Researcher profile

Marshall W. Bautz

Marshall W. Bautz contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

Measurement and simulation of charge diffusion in a small-pixel charge-coupled device

Future high-resolution imaging X-ray observatories may require detectors with both fine spatial resolution and high quantum efficiency at relatively high X-ray energies (>5keV). A silicon imaging detector meeting these requirements will have a ratio of detector thickness to pixel size of six or more, roughly twice that of legacy imaging sensors. This implies greater diffusion of X-ray charge packets. We investigate consequences for sensor performance, reporting charge diffusion measurements in a fully-depleted, 50um thick, back-illuminated CCD with 8um pixels. We are able to measure the size distributions of charge packets produced by 5.9 keV and 1.25 keV X-rays in this device. We find that individual charge packets exhibit a gaussian spatial distribution, and determine the frequency distribution of event widths for a range of internal electric field strength levels. We find a standard deviation for the largest charge packets, which occur near the entrance window, of 3.9um. We show that the shape of the event width distribution provides a clear indicator of full depletion and infer the relationship between event width and interaction depth. We compare measured width distributions to simulations. We compare traditional, 'sum-above-threshold' algorithms for event amplitude determination to 2D gaussian fitting of events and find better spectroscopic performance with the former for 5.9 keV events and comparable results at 1.25 keV. The reasons for this difference are discussed. We point out the importance of read noise driven detection thresholds in spectral resolution, and note that the derived read noise requirements for mission concepts such as AXIS and Lynx may be too lax to meet spectral resolution requirements. While we report measurements made with a CCD, we note that they have implications for the performance of high aspect-ratio silicon active pixel sensors as well.

preprint2022arXiv

Mitigating the effects of particle background on the Athena Wide-Field Imager

The Wide Field Imager (WFI) flying on Athena will usher in the next era of studying the hot and energetic Universe. WFI observations of faint, diffuse sources will be limited by uncertainty in the background produced by high-energy particles. These particles produce easily identified "cosmic-ray tracks" along with signals from secondary photons and electrons generated by particle interactions with the instrument. The signal from these secondaries is identical to the X-rays focused by the optics, and cannot be filtered without also eliminating these precious photons. As part of a larger effort to understand the WFI background, we here present results from a study of background-reduction techniques that exploit the spatial correlation between cosmic-ray particle tracks and secondary events. We use Geant4 simulations to generate a realistic particle background, sort this into simulated WFI frames, and process those frames in a similar way to the expected flight and ground software to produce a WFI observation containing only particle background. The technique under study, Self Anti-Coincidence or SAC, then selectively filters regions of the detector around particle tracks, turning the WFI into its own anti-coincidence detector. We show that SAC is effective at improving the systematic uncertainty for observations of faint, diffuse sources, but at the cost of statistical uncertainty due to a reduction in signal. If sufficient pixel pulse-height information is telemetered to the ground for each frame, then this technique can be applied selectively based on the science goals, providing flexibility without affecting the data quality for other science. The results presented here are relevant for any future silicon-based pixelated X-ray imaging detector, and could allow the WFI and similar instruments to probe to truly faint X-ray surface brightness.

preprint2022arXiv

Single electron Sensitive Readout (SiSeRO) X-ray detectors: Technological progress and characterization

Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have developed a readout module based on the drain current of the on-chip transistor to characterize the device. Characterization was performed for a number of prototype sensors with different device architectures, e.g. location of the internal gate, MOSFET polysilicon gate structure, and location of the trough in the internal gate with respect to the source and drain of the MOSFET (the trough is introduced to confine the charge in the internal gate). Using a buried-channel SiSeRO, we have achieved a charge/current conversion gain of >700 pA per electron, an equivalent noise charge (ENC) of around 6 electrons root mean square (RMS), and a full width half maximum (FWHM) of approximately 140 eV at 5.9 keV at a readout speed of 625 Kpixel/s. In this paper, we discuss the SiSeRO working principle, the readout module developed at Stanford, and the characterization test results of the SiSeRO prototypes. We also discuss the potential to implement Repetitive Non-Destructive Readout (RNDR) with these devices and the preliminary results which can in principle yield sub-electron ENC performance. Additional measurements and detailed device simulations will be essential to mature the SiSeRO technology. However, this new device class presents an exciting technology for next generation astronomical X-ray telescopes requiring fast, low-noise, radiation hard megapixel imagers with moderate spectroscopic resolution.

preprint2022arXiv

Towards precision particle background estimation for future X-ray missions: correlated variability between Chandra ACIS and AMS

A science goal of many future X-ray observatories is mapping the cosmic web through deep exposures of faint diffuse sources. Such observations require low background and the best possible knowledge of the remaining unrejected background. The dominant contribution to the background above 1-2 keV is from Galactic Cosmic Ray protons. Their flux and spectrum are modulated by the solar cycle but also by solar activity on shorter timescales. Understanding this variability may prove crucial to reducing background uncertainty for ESA's Athena X-ray Observatory and other missions with large collecting area. We examine of the variability of the particle background as measured by ACIS on the Chandra X-ray Observatory and compare that variability to that measured by the Alpha Magnetic Spectrometer (AMS), a precision particle detector on the ISS. We show that cosmic ray proton variability measured by AMS is well matched to the ACIS background and can be used to estimate proton energies responsible for the background. We discuss how this can inform future missions.

preprint2022arXiv

Understanding the effects of charge diffusion in next-generation soft X-ray imagers

To take advantage of high-resolution optics sensitive to a broad energy range, future X-ray imaging instruments will require thick detectors with small pixels. This pixel aspect ratio affects spectral response in the soft X-ray band, vital for many science goals, as charge produced by the photon interaction near the entrance window diffuses across multiple pixels by the time it is collected, and is potentially lost below the imposed noise threshold. In an effort to understand these subtle but significant effects and inform the design and requirements of future detectors, we present simulations of charge diffusion using a variety of detector characteristics and operational settings, assessing spectral response at a range of X-ray energies. We validate the simulations by comparing the performance to that of real CCD detectors tested in the lab and deployed in space, spanning a range of thickness, pixel size, and other characteristics. The simulations show that while larger pixels, higher bias voltage, and optimal backside passivation improve performance, reducing the readout noise has a dominant effect in all cases. We finally show how high-pixel-aspect-ratio devices present challenges for measuring the backside passivation performance due to the magnitude of other processes that degrade spectral response, and present a method for utilizing the simulations to qualitatively assess this performance. Since compelling science requirements often compete technically with each other (high spatial resolution, soft X-ray response, hard X-ray response), these results can be used to find the proper balance for a future high-spatial-resolution X-ray instrument.

preprint2010arXiv

Late-time detections of the X-ray afterglow of GRB 060729 with Chandra - the latest detections ever of an X-ray afterglow

We report on 5 Chandra observations of the X-ray afterglow of the Gamma-Ray Burst GRB 060729 performed between 2007 March and 2008 May. In all five observations the afterglow is clearly detected. The last Chandra pointing was performed on 2008-May-04, 642 days after the burst - the latest detection of a GRB X-ray afterglow ever. A reanalysis of the Swift XRT light curve together with the three detections by Chandra in 2007 reveals a break at about 1.0 Ms after the burst with a slight steepening of the decay slope from alpha = 1.32 to 1.61. This break coincides with a significant hardening of the X-ray spectrum, consistent with a cooling break in the wind medium scenario, in which the cooling frequency of the afterglow crosses the X-ray band. The last two Chandra observations in 2007 December and 2008 May provide evidence for another break at about one year after the burst. If interpreted as a jet break, this late-time break implies a jet half opening angle of about 14 degrees for a wind medium. Alternatively, this final break may have a spectral origin, in which case no jet break has been observed and the half-opening angle of the jet of GRB 060729 must be larger than about 15 degrees for a wind medium. We compare the X-ray afterglow of GRB 060729 in a wind environment with other bright X-ray afterglows, in particular GRBs 061121 and 080319B, and discuss why the X-ray afterglow of GRB 060729 is such an exceptionally long-lasting event.