Researcher profile

M. Hughes

M. Hughes contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
14works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

14 published item(s)

preprint2026arXiv

Enhanced sensitivity to trace $^{238}$U impurity of sapphire via coincidence neutron activation analysis

Sapphire has mechanical and electrical properties that are advantageous for the construction of internal components of radiation detectors such as time projection chambers and bolometers. However, it has proved difficult to assess its $\rm ^{232}Th$ and $\rm ^{238}U$ content down to the picogram per gram level. This work reports an experimental verification of a computational study that demonstrates $γγ$ coincidence counting, coupled with neutron activation analysis (NAA), can reach ppt sensitivities. Combining results from $γγ$ coincidence counting with those of earlier single-$γ$ counting based NAA shows that a sample of Saint Gobain sapphire has $\rm ^{232}Th$ and $\rm ^{238}U$ concentrations of $<0.26$ ppt and $<2.3$ ppt, respectively; the best constraints on the radiopurity of sapphire.

preprint2022arXiv

A COHERENT constraint on leptophobic dark matter using CsI data

We use data from the COHERENT CsI[Na] scintillation detector to constrain sub-GeV leptophobic dark matter models. This detector was built to observe low-energy nuclear recoils from coherent elastic neutrino-nucleus scattering. These capabilities enable searches for dark matter particles produced at the Spallation Neutron Source mediated by a vector portal particle with masses between 2 and 400 MeV/c$^2$. No evidence for dark matter is observed and a limit on the mediator coupling to quarks is placed. This constraint improves upon previous results by two orders of magnitude. This newly explored parameter space probes the region where the dark matter relic abundance is explained by leptophobic dark matter when the mediator mass is roughly twice the dark matter mass. COHERENT sets the best constraint on leptophobic dark matter at these masses.

preprint2022arXiv

Measurement of the Coherent Elastic Neutrino-Nucleus Scattering Cross Section on CsI by COHERENT

We measured the cross section of coherent elastic neutrino-nucleus scattering (\cevns{}) using a CsI[Na] scintillating crystal in a high flux of neutrinos produced at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. New data collected before detector decommissioning has more than doubled the dataset since the first observation of \cevns{}, achieved with this detector. Systematic uncertainties have also been reduced with an updated quenching model, allowing for improved precision. With these analysis improvements, the COHERENT collaboration determined the cross section to be $(165^{+30}_{-25})\times10^{-40}$~cm$^2$, consistent with the standard model, giving the most precise measurement of \cevns{} yet. The timing structure of the neutrino beam has been exploited to compare the \cevns{} cross section from scattering of different neutrino flavors. This result places leading constraints on neutrino non-standard interactions while testing lepton flavor universality and measures the weak mixing angle as $\sin^2θ_{W}=0.220^{+0.028}_{-0.026}$ at $Q^2\approx(50\text{ MeV})^2$

preprint2022arXiv

Monitoring the SNS basement neutron background with the MARS detector

We present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for the purpose of monitoring and characterizing the beam-related neutron (BRN) background for the COHERENT collaboration. MARS was positioned next to the COH-CsI coherent elastic neutrino-nucleus scattering detector in the SNS basement corridor. This is the basement location of closest proximity to the SNS target and thus, of highest neutrino flux, but it is also well shielded from the BRN flux by infill concrete and gravel. These data show the detector registered roughly one BRN per day. Using MARS&#39; measured detection efficiency, the incoming BRN flux is estimated to be $1.20~\pm~0.56~\text{neutrons}/\text{m}^2/\text{MWh}$ for neutron energies above $\sim3.5$ MeV and up to a few tens of MeV. We compare our results with previous BRN measurements in the SNS basement corridor reported by other neutron detectors.

preprint2022arXiv

Simulating the neutrino flux from the Spallation Neutron Source for the COHERENT experiment

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is a pulsed source of neutrons and, as a byproduct of this operation, an intense source of pulsed neutrinos via stopped-pion decay. The COHERENT collaboration uses this source to investigate coherent elastic neutrino-nucleus scattering and other physics with a suite of detectors. This work includes a description of our Geant4 simulation of neutrino production at the SNS and the flux calculation which informs the COHERENT studies. We estimate the uncertainty of this calculation at about 10% based on validation against available low-energy pion production data.

preprint2022arXiv

The COHERENT Experimental Program

The COHERENT experiment located in Neutrino Alley at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL), has made the world&#39;s first two measurements of coherent elastic neutrino-nucleus scattering (CEvNS), on CsI and argon, using neutrinos produced at the SNS. The COHERENT collaboration continues to pursue CEvNS measurements on various targets as well as additional studies of inelastic neutrino-nucleus interactions, searches for accelerator-produced dark matter (DM) and physics beyond the Standard Model, using the uniquely high-quality and high-intensity neutrino source available at the SNS. This white paper describes primarily COHERENT&#39;s ongoing and near-future program at the SNS First Target Station (FTS). Opportunities enabled by the SNS Second Target Station (STS) for the study of neutrino physics and development of novel detector technologies are elaborated in a separate white paper.

preprint2021arXiv

First Measurement of Coherent Elastic Neutrino-Nucleus Scattering on Argon

We report the first measurement of coherent elastic neutrino-nucleus scattering (\cevns) on argon using a liquid argon detector at the Oak Ridge National Laboratory Spallation Neutron Source. Two independent analyses prefer \cevns over the background-only null hypothesis with greater than $3σ$ significance. The measured cross section, averaged over the incident neutrino flux, is (2.2 $\pm$ 0.7) $\times$10$^{-39}$ cm$^2$ -- consistent with the standard model prediction. The neutron-number dependence of this result, together with that from our previous measurement on CsI, confirms the existence of the \cevns process and provides improved constraints on non-standard neutrino interactions.

preprint2021arXiv

The EXO-200 detector, part II: Auxiliary Systems

The EXO-200 experiment searched for neutrinoless double-beta decay of $^{136}$Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. This paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.

preprint2020arXiv

COHERENT Collaboration data release from the first detection of coherent elastic neutrino-nucleus scattering on argon

Release of COHERENT collaboration data from the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on argon. This release corresponds with the results of &#34;Analysis A&#34; published in Akimov et al., arXiv:2003.10630 [nucl-ex]. Data is shared in a binned, text-based format representing both &#34;signal&#34; and &#34;backgrounds&#34; along with associated uncertainties such that the included data can be used to perform independent analyses. This document describes the contents of the data release as well as guidance on the use of the data. Included example code in C++ (ROOT) and Python show one possible use of the included data.

preprint2020arXiv

Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment

Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by $γ$ interactions from $^{228}$Th (2615~keV), $^{226}$Ra (1764~keV) and $^{60}$Co (1332~keV and 1173~keV) calibration sources, over a range of electric fields. The $W$-value that defines the recombination-independent energy scale is measured to be $11.5~\pm~0.5$~(syst.)~$\pm~0.1$~(stat.) eV. These data are also used to measure the recombination fluctuations in the number of electrons and photons produced by the calibration sources at the MeV-scale, which deviate from extrapolations of lower-energy data. Additionally, a semi-empirical model for the energy resolution of the detector is developed, which is used to constrain the recombination efficiency, i.e., the fraction of recombined electrons that result in the emission of a detectable photon. Detailed measurements of the absolute charge and light yields for MeV-scale electron recoils are important for predicting the performance of future neutrinoless double beta decay detectors.

preprint2020arXiv

Measurement of the Spectral Shape of the beta-decay of 137Xe to the Ground State of 137Cs in EXO-200 and Comparison with Theory

We report on a comparison between the theoretically predicted and experimentally measured spectra of the first-forbidden non-unique $β$-decay transition $^{137}\textrm{Xe}(7/2^-)\to\,^{137}\textrm{Cs}(7/2^+)$. The experimental data were acquired by the EXO-200 experiment during a deployment of an AmBe neutron source. The ultra-low background environment of EXO-200, together with dedicated source deployment and analysis procedures, allowed for collection of a pure sample of the decays, with an estimated signal-to-background ratio of more than 99-to-1 in the energy range from 1075 to 4175 keV. In addition to providing a rare and accurate measurement of the first-forbidden non-unique $β$-decay shape, this work constitutes a novel test of the calculated electron spectral shapes in the context of the reactor antineutrino anomaly and spectral bump.

preprint2019arXiv

Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode

Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semi-transparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measured drift velocities and corresponding temperature coefficients respectively are $1.97 \pm 0.04$ mm/$μ$s and $(-0.69\pm0.05)$\%/K for liquid xenon, and $1.42 \pm 0.03$ mm/$μ$s and $(+0.11\pm0.01)$\%/K for gaseous xenon at 1.5 bar. In addition, we measure longitudinal diffusion coefficients of $25.7 \pm 4.6$ cm$^2$/s and $149 \pm 23$ cm$^2$/s, for liquid and gas, respectively. The quantum efficiency of the gold photocathode is studied at the photon energy of 4.73 eV in liquid and gaseous xenon, and vacuum. These charge transport properties and the behavior of photocathodes in a xenon environment are important in designing and calibrating future large scale noble liquid detectors.

preprint2019arXiv

Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths

Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angular dependence of the specular reflectance in a vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 nm to 280 nm. Refractive index and extinction coefficient of the thin silicon-dioxide film deposited on the surface of the FBK SiPMs are derived from reflectance data of a FBK silicon wafer with the same deposited oxide film as SiPMs. The diffuse reflectance of SiPMs is also measured at 193 nm. We use the VUV spectral dependence of the optical constants to predict the reflectance of the FBK silicon wafer and FBK SiPMs in liquid xenon.

preprint2019arXiv

Reflectivity and PDE of VUV4 Hamamatsu SiPMs in Liquid Xenon

Understanding reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE. Little information is currently available about reflectivity and PDE in liquid noble gases, because such measurements are difficult to conduct in a cryogenic environment and at short enough wavelengths. Here we report a measurement of specular reflectivity and relative PDE of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 micrometer micro-cells conducted with xenon scintillation light (~175 nm) in liquid xenon. The specular reflectivity at 15 deg. incidence of three samples of VUV4 SiPMs is found to be 30.4+/-1.4%, 28.6+/-1.3%, and 28.0+/-1.3%, respectively. The PDE at normal incidence differs by +/-8% (standard deviation) among the three devices. The angular dependence of the reflectivity and PDE was also measured for one of the SiPMs. Both the reflectivity and PDE decrease as the angle of incidence increases. This is the first measurement of an angular dependence of PDE and reflectivity of a SiPM in liquid xenon.