Source author record

Mariano Barella

Mariano Barella appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2021arXiv

Challenges on Optical Printing of Colloidal Nanoparticles

While colloidal chemistry provides ways to obtain a great variety of nanoparticles, with different shapes, sizes, material composition, and surface functions, their controlled deposition and combination on arbitrary positions of substrates remains a considerable challenge. Over the last ten years, optical printing arose as a versatile method to achieve this purpose for different kinds of nanoparticles. In this article we review the state of the art of optical printing of single nanoparticles, and discuss its strengths, limitations, and future perspectives, by focusing on four main challenges: printing accuracy, resolution, selectivity, and nanoparticles photostability.

preprint2020arXiv

COTS MOS Dosimetry on the MeMOSat Board, Results After 2.5 Years in Orbit

We present the results after 2.5 years in or-bit of Total Ionizing Dose (TID) measurements done using Metal Oxide Semiconductor (MOS) dosimeters on the MeMOSat board. The MeMOSat board was launched on July 19th 2014 at the BugSat-1 "Tita" microsatellite developed by Satellogic to stay at LEO. We used as dosimeters p-channel Commercial Off The Shelf (COTS) MOS transistors with gate oxides of 250~nm. Before launch, a subset of transistors with similar drain current to voltage (I-V)curves where selected from a group of 100 devices. The temperature dependence of the (I-V) curves was studied to find the minimum temperature coefficient biasing point. Then, a calibration subgroup of sensors was irradiated using a $^{60}$Co gamma source to study their response to TID, showing responsivities of $\sim$75~mV/krad when the sensors are irradiated without gate bias. Also, the post irradiation response of the sensors was monitored, in order to include a correction for low dose rate irradiations, yielding 30~mV/krad. A biasing and reading circuit was developed in order to allow the reading of up to 4 sensors.The threshold voltage was monitored during different periods of the mission. After 2.5 years in orbit,the threshold voltage of the sensor mounted on the MeMOSat Board had a V$_\mathrm{T}$ shift of approximately 35~mV corresponds to a dose of 1.2~krads.