Source author record

Ludovic Bellon

Ludovic Bellon appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

18works
10topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

18 published item(s)

preprint2024arXiv

Reliability and operation cost of underdamped memories during cyclic erasures

The reliability of fast repeated erasures is studied experimentally and theoretically in a 1-bit underdamped memory. The bit is encoded by the position of a micro-mechanical oscillator whose motion is confined in a double well potential. To contain the energetic cost of fast erasures, we use a resonator with high quality factor $Q$: the erasure work $W$ is close to Landauer's bound, even at high speed. The drawback is the rise of the system's temperature $T$ due to a weak coupling to the environment. Repeated erasures without letting the memory thermalize between operations result in a continuous warming, potentially leading to a thermal noise overcoming the barrier between the potential wells. In such case, the reset operation can fail to reach the targeted logical state. The reliability is characterized by the success rate $R^s_i$ after $i$ successive operations. $W$, $T$ and $R^s_i$ are studied experimentally as a function of the erasure speed. Above a velocity threshold, $T$ soars while $R^s_i$ collapses: the reliability of too fast erasures is low. These experimental results are fully justified by two complementary models. We demonstrate that $Q\simeq 10$ is optimal to contain energetic costs and maintain high reliability standards for repeated erasures at any speed.

preprint2022arXiv

Dynamics of information erasure and extension of Landauer's bound to fast processes

Using a double-well potential as a physical memory, we study with experiments and numerical simulations the energy exchanges during erasure processes, and model quantitatively the cost of fast operation. Within the stochastic thermodynamics framework we find the origins of the overhead to Landauer's Bound required for fast operations: in the overdamped regime this term mainly comes from the dissipation, while in the underdamped regime it stems from the heating of the memory. Indeed, the system is thermalized with its environment at all time during quasi-static protocols, but for fast ones, the inefficient heat transfer to the thermostat is delayed with respect to the work influx, resulting in a transient temperature rise. The warming, quantitatively described by a comprehensive statistical physics description of the erasure process, is noticeable on both the kinetic and potential energy: they no longer comply with equipartition. The mean work and heat to erase the information therefore increase accordingly. They are both bounded by an effective Landauer's limit $k_B T_{eff} \ln{2}$, where $T_{eff}$ is a weighted average of the actual temperature of the memory during the process.

preprint2022arXiv

Harmonic calibration of quadrature phase interferometry

The two output signals of quadrature phase interferometers allow to benefit both from the high sensitivity of interferometry (working inside a fringe) and from an extended input range (counting fringes). Their calibration to reach a linear output is traditionally performed using Heydemann's correction, which involves fitting one output versus the other by an ellipse. Here we present two alternative methods based on the linear response of the measurement to a sinusoidal input in time, which enables a direct calibration with an excellent linearity. A ten fold improvement with respect to the usual technique is demonstrated on an optical interferometer measuring the deflection of scanning force microscopy cantilevers.

preprint2022arXiv

Virtual double-well potential for an underdamped oscillator created by a feedback loop

Virtual potentials are a very elegant, precise and flexible tool to manipulate small systems and explore fundamental questions in stochastic thermodynamics. In particular double-well potentials have applications in information processing, such as the demonstration of Landauer's principle. Nevertheless, virtual double-well potentials had never been implemented in underdamped systems. In this article, we detail how to face the experimental challenge of creating a feedback loop for an underdamped system (exploring its potential energy landscape much faster than its over-damped counterpart), in order to build a tunable virtual double-well potential. To properly describe the system behavior in the feedback trap, we express the switching time in the double-well for all barrier heights, combining for the first time Kramer's description, valid at high barriers, with an adjusted model for lower ones. We show that a small hysteresis or delay of the feedback loop in the switches between the two wells results in a modified velocity distribution, interpreted as a cooling of the kinetic temperature of the system. We successfully address all issues to create experimentally a virtual potential that is statistically indistinguishable from a physical one, with a tunable barrier height and energy step between the two wells.

preprint2020arXiv

Extended equipartition in a mechanical system subject to a heat flow: the case of localised dissipation

Statistical physics in equilibrium grants us one of its most powerful tools: the equipartition principle. It states that the degrees of freedom of a mechanical system act as a thermometer: temperature is equal to the mean variance of their oscillations divided by their stiffness. However, when a non-equilibrium state is considered, this principle is no longer valid. In our experiment, we study the fluctuations of a micro-cantilever subject to a strong heat flow, which creates a highly non-uniform local temperature. We measure independently the temperature profile of the object and the temperature yielded from the mechanical thermometers, thus testing the validity of the equipartition principle out of equilibrium. We demonstrate how the fluctuations of the most energetic degrees of freedom are equivalent to the temperature at the base of the cantilever, even when the average temperature is several hundreds of degrees higher. We then present a model based on the localised mechanical dissipation in the system to account for our results, which correspond to mechanical losses localised at the clamping position.

preprint2019arXiv

Extended Nyquist formula for a resistance subject to a heat flow

The Nyquist formula quantifies the thermal noise driven fluctuations of voltage across a resistance in equilibrium. We deal here with the case of a resistance driven out of equilibrium by putting it in contact with two thermostats at different temperatures. We reach a non-equilibrium steady state where a heat flux is flowing through the resistance. Our measurements demonstrate anyway that a simple extension of the Nyquist formula to the non uniform temperature field describes with an excellent precision the thermal noise. For a metallic ohmic material, the fluctuations are actually equivalent to those of a resistance in equilibrium with a single thermostat at the mean temperature between the hot and cold sources.

preprint2015arXiv

High Resolution Viscosity Measurement by Thermal Noise Detection

An interferometric method is implemented in order to accurately assess the thermal fluctuations of a micro-cantilever sensor in liquid environments. The power spectrum density (PSD) of thermal fluctuations together with Sader's model of the cantilever allow for the indirect measurement of the liquid viscosity with good accuracy. The good quality of the deflection signal and the characteristic low noise of the instrument allow for the detection and corrections of drawbacks due to both the cantilever shape irregularities and the uncertainties on the position of the laser spot at the fluctuating end of the cantilever. Variation of viscosity below 0.03 mPa$\cdot$s was detected with the alternative to achieve measurements with a volume as low as 50 $μ$L.

preprint2015arXiv

Resonance frequency shift of strongly heated micro-cantilevers

In optical detection setups to measure the deflection of micro-cantilevers, part of the sensing light is absorbed, heating the mechanical probe. We present experimental evidences of a frequency shift of the resonant modes of a cantilever when the light power of the optical measurement set-up is increased. This frequency shift is a signature of the temperature rise, and presents a dependence on the mode number. An analytical model is derived to take into account the temperature profile along the cantilever, it shows that the frequency shifts are given by an average of the profile weighted by the local curvature for each resonant mode. We apply this framework to measurements in vacuum and demonstrate that huge temperatures can be reached with moderate light intensities: a thousand {\textdegree}C with little more than 10 mW. We finally present some insight into the physical phenomena when the cantilever is in air instead of vacuum.

preprint2015arXiv

Simultaneous and accurate measurement of the dielectric constant at many frequencies spanning a wide range

We present an innovative technique which allows the simultaneous measurement of the dielectric constant of a material at many frequencies, spanning a four orders of magnitude range chosen between 10 --2 Hz and 10 4 Hz. The sensitivity and accuracy are comparable to those obtained using standard single frequency techniques. The technique is based on three new and simple features: a) the precise real time correction of the amplication of a current amplier; b) the specic shape of the excitation signal and its frequency spectrum; and c) the precise synchronization between the generation of the excitation signal and the acquisition of the dielectric response signal. This technique is useful in the case of relatively fast dynamical measurements when the knowledge of the time evolution of the dielectric constant is needed.

preprint2014arXiv

Adhesion energy of single wall carbon nanotube loops on various substrates

The physics of adhesion of one-dimensional nano structures such as nanotubes, nano wires, and biopolymers on different material substrates is of great interest for the study of biological adhesion and the development of nano electronics and nano mechanics. In this paper, we present force spectroscopy experiments of a single wall carbon nanotube loop using our home-made interferometric atomic force microscope. Characteristic force plateaux during the peeling process allows us to access to quantitative values of the adhesion energy per unit length on various substrates: graphite, mica, platinum, gold and silicon. By combining a time-frequency analysis of the deflexion of the cantilever, we access to the dynamic stiffness of the contact, providing more information on the nanotube configurations and its intrinsic mechanical properties.

preprint2014arXiv

Measurements of mechanical thermal noise and energy dissipation in optical dielectric coatings

In recent years an increasing number of devices and experiments are shown to be limited by mechanical thermal noise. In particular sub-Hertz laser frequency stabilization and gravitational wave detectors, that are able to measure fluctuations of 1E-18 m/rtHz or less, are being limited by thermal noise in the dielectric coatings deposited on mirrors. In this paper we present a new measurement of thermal noise in low absorption dielectric coatings deposited on micro-cantilevers and we compare it with the results obtained from the mechanical loss measurements. The coating thermal noise is measured on the widest range of frequencies with the highest signal to noise ratio ever achieved. In addition we present a novel technique to deduce the coating mechanical losses from the measurement of the mechanical quality factor which does not rely on the knowledge of the coating and substrate Young moduli. The dielectric coatings are deposited by ion beam sputtering. The results presented here give a frequency independent loss angle of (4.70 $\pm$ 0.2)x1E-4 with a Young's modulus of 118 GPa for annealed tantala from 10 Hz to 20 kHz. For as-deposited silica, a weak frequency dependence (~ f^{-0.025}) is observed in this frequency range, with a Young's modulus of 70 GPa and an internal damping of (6.0 $\pm$ 0.3)x1E-4 at 16 kHz, but this value decreases by one order of magnitude after annealing and the frequency dependence disappears.

preprint2013arXiv

Functionalized AFM probes for force spectroscopy: eigenmodes shape and stiffness calibration through thermal noise measurements

The functionalization of an Atomic Force Microscope (AFM) cantilever with a colloidal bead is a widely used technique when the geometry between the probe and the sample must be controlled, particularly in force spectroscopy. But some questions remain: how does a bead glued at the end of a cantilever influence its mechanical response ? And more important for quantitative measurements, can we still determine the stiffness of the AFM probe with traditional techniques? In this article, the influence of a colloidal mass loading on the eigenmodes shape and resonant frequency is investigated by measuring the thermal noise on rectangular AFM microcantilevers with and without a bead attached at their extremities. The experiments are performed with a home-made ultra-sensitive AFM, based on differential interferometry. The focused beam from the interferometer probes the cantilever at different positions and the spatial shapes of the modes are determined up to the fifth resonance, without external excitation. The results clearly demonstrate that the first eigenmode almost doesn't change by mass loading. However the oscillation behavior of higher resonances present a marked difference: with a particle glued at its extremity, the nodes of the mode are displaced towards the free end of the cantilever. These results are compared to an analytical model taking into account the mass and the inertial moment of the load in an Euler-Bernoulli framework, where the normalization of the eigenmodes is explicitly worked out in order to allow a quantitative prediction of the thermal noise amplitude of each mode. A good agreement between the experimental results and the analytical model is demonstrated, allowing a clean calibration of the probe stiffness.

preprint2013arXiv

Microrheology measurements with a hanging-fiber AFM probe

A method to measure the viscosity of liquids at microscales is presented. It uses a thin glass fiber fixed on the tip of the cantilever of an extremely low noise Atomic Force Microscope (AFM), which accurately measures the cantilever {deflection}. When the fiber is dipped into the liquid the dissipation of the cantilever-fiber system increases. This dissipation, linked to the liquid viscosity, is computed from the power spectral density of the thermal fluctuations of the cantilever {deflection}. The {high sensitivity of the AFM} allows us to show the existence and to develop a model of the coupling between the dynamics of the fiber and that of the cantilever. This model {accurately} fits the experimental data. The advantages and draw-backs of the method are discussed

preprint2013arXiv

Quadrature phase interferometer for high resolution force spectroscopy

In this article, we present a deflection measurement setup for Atomic Force Microscopy (AFM). It is based on a quadrature phase differential interferometer: we measure the optical path difference between a laser beam reflecting above the cantilever tip and a reference beam reflecting on the static base of the sensor. A design with very low environmental susceptibility and another allowing calibrated measurements on a wide spectral range are described. Both enable a very high resolution (down to $\SI{2.5E-15}{m/\sqrt{Hz}}$), illustrated by thermal noise measurements on AFM cantilevers. They present an excellent long-term stability, and a constant sensitivity independent of the optical phase of the interferometer. A quick review shows that our precision is equaling or out-performing the best results reported in the literature, but for a much larger deflection range, up to a few $\SI{}{\micro m}$.

preprint2011arXiv

Dissipation of micro-cantilevers as a function of air pressure and metallic coating

In this letter, we characterize the internal dissipation of coated micro-cantilevers through their mechanical thermal noise. Using a home-made interferometric setup, we achieve a resolution down to 1E-14m/rtHz in the measurement of their deflection. With the use of the fluctuation dissipation theorem and of the Kramers-Kronig relations, we rebuilt the full mechanical response function from the measured noise spectrum, and investigate frequency dependent dissipation as a function of the air pressure and of the nature of the metallic coatings. Using different thicknesses of gold coatings, we discuss the source of the internal viscoelastic damping.

preprint2010arXiv

Carbon nanotubes adhesion and nanomechanical behavior from peeling force spectroscopy

Applications based on Single Walled Carbon Nanotube (SWNT) are good example of the great need to continuously develop metrology methods in the field of nanotechnology. Contact and interface properties are key parameters that determine the efficiency of SWNT functionalized nanomaterials and nanodevices. In this work we have taken advantage of a good control of the SWNT growth processes at an atomic force microscope (AFM) tip apex and the use of a low noise (1E-13 m/rtHz) AFM to investigate the mechanical behavior of a SWNT touching a surface. By simultaneously recording static and dynamic properties of SWNT, we show that the contact corresponds to a peeling geometry, and extract quantities such as adhesion energy per unit length, curvature and bending rigidity of the nanotube. A complete picture of the local shape of the SWNT and its mechanical behavior is provided.

preprint2009arXiv

Steady state fluctuation relations for systems driven by an external random force

We experimentally study the fluctuations of the work done by an external Gaussian random force on two different stochastic systems coupled to a thermal bath: a colloidal particle in an optical trap and an atomic force microscopy cantilever. We determine the corresponding probability density functions for different random forcing amplitudes ranging from a small fraction to several times the amplitude of the thermal noise. In both systems for sufficiently weak forcing amplitudes the work fluctuations satisfy the usual steady state fluctuation theorem. As the forcing amplitude drives the system far from equilibrium, deviations of the fluctuation theorem increase monotonically. The deviations can be recasted to a single master curve which only depends on the kind of stochastic external force.

preprint2007arXiv

Coupling between aging and convective motion in a colloidal glass of Laponite

We study thermal convection in a colloidal glass of Laponite in formation. Low concentration preparation are submitted to destabilizing vertical temperature gradient, and present a gradual transition from a turbulent convective state to a steady conductive state as their viscosity increases. The time spent under convection is found to depend strongly on sample concentration, decreasing exponentially with mass fraction of colloidal particles. Moreover, at fixed concentration, it also depends slightly on the pattern selected by the Rayleigh Bénard instability: more rolls maintain the convection state longer. This behavior can be interpreted with recent theoretical approaches of soft glassy material rheology.