Researcher profile

M. P. Ledbetter

M. P. Ledbetter contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
11works
0followers
8topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2012arXiv

Polarized nuclear target based on parahydrogen induced polarization

We discuss a novel concept of a polarized nuclear target for accelerator fixed-target scattering experiments, which is based on parahydrogen induced polarization (PHIP). One may be able to reach a 33% free-proton polarization in the ethane molecule. The potential advantages of such a target include operation at zero magnetic field, fast ($\sim$100 Hz) polarization reversal, and operation with large intensity of an electron beam.

preprint2012arXiv

Small-sized Dichroic Atomic Vapor Laser Lock (DAVLL)

Two, lightweight diode laser frequency stabilization systems designed for experiments in the field are described. A significant reduction in size and weight in both models supports the further miniaturization of measurement devices in the field. Similar to a previous design, magnetic-field lines are contained within a magnetic shield enclosing permanent magnets and a Rb cell, so that these DAVLL systems may be used for magnetically sensitive instruments. The Mini-DAVLL system (49 mm long) uses a vapor cell (20 mm long), and does not require cell heaters. An even smaller Micro-DAVLL system (9mm long) uses a micro-fabricated cell (3 mm square), and requires heaters. These new systems show no degradation in performance with regard to previous designs, while considerably reducing dimensions.

preprint2011arXiv

All-optical atomic magnetometers based on nonlinear magneto-optical rotation with amplitude modulated light

We demonstrate a magnetometric technique based on nonlinear magneto-optical rotation using amplitude modulated light. The magnetometers can be operated in either open-loop (typical nonlinear magneto-optical rotation with amplitude-modulated light) or closed-loop (self-oscillating) modes. The latter mode is particularly well suited for conditions where the magnetic field is changing by large amounts over a relatively short timescale.

preprint2010arXiv

Broadband magnetometry by infrared-absorption detection of nitrogen-vacancy ensembles in diamond

We demonstrate magnetometry by detection of the spin state of high-density nitrogen-vacancy ensembles in diamond using optical absorption at 1042 nm. With this technique, measurement contrast, and collection efficiency can approach unity, leading to an increase in magnetic sensitivity compared to the more common method of collecting red fluorescence. Working at 75 K with a sensor with effective volume $50 \times 50 \times 300$ microns^3, we project photon shot-noise limited sensitivity of 5 pT in one second of acquisition and bandwidth from dc to a few megahertz. Operation in a gradiometer configuration yields a noise floor of 7 nTrms at ~110 Hz in one second of acquisition.

preprint2010arXiv

Temperature dependence of the nitrogen-vacancy magnetic resonance in diamond

The temperature dependence of the magnetic resonance spectra of nitrogen-vacancy (NV-) ensembles in the range of 280-330 K was studied. Four samples prepared under different conditions were studied with NV- concentrations ranging from 10 ppb to 15 ppm. For all of these samples, the axial zero-field splitting (ZFS) parameter, D, was found to vary significantly with temperature, T, as dD/dT = -74.2(7) kHz/K. The transverse ZFS parameter, E, was non-zero (between 4 and 11 MHz) in all samples, and exhibited a temperature dependence of dE/(EdT) = -1.4(3) x 10^(-4) K^(-1). The results might be accounted for by considering local thermal expansion. The observation of the temperature dependence of the ZFS parameters presents a significant challenge for room-temperature diamond magnetometers and may ultimately limit their bandwidth and sensitivity.

preprint2009arXiv

Cancellation of nonlinear Zeeman shifts with light shifts

Nonlinear Zeeman (NLZ) shifts arising from magnetic-field mixing of the two hyperfine ground-states in alkali atoms lead to splitting of magnetic-resonance lines. This is a major source of sensitivity degradation and the so-called "heading errors" of alkali-vapor atomic magnetometers operating in the geophysical field range (B approx. 0.2-0.7 G). Here, it is shown theoretically and experimentally that NLZ shifts can be effectively canceled by light shifts caused by a laser field of appropriate intensity, polarization and frequency, a technique that can be readily applied in practical situations.

preprint2009arXiv

High nitrogen-vacancy density diamonds for magnetometry applications

Nitrogen-vacancy (NV) centers in millimeter-scale diamond samples were produced by irradiation and subsequent annealing under varied conditions. The optical and spin relaxation properties of these samples were characterized using confocal microscopy, visible and infrared absorption, and optically detected magnetic resonance. The sample with the highest NV- concentration, approximately 16 ppm = 2.8 x 10^{18} cm^{-3}, was prepared with no observable traces of neutrally-charged vacancy defects. The effective transverse spin relaxation time for this sample was T2* = 118(48) ns, predominately limited by residual paramagnetic nitrogen which was determined to have a concentration of 52(7) ppm. Under ideal conditions, the shot-noise limited sensitivity is projected to be ~150 fT/\sqrt{Hz} for a 100 micron-scale magnetometer based on this sample. Other samples with NV- concentrations from .007 to 12 ppm and effective relaxation times ranging from 27 to 291 ns were prepared and characterized.

preprint2007arXiv

Production and detection of atomic hexadecapole at Earth's magnetic field

Anisotropy of atomic states is characterized by population differences and coherences between Zeeman sublevels. It can be efficiently created and probed via resonant interactions with light, the technique which is at the heart of modern atomic clocks and magnetometers. Recently, nonlinear magneto-optical techniques have been developed for selective production and detection of higher polarization moments, hexadecapole and hexacontatetrapole, in the ground states of the alkali atoms. Extension of these techniques into the range of geomagnetic fields is important for practical applications. This is because hexadecapole polarization corresponding to the $ΔM=4$ Zeeman coherence, with maximum possible $ΔM$ for electronic angular momentum $J=1/2$ and nuclear spin $I=3/2$, is insensitive to the nonlinear Zeeman effect (NLZ). This is of particular interest because NLZ normally leads to resonance splitting and systematic errors in atomic magnetometers. However, optical signals due to the hexadecapole moment decline sharply as a function of magnetic field. We report a novel method that allows selective creation of a macroscopic long-lived ground-state hexadecapole polarization. The immunity of the hexadecapole signal to NLZ is demonstrated with F=2 $^{87}$Rb atoms at Earth's field.

preprint2007arXiv

Spin-exchange relaxation free magnetometry with Cs vapor

We describe a Cs atomic magnetometer operating in the spin-exchange relaxation-free (SERF) regime. With a vapor cell temperature of $103^\circ\rm{C}$ we achieve intrinsic magnetic resonance widths $ΔB=17 {\rm μG}$ corresponding to an electron spin-relaxation rate of $300 {\rm s^{-1}}$ when the spin-exchange rate is $Γ_{SE}=14000 {\rm s^{-1}}$. We also observe an interesting narrowing effect due to diffusion. Signal-to-noise measurements yield a sensitivity of about $400\thinspace{\rm pG/\sqrt{Hz}}$. Based on photon shot noise, we project a sensitivity of $40 {\rm pG/\sqrt{Hz}}$. A theoretical optimization of the magnetometer indicates sensitivities on the order of $2 {\rm pG/\sqrt{Hz}}$ should be achievable in a $1 {\rm cm^3}$ volume. Because Cs has a higher saturated vapor pressure than other alkali metals, SERF magnetometers using Cs atoms are particularly attractive in applications requiring lower temperatures.

preprint2006arXiv

Detection of radio frequency magnetic fields using nonlinear magneto-optical rotation

We describe a room-temperature alkali-metal atomic magnetometer for detection of small, high frequency magnetic fields. The magnetometer operates by detecting optical rotation due to the precession of an aligned ground state in the presence of a small oscillating magnetic field. The resonance frequency of the magnetometer can be adjusted to any desired value by tuning the bias magnetic field. We demonstrate a sensitivity of $100\thinspace{\rm pG/\sqrt{Hz}\thinspace(RMS)}$ in a 3.5 cm diameter, paraffin coated cell. Based on detection at the photon shot-noise limit, we project a sensitivity of $20\thinspace{\rm pG/\sqrt{Hz}\thinspace(RMS)}$.

preprint2006arXiv

Nonlinear magneto-optical rotation with frequency-modulated light in the geophysical field range

Recent work investigating resonant nonlinear magneto-optical rotation (NMOR) related to long-lived ($τ\ts{rel} \sim 1 {\rm s}$) ground-state atomic coherences has demonstrated potential magnetometric sensitivities exceeding $10^{-11} {\rm G/\sqrt{Hz}}$ for small ($\lesssim 1 {\rm μG}$) magnetic fields. In the present work, NMOR using frequency-modulated light (FM NMOR) is studied in the regime where the longitudinal magnetic field is in the geophysical range ($\sim 500 {\rm mG}$), of particular interest for many applications. In this regime a splitting of the FM NMOR resonance due to the nonlinear Zeeman effect is observed. At sufficiently high light intensities, there is also a splitting of the FM NMOR resonances due to ac Stark shifts induced by the optical field, as well as evidence of alignment-to-orientation conversion type processes. The consequences of these effects for FM-NMOR-based atomic magnetometry in the geophysical field range are considered.