Source author record

M. Kiehn

M. Kiehn appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

Electrical Characterization of 180 nm ATLASPix2 HV-CMOS Monolithic Prototypes for the High-Luminosity LHC

We report on the experimental study made on a successive prototype of High-Voltage CMOS (HV-CMOS) ATLASPix2 sensor for the tracking detector application, developed with 180 nm feature size. These sensors are to qualify mainly the peripheral data processing blocks (e.g. Command Decoder, Trigger Buffer, etc.). It is a smaller version of 24 X 36 pixelated sensor in comparison to the earlier generation of ATLASPix1 fabricated in both ams AG, Austria, and TSI Semiconductors, USA. While ams produced ATLASPix2 showed breakdown voltage 50 V in nonirradiated condition as it was seen on its predecessors ATLASpix1, TSI produced prototypes reported breakdown voltage greater than 100 V. The chosen wafer of MCz 20 Ohm.cm P-type substrate resistivity can deplete a few tenths of um, where the process-driven surface damage can have a greater impact on device operating conditions before and after irradiation. In an aim to understand device intrinsic performance at the irradiated case, a dedicated neutron irradiation campaign has been made at JSI for different fluences. Characterizations have been performed at different temperatures after irradiation to analyze the leakage current and breakdown voltage before and after irradiation. TSI prototypes showed a breakdown voltage decrease 90 V due to impact ionization and enhanced effective doping concentration. Results demonstrated for the neutron-irradiated devices up to the fluence of 2 X 10^15 neq/cm2 can still safely be operated at a voltage high enough to allow for high efficiency. Accelerated Annealing steps also made on selective irradiated ATLASPix2 samples, equivalent to more than two years of room-temperature annealing (at 20 degC), and they showed the reassuring expected breakdown voltage increase and damage constant rate alpha^* (geometry dependent) decrease, driven by the beneficial annealing.

preprint2020arXiv

MuPix and ATLASPix -- Architectures and Results

High Voltage Monolithic Active Pixel Sensors (HV-MAPS) are based on a commercial High Voltage CMOS process and collect charge by drift inside a reversely biased diode. HV-MAPS represent a promising technology for future pixel tracking detectors. Two recent developments are presented. The MuPix has a continuous readout and is being developed for the Mu3e experiment whereas the ATLASPix is being developed for LHC applications with a triggered readout. Both variants have a fully monolithic design including state machines, clock circuitries and serial drivers. Several prototypes and design variants were characterised in the lab and in testbeam campaigns to measure efficiencies, noise, time resolution and radiation tolerance. Results from recent MuPix and ATLASPix prototypes are presented and prospects for future improvements are discussed.

preprint2019arXiv

EUDAQ $-$ A Data Acquisition Software Framework for Common Beam Telescopes

EUDAQ is a generic data acquisition software developed for use in conjunction with common beam telescopes at charged particle beam lines. Providing high-precision reference tracks for performance studies of new sensors, beam telescopes are essential for the research and development towards future detectors for high-energy physics. As beam time is a highly limited resource, EUDAQ has been designed with reliability and ease-of-use in mind. It enables flexible integration of different independent devices under test via their specific data acquisition systems into a top-level framework. EUDAQ controls all components globally, handles the data flow centrally and synchronises and records the data streams. Over the past decade, EUDAQ has been deployed as part of a wide range of successful test beam campaigns and detector development applications.

preprint2013arXiv

Research Proposal for an Experiment to Search for the Decay μ -> eee

We propose an experiment (Mu3e) to search for the lepton flavour violating decay mu+ -> e+e-e+. We aim for an ultimate sensitivity of one in 10^16 mu-decays, four orders of magnitude better than previous searches. This sensitivity is made possible by exploiting modern silicon pixel detectors providing high spatial resolution and hodoscopes using scintillating fibres and tiles providing precise timing information at high particle rates.