Source author record

Lucile Rutkowski

Lucile Rutkowski appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

Optical frequency comb Fourier transform cavity ring-down spectroscopy

We demonstrate broadband and sensitive cavity ring-down spectroscopy using a near infrared frequency comb and a time-resolved Fourier transform spectrometer. The cavity decays are measured simultaneously and spectrally sorted, leading to purely exponential decays for each spectral element. The absorption spectra of atmospheric water and carbon dioxide are retrieved and demonstrate the high frequency resolution and absorption precision of the technique. The experimental apparatus, the measurement concept and the data treatment are described. The technique benefits from the advantages of cavity ring-down spectroscopy, i.e. the retrieved absorption does not depend on the cavity parameters, opening up for high accuracy absorption spectroscopy entirely calibration-free.

preprint2020arXiv

A new instrument for kinetics and branching ratio studies of gas phase collisional processes at very low temperatures

A new instrument dedicated to the kinetic study of low-temperature gas phase neutral-neutral reactions, including clustering processes, is presented. It combines a supersonic flow reactor with Vacuum Ultra-Violet (VUV) synchrotron photoionization time of flight mass spectrometry. A photoion-photoelectron coincidence detection scheme has been adopted to optimize the particle counting efficiency. The characteristics of the instrument are detailed along with its capabilities illustrated through a few results obtained at low temperatures (< 100 K) including a {photoionization spectrum} of n-butane, the detection of formic acid dimer formation as well as the observation of diacetylene molecules formed by the reaction between the C$_2$H radical and C$_2$H$_2$.

preprint2016arXiv

Continuous Vernier filtering of an optical frequency comb for broadband cavity-enhanced molecular spectroscopy

We have recently introduced the Vernier-based Direct Frequency Comb Cavity-Enhanced Spectroscopy technique and we present the corresponding formalism for quantitative broadband spectroscopy. We achieve high sensitivity and broadband performance by acquiring spectra covering more than 2000 cm$^{-1}$ around 12600 cm$^{-1}$ (800 nm), resolving the 3$ν$+$δ$ band of water vapor and the entire A-band of oxygen in ambient air. 31 300 independent spectral elements are acquired at the second time scale with an absorption baseline noise of 2$\times$10$^{-8}$ cm$^{-1}$ providing a merit figure of 1,1.10$^{-10}$ cm$^{-1}$/$\sqrt{Hz}$ with a cavity finesse of 3000 and a cavity round-trip length around 3,3 m. This state-of-the-art performance is reached through a continuous Vernier filtering of a Titanium:Saphire frequency comb with the cavity grid of resonances, obtained when the cavity free spectral range and the laser repetition rate are slightly mismatched. Here, we discuss the effect of the Vernier filtering on the measured absorbtion lineshape and we derive the formalism needed to fit molecular spectra.

preprint2016arXiv

Optical frequency comb spectroscopy at 3-5.4 μm with a doubly resonant optical parametric oscillator

We present a versatile mid-infrared frequency comb spectroscopy system based on a doubly resonant optical parametric oscillator tunable in the 3-5.4 μm range and two detection methods, a Fourier transform spectrometer (FTS) and a Vernier spectrometer. Using the FTS with a multipass cell we measure high-precision broadband absorption spectra of CH$_4$ and NO at ~3.3 μm and ~5.2 μm, respectively, and of atmospheric species (CH$_4$, CO, CO$_2$ and H$_2$O) in air in the signal and idler wavelength range. The figure of merit of the system is on the order of 10$^{-8}$ cm$^{-1}$ Hz$^{-1/2}$ per spectral element, and multiline fitting yields minimum detectable concentrations of 10-20 ppb Hz$^{-1/2}$ for CH$_4$, NO and CO. For the first time in the mid-infrared, we perform continuous-filtering Vernier spectroscopy using a low finesse enhancement cavity, a grating and a single detector, and measure the absorption spectrum of CH$_4$ and H$_2$O in ambient air at ~3.3 μm.

preprint2015arXiv

Surpassing the Path-Limited Resolution of a Fourier Transform Spectrometer with Frequency Combs

Fourier transform spectroscopy based on incoherent light sources is a well-established tool in research fields from molecular spectroscopy and atmospheric monitoring to material science and biophysics. It provides broadband molecular spectra and information about the molecular structure and composition of absorptive media. However, the spectral resolution is fundamentally limited by the maximum delay range (Δ$_{max}$) of the interferometer, so acquisition of high-resolution spectra implies long measurement times and large instrument size. We overcome this limit by combining the Fourier transform spectrometer with an optical frequency comb and measuring the intensities of individual comb lines by precisely matching the Δ$_{max}$ to the comb line spacing. This allows measurements of absorption lines narrower than the nominal (optical path-limited) resolution without ringing effects from the instrumental lineshape and reduces the acquisition time and interferometer length by orders of magnitude.