Source author record

Martin Hoeferkamp

Martin Hoeferkamp appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2023arXiv

Investigation of low gain avalanche detectors exposed to proton fluences beyond 10$^{15}$ n$_\mathrm{eq}$cm$^{-2}$

Low gain avalanche detectors (LGADs) deliver excellent timing resolution, which can mitigate mis-assignment of vertices associated with pileup at the High Luminosity LHC and other future hadron colliders. The most highly irradiated LGADs will be subject to $2.5 \times10^{15} \mathrm{n}_\mathrm{eq} \mathrm{cm}^{-2}$ of hadronic fluence during HL-LHC operation; their performance must tolerate this. Hamamatsu Photonics K.K. and Fondazione Bruno Kessler LGADs have been irradiated with 400 and 500 MeV protons respectively in several steps up to $1.5 \times10^{15} \mathrm{n}_\mathrm{eq} \mathrm{cm}^{-2}$. Measurements of the acceptor removal constants of the gain layers, evolution of the timing resolution and charge collection with damage, and inter-channel isolation characteristics, for a variety of design options, are presented here.

preprint2013arXiv

A Method for Real Time Monitoring of Charged Particle Beam Profile and Fluence

Detectors planned for use at the Large Hadron Collider will operate in a radiation field produced by beam collisions. To predict the radiation damage to the components of the detectors, prototype devices are irradiated at test beam facilities that reproduce the radiation conditions expected. The profile of the test beam and the fluence applied per unit time must be known. Techniques such as thin metal foil activation and radiographic image analysis have been used to measure these; however, some of these techniques do not operate in real time, have low sensitivity, or have large uncertainties. We have developed a technique to monitor in real time the beam profile and fluence using an array of $p-i-n$ semiconductor diodes whose forward voltage is linear with fluence over the fluence regime relevant to, for example, tracking in the LHC Upgrade era. We have demonstrated this technique in the 800 MeV proton beam at the LANSCE facility of Los Alamos National Laboratory.

preprint2013arXiv

Effect of Temperature and Charged Particle Fluence on the Resistivity of Polycrystalline CVD Diamond Sensors

The resistivity of polycrystalline chemical vapor deposition diamond sensors is studied in samples exposed to fluences relevant to the environment of the High Luminosity Large Hadron Collider. We measure the leakage current for a range of bias voltages on samples irradiated with 800 MeV protons up to 1.6\times 10^{16} p/cm^2. The proton beam at LANSCE, Los Alamos National Laboratory, was applied to irradiate the samples. The devices' resistivity is extracted for temperatures in the -10^\circC to +20^\circC range.