dominates the attosecond excitonic response and originates by the interaction with the crystal. Further investigation of the role of exciton localization proves that the bulk character persists also for strongly localised quasi-particles and allows us to envision a new route to control exciton dynamics in the close-to-petahertz regime.

preprint2015arXiv

Time delay anisotropy in photoelectron emission from the isotropic ground state of helium

Time delays of electrons emitted from an isotropic initial state and leaving behind an isotropic ion are assumed to be angle-independent. Using an interferometric method involving XUV attosecond pulse trains and an IR probe field in combination with a detection scheme, which allows for full 3D momentum resolution, we show that measured time delays between electrons liberated from the $1s^2$ spherically symmetric ground state of helium depend on the emission direction of the electrons relative to the linear polarization axis of the ionizing XUV light. Such time-delay anisotropy, for which we measure values as large as 60 attoseconds, is caused by the interplay between final quantum states with different symmetry and arises naturally whenever the photoionization process involves the exchange of more than one photon in the field of the parent-ion. With the support of accurate theoretical models, the angular dependence of the time delay is attributed to small phase differences that are induced in the laser-driven continuum transitions to the final states. Since most measurement techniques tracing attosecond electron dynamics involve the exchange of at least two photons, this is a general, significant, and initially unexpected effect that must be taken into account in all such photoionization measurements.

preprint2014arXiv

Multiphoton transitions for delay-zero calibration in attosecond spectroscopy

The exact delay-zero calibration in an attosecond pump-probe experiment is important for the correct interpretation of experimental data. In attosecond transient absorption spectroscopy the determination of the delay-zero exclusively from the experimental results is not straightforward and may introduce significant errors. Here, we report the observation of quarter-laser-cycle (4ω) oscillations in a transient absorption experiment in helium using an attosecond pulse train overlapped with a precisely synchronized, moderately strong infrared pulse. We demonstrate how to extract and calibrate the delay-zero with the help of the highly nonlinear 4ω signal. A comparison with the solution of the time-dependent Schrödinger equation is used to confirm the accuracy and validity of the approach. Moreover, we study the mechanisms behind the quarter-laser-cycle and the better-known half-laser-cycle oscillations as a function of experimental parameters. This investigation yields an indication of the robustness of our delay-zero calibration approach.