Source author record

Masatoshi Kitajima

Masatoshi Kitajima appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Proton radiation damage tolerance of wide dynamic range SOI pixel detectors

We have been developing the SOI pixel detector ``INTPIX'' for space use and general purpose applications such as the residual stress measurement of a rail and high energy physics experiments. INTPIX is a monolithic pixel detector composed of a high-resistivity Si sensor, a SiO2 insulator, and CMOS pixel circuits utilizing Silicon-On-Insulator (SOI) technology. We have considered the possibility of using INTPIX to observe X-ray polarization in space. When the semiconductor detector is used in space, it is subject to radiation damage resulting from high-energy protons. Therefore, it is necessary to investigate whether INTPIX has high radiation tolerance for use in space. The INTPIX8 was irradiated with 6 MeV protons up to a total dose of 2 krad at HIMAC, National Institute of Quantum Science in Japan, and evaluated the degradation of the performance, such as energy resolution and non-uniformity of gain and readout noise between pixels. After 500 rad irradiation, which is the typical lifetime of an X-ray astronomy satellite, the degradation of energy resolution at 14.4 keV is less than 10%, and the non-uniformity of readout noise and gain between pixels is constant within 0.1%.

preprint2020arXiv

Radiation Damage Effects on Double-SOI Pixel Sensors for X-ray Astronomy

The X-ray SOI pixel sensor onboard the FORCE satellite will be placed in the low earth orbit and will consequently suffer from the radiation effects mainly caused by geomagnetically trapped cosmic-ray protons. Based on previous studies on the effects of radiation on SOI pixel sensors, the positive charges trapped in the oxide layer significantly affect the performance of the sensor. To improve the radiation hardness of the SOI pixel sensors, we introduced a double-SOI (D-SOI) structure containing an additional middle Si layer in the oxide layer. The negative potential applied on the middle Si layer compensates for the radiation effects, due to the trapped positive charges. Although the radiation hardness of the D-SOI pixel sensors for applications in high-energy accelerators has been evaluated, radiation effects for astronomical application in the D-SOI sensors has not been evaluated thus far. To evaluate the radiation effects of the D-SOI sensor, we perform an irradiation experiment using a 6-MeV proton beam with a total dose of ~ 5 krad, corresponding to a few tens of years of in-orbit operation. This experiment indicates an improvement in the radiation hardness of the X- ray D-SOI devices. On using an irradiation of 5 krad on the D-SOI device, the energy resolution in the full-width half maximum for the 5.9-keV X-ray increases by 7 $\pm$ 2%, and the chip output gain decreases by 0.35 $\pm$ 0.09%. The physical mechanism of the gain degradation is also investigated; it is found that the gain degradation is caused by an increase in the parasitic capacitance due to the enlarged buried n-well.