Researcher profile

Majid Pournezam Esfahani

Majid Pournezam Esfahani contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 11 - UnverifiedVerification L1Unclaimed author
1works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2021arXiv

Dosimetric characterization of a new 192Ir pulse dose rate brachytherapy source with the Monte Carlo simulation and thermoluminescent dosimeter

In this study, recommendations of the AAPM TG- 43 (U1) report have been followed to characterize the new 192Ir pulse dose rate source, provided by the Applied Radiation Research School, Nuclear Science and Technology Research Institute in Iran. Dose rate constant, radial dose function, geometry factors, and anisotropy function were calculated according to the relevant American Association of Physicists in Medicine AAPM and TG43 (U1) reports. In this study, 192Ir source was characterized using Monte Carlo simulation in water phantom, and in addition, experimental measurements were carried out using thermoluminescent dosimeters (TLD-100) in plexiglass (PMMA) phantoms. The dose-rate constant for the 192Ir PDR was found to be equal to 1.131 cGyh-1U-1 and 1.173 cGyh-1U-1 with TLD measurement and Monte Carlo simulation, respectively. Also in this study, the geometry function, radial dose functions g(r), and the anisotropy function have been calculated at distances from 0.1 to 16 cm. The dose-rate constant of these calculations has been compared with measured values for an actual 192Ir seed. The results of dosimetry parameters, presented in tabulated and graphical formats, exhibited good agreement to those reported from other commercially available PDR 192Ir sources. The results obtained in this study are in close agreement with the characteristics of the commercially available 192Ir sources. The results obtained in this study can be treated as an initial assessment of this source to be employed in the conventional treatment planning systems subsequent to complementary investigations.