Source author record

Lucas Burigo

Lucas Burigo appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2019arXiv

Impact of new ICRU90 key data on stopping-power ratios and beam quality correction factors for carbon ion beams

The recent update of dosimetric key data by the `International Commission on Radiation Units and Measurements' impacts the computation of beam quality correction factors $k_Q$ via several changes, e.g. for the mean excitation energies, $I$, which enters the stopping power computation for water and air, the computation procedure itself, the average energy expended in the production of an ion pair in air, $W/e$, as well as chamber perturbation factors for Cobalt-60. An accurate assessment of water-to-air stopping-power ratio, $s_{\rm w,air}$, in reference conditions with new recommendation is necessary to update the dosimetry protocols for carbon ion beams. The new ICRU90 key data were considered for computation of $s_{\rm w,air}$ for carbon ion beams using Monte Carlo transport simulations for a number of reference conditions, namely monoenergetic carbon ion beams with range in water from 3 to 30\,cm and Spread-Out Bragg peaks (SOBPs) of different widths and depths in water. New recommendations for $s_{\rm w,air}$ are presented, namely 1.1247 for the reference condition of 1\,g\,cm$^{-2}$ depth for monoenergetic carbon ion beams and 1.1274 at the center of physically-optimized SOBPs. The recommendation of a constant value (1.126) represents the stopping-power ratio within a 0.3\,\% variation of $s_{\rm w,air}$ for the different reference conditions. The impact of these new $s_{\rm w,air}$ values and the updated key data on the $k_Q$ for carbon ion beams was evaluated in a second step. The changes agree very well with experimental data for the case of cylindrical ionization chambers, but larger discrepancies are observed for plate-parallel ionization chambers.

preprint2014arXiv

Comparative study of RBE and cell survival fractions for $^{1}$H, $^{4}$He, $^{12}$C and $^{16}$O beams using Geant4 and Microdosimetric Kinetic model

Beams of $^{4}$He and $^{16}$O nuclei are considered for ion-beam cancer therapy as alternative options to protons and $^{12}$C nuclei. Spread-out Bragg peak (SOBP) distributions of physical dose and relative biological effectiveness for 10% survival are calculated by means of our Geant4-based Monte Carlo model for Heavy Ion Therapy (MCHIT) and the modified microdosimetric kinetic model. The depth distributions of cell survival fractions are calculated for $^{1}$H, $^{4}$He, $^{12}$C and $^{16}$O for tissues with normal (HSG cells), low and high radiosensitivity. In each case the cell survival fractions were compared separately for the target volume, behind and in front of it. In the case of normal radiosensitivity $^{4}$He and $^{12}$C better spare tissues in the entrance channel compared to protons and $^{16}$O. The cell survival fractions calculated, respectively, for the entrance channel and target volume are similar for $^{4}$He and $^{12}$C. When it is important to spare healthy tissues located after the distal edge of the SOBP plateau, $^{4}$He can be recommended due to reduced nuclear fragmentation of these projectiles. No definite advantages of $^{16}$O with respect to $^{12}$C were found, with the except of an enhanced impact of these heavier projectiles on radioresistant tumors.

preprint2013arXiv

Microdosimetry of radiation field from therapeutic C-12 beam in water: a study with Geant4 toolkit

We model the responses of Tissue-Equivalent Proportional Counters (TEPC) to radiation fields of therapeutic C-12 beams in a water phantom and to quasi-monoenergetic neutrons in a PMMA phantom. Simulations are performed with the Monte Carlo model for Heavy Ion Therapy (MCHIT) based on the Geant4 toolkit. The shapes of the calculated lineal energy spectra agree well with measurements in both cases. The influence of fragmentation reactions on the TEPC response to a narrow pencil-like beam with its width smaller than the TEPC diameter is investigated by Monte Carlo modeling. It is found that total lineal energy spectra are not very sensitive to the choice of the nuclear fragmentation model used. The calculated frequency-mean lineal energy y_f differs from the data on the axis of a therapeutic beam by less than 10% and by 10-20% at other TEPC positions. The validation of MCHIT with neutron beams gives us confidence in estimating the contributions to lineal energy spectra due to secondary neutrons produced in water by C-12 nuclei. As found, the neutron contribution at 10 cm distance from the beam axis amounts to ~ 50% close the entrance to the phantom and decreases to ~ 25% at the depth of the Bragg peak and beyond it. The presented results can help in evaluating biological out-of-field doses in carbon-ion therapy.

preprint2013arXiv

Microdosimetry spectra and RBE of H-1, He-4, Li-7 and C-12 nuclei in water studied with Geant4

A Geant4-based Monte Carlo model for Heavy-Ion Therapy (MCHIT) is used to study radiation fields of H-1, He-4, Li-7 and C-12 beams with similar ranges (~160-180 mm) in water. Microdosimetry spectra are simulated for wall-less and walled Tissue Equivalent Proportional Counters (TEPCs) placed outside or inside a phantom, as in experiments performed, respectively, at NIRS, Japan and GSI, Germany. The impact of fragmentation reactions on microdosimetry spectra is investigated for He-4, Li-7 and C-12, and contributions from nuclear fragments of different charge are evaluated for various TEPC positions in the phantom. The microdosimetry spectra measured on the beam axis are well described by MCHIT, in particular, in the vicinity of the Bragg peak. However, the simulated spectra for the walled TEPC far from the beam axis are underestimated. Relative Biological Effectiveness (RBE) of the considered beams is estimated using a modified microdosimetric-kinetic model. Calculations show a similar rise of the RBE up to 2.2-2.9 close to the Bragg peak for helium, lithium and carbon beams compared to the modest values of 1-1.2 at the plateau region. Our results suggest that helium and lithium beams are also promising options for cancer therapy.