Researcher profile

Marc Schumann

Marc Schumann contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
14works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

14 published item(s)

preprint2022arXiv

GeMSE: a Low-Background Facility for Gamma-Spectrometry at Moderate Rock Overburden

The GeMSE (Germanium Material and meteorite Screening Experiment) facility operates a low-background HPGe crystal in an underground laboratory with a moderate rock overburden of 620$\,$m.w.e. in Switzerland. It has been optimized for continuous remote operation. A multi-layer passive shielding, a muon veto, and a boil-off nitrogen purge line inside the measurement cavity minimize the instrument's background rate, which decreased by 33% to (164$\pm$2)$\,$counts/day (100-2700$\,$keV) after five years of underground operation. This agrees with the prediction based on the expected decay of short-lived isotopes. A fit to the known background components, modeled via a precise simulation of the detector, shows that the GeMSE background is now muon-dominated. We also present updates towards a more accurate detection efficiency calculation for the screened samples: the thickness of the crystal's outer dead-layer is precisely determined and the efficiency can now be easily calculated for any sample geometry. The advantage of this feature is showcased via the determination of the $^{40}$K content in the screening of a complex-shaped object: a banana.

preprint2022arXiv

Prospects of charge signal analyses in liquid xenon TPCs with proportional scintillation in the liquid phase

As liquid xenon TPCs increase in target mass while pursuing the direct detection of WIMP dark matter, the technical challenges arising due to their size call for new solutions and open the discussion on alternative detector concepts. Proportional scintillation in liquid xenon allows for a single-phase design evading all problems related to the liquid-gas interface and the precise gas gap required in a dual-phase TPC. Aside from a different scintillation mechanism, the successful detection- and analysis scheme of state-of-the-art experiments is maintained in this approach. We study the impact on charge signal analysis in a single-phase detector of DARWIN dimensions, where the fast timing of the proportional scintillation signal allows for the precise identification of the single electrons in the ionisation signal. Such a discrete electron-counting approach leads to a better signal resolution for low energies when compared to the classical dual-phase continuous method. The absence of the liquid-gas interface further benefits the S2-only energy resolution significantly. This reduces the uncertainties from the scintillation and signal-detection process to a level significantly below the irreducible fluctuation in the primary ionisation. Exploiting the precise electron time information further allows for a powerful single vs.~multiple site interaction discrimination with 93% rejection efficiency and 98% signal acceptance. This outperforms the design goal of the DARWIN observatory by a reduction factor of 4.2 in non-rejected multiple site neutron events.

preprint2021arXiv

Direct Detection of Dark Matter -- APPEC Committee Report

This Report provides an extensive review of the experimental programme of direct detection searches of particle dark matter. It focuses mostly on European efforts, both current and planned, but does it within a broader context of a worldwide activity in the field. It aims at identifying the virtues, opportunities and challenges associated with the different experimental approaches and search techniques. It presents scientific and technological synergies, both existing and emerging, with some other areas of particle physics, notably collider and neutrino programmes, and beyond. It addresses the issue of infrastructure in light of the growing needs and challenges of the different experimental searches. Finally, the Report makes a number of recommendations from the perspective of a long-term future of the field. They are introduced, along with some justification, in the opening Overview and Recommendations section and are next summarised at the end of the Report. Overall, we recommend that the direct search for dark matter particle interactions with a detector target should be given top priority in astroparticle physics, and in all particle physics, and beyond, as a positive measurement will provide the most unambiguous confirmation of the particle nature of dark matter in the Universe.

preprint2020arXiv

VUV Transmission of PTFE for Xenon-based Particle Detectors

Liquid xenon (LXe) based detectors for rare event searches in particle and astroparticle physics are optimized for high xenon scintillation light collection and low background rate from detector materials. Polytetrafluoroethylene (PTFE, Teflon) is commonly used to encapsulate the active LXe volume due to its high reflectance for VUV LXe scintillation light with peak emission at 178 nm. Reflectance, transmission and number of background signals arising from PTFE depend on the thickness of the PTFE detector walls. In this work, we present VUV transmission measurements for PTFE of various thicknesses often considered in the design phase of LXe detectors. PTFE samples are measured in an apparatus previously used for reflectance measurements in LXe using collimated light at a wavelength of 178 nm. Measurements in vacuum as well as gaseous xenon are described by the Kubelka and Munk model, as well as by Beer-Lambert's law for samples of $\geq 0.7\,\mathrm{mm}$ thickness, yielding a transmission coefficient of $λ_\text{BL} = (0.89 \pm 0.05)\,\mathrm{mm}$. The PTFE wall thickness of the XENONnT dark matter experiment was optimized by these measurements and selected as $\geq 3\,\mathrm{mm}$.

preprint2016arXiv

A versatile and light-weight slow control system for small-scale applications

We present an open source slow control system for small and medium scale projects. Thanks to its modular and flexible design, where the various instruments are read and controlled by independent plugins, Doberman (Detector OBsERving and Monitoring ApplicatioN) can be quickly adapted for many applications, also making use of existing code or proprietary components. The system uses a SQL database to store the data from the instruments and provides an online application to display and browse through the data. It allows the modification of device settings while the program is running and features a protocol to handle exceptions, including the automated distribution of alarm messages. We present two case studies from astroparticle physics, on which Doberman is successfully deployed: a low-background screening facility installed in a remote underground laboratory and a detector R&D platform using cryogenic liquid xenon.

preprint2015arXiv

Cosmogenic activation of xenon and copper

Rare event search experiments using liquid xenon as target and detection medium require ultra-low background levels to fully exploit their physics potential. Cosmic ray induced activation of the detector components and, even more importantly, of the xenon itself during production, transportation and storage at the Earth's surface, might result in the production of radioactive isotopes with long half-lives, with a possible impact on the expected background. We present the first dedicated study on the cosmogenic activation of xenon after 345 days of exposure to cosmic rays at the Jungfraujoch research station at 3470m above sea level, complemented by a study of copper which has been activated simultaneously. We have directly observed the production of 7Be, 101Rh, 125Sb, 126I and 127Xe in xenon, out of which only 125Sb could potentially lead to background for a multi-ton scale dark matter search. The production rates for five out of eight studied radioactive isotopes in copper are in agreement with the only existing dedicated activation measurement, while we observe lower rates for the remaining ones. The specific saturation activities for both samples are also compared to predictions obtained with commonly used software packages, where we observe some underpredictions, especially for xenon activation.

preprint2015arXiv

Dark Matter 2014

This article gives an overview on the status of experimental searches for dark matter at the end of 2014. The main focus is on direct searches for weakly interacting massive particles (WIMPs) using underground-based low-background detectors, especially on the new results published in 2014. WIMPs are excellent dark matter candidates, predicted by many theories beyond the standard model of particle physics, and are expected to interact with the target nuclei either via spin-independent (scalar) or spin-dependent (axial-vector) couplings. Non-WIMP dark matter candidates, especially axions and axion-like particles are also briefly discussed.

preprint2015arXiv

Dark matter sensitivity of multi-ton liquid xenon detectors

We study the sensitivity of multi ton-scale time projection chambers using a liquid xenon target, e.g., the proposed DARWIN instrument, to spin-independent and spin-dependent WIMP-nucleon scattering interactions. Taking into account realistic backgrounds from the detector itself as well as from neutrinos, we examine the impact of exposure, energy threshold, background rejection efficiency and energy resolution on the dark matter sensitivity. With an exposure of 200 t x y and assuming detector parameters which have been already demonstrated experimentally, spin-independent cross sections as low as $2.5 \times 10^{-49}$ cm$^2$ can be probed for WIMP masses around 40 GeV/$c^2$. Additional improvements in terms of background rejection and exposure will further increase the sensitivity, while the ultimate WIMP science reach will be limited by neutrinos scattering coherently off the xenon nuclei.

preprint2014arXiv

Dual-Phase Liquid Xenon Detectors for Dark Matter Searches

Dual-phase time projection chambers (TPCs) filled with the liquid noble gas xenon (LXe) are currently the most sensitive detectors searching for interactions of WIMP dark matter in a laboratory-based experiment. This is achieved by combining a large, monolithic dark matter target of a very low background with the capability to localize the interaction vertex in three dimensions, allowing for target fiducialization and multiple-scatter rejection. The background in dual-phase LXe TPCs is further reduced by the simultaneous measurement of the scintillation and ionization signal from a particle interaction, which is used to distinguish signal from background signatures. This article reviews the principle of dual-phase LXe TPCs, and provides an overview about running as well as future experimental efforts.

preprint2013arXiv

Dark Matter 2013

This article reviews the status of the exciting and fastly evolving field of dark matter research as of summer 2013, when it was discussed at ICRC 2013 in Rio de Janeiro. It focuses on the three main avenues to detect WIMP dark matter: direct detection, indirect detection and collider searches. The article is based on the dark matter rapporteur talk summarizing the presentations given at the conference, filling some gaps for completeness.

preprint2013arXiv

Performance of the Hamamatsu R11410 Photomultiplier Tube in cryogenic Xenon Environments

The Hamamatsu R11410 photomultiplier, a tube of 3" diameter and with a very low intrinsic radioactivity, is an interesting light sensor candidate for future experiments using liquid xenon (LXe) as target for direct dark matter searches. We have performed several experiments with the R11410 with the goal of testing its performance in environments similar to a dark matter detector setup. In particular, we examined its long-term behavior and stability in LXe and its response in various electric field configurations.

preprint2013arXiv

Response of liquid xenon to Compton electrons down to 1.5 keV

The response of liquid xenon to low-energy electronic recoils is relevant in the search for dark-matter candidates which interact predominantly with atomic electrons in the medium, such as axions or axion-like particles, as opposed to weakly interacting massive particles which are predicted to scatter with atomic nuclei. Recently, liquid-xenon scintillation light has been observed from electronic recoils down to 2.1 keV, but without applied electric fields that are used in most xenon dark matter searches. Applied electric fields can reduce the scintillation yield by hindering the electron-ion recombination process that produces most of the scintillation photons. We present new results of liquid xenon's scintillation emission in response to electronic recoils as low as 1.5 keV, with and without an applied electric field. At zero field, a reduced scintillation output per unit deposited energy is observed below 10 keV, dropping to nearly 40% of its value at higher energies. With an applied electric field of 450 V/cm, we observe a reduction of the scintillation output to about 75% relative to the value at zero field. We see no significant energy dependence of this value between 1.5 keV and 7.8 keV. With these results, we estimate the electronic-recoil energy thresholds of ZEPLIN-III, XENON10, XENON100, and XMASS to be 2.8 keV, 2.5 keV, 2.3 keV, and 1.1 keV, respectively, validating their excellent sensitivity to low-energy electronic recoils.

preprint2011arXiv

Background Measurements in the Gran Sasso Underground Laboratory

The gamma background flux below 3000 keV in the Laboratori Nazionali del Gran Sasso (LNGS), Italy, has been measured using a 3" diameter NaI(Tl) detector at different underground positions: In hall A, hall B, the interferometer tunnel, and inside the Large Volume Detector (LVD). The integrated flux is 0.3--0.4 s$^{-1}$cm$^{-2}$ at the first three locations, and is lower by two orders of magnitude inside LVD. With the help of Monte Carlo simulations for every location, the contribution of the individual primordial isotopes to the background has been determined. Using an 11" diameter NaI(Tl) detector, the background neutron flux in the LNGS interferometer tunnel has been estimated. Within the uncertainties, the result agrees with those from other neutron measurements in the main halls.