Source author record

Li-Ming Liu

Li-Ming Liu appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

High-sensitivity millimeter imaging of molecular outflows in nine nearby high-mass star-forming regions

We present a study of molecular outflows using six molecular lines (including 12CO/13CO/C18O/HCO+(J = 1-0) and SiO/CS(J = 2-1)) toward nine nearby high-mass star-forming regions with accurate known distances. This work is based on the high-sensitivity observations obtained with the 14-m millimeter telescope of Purple Mountain Observatory Delingha (PMODLH) observatory. The detection rate of outflows (including 12CO, 13CO, HCO+, and CS) is 100\%. However, the emission of SiO was not detected for all sources. The full line widths ($ΔV$) at 3$σ$ above the baseline of these molecular lines have the relationship $ΔV_{\rm ^{12}CO} > ΔV_{\rm HCO^{+}} > ΔV_{\rm CS} \approx ΔV_{\rm ^{13}CO} > ΔV_{\rm ^{18}CO}$. 12CO and HCO+ can be used to trace relatively high-velocity outflows, while 13CO and CS can be employed to trace relatively low-velocity outflows. The dynamical timescales of the 13CO and CS outflows are longer than those of the 12CO and HCO+ outflows. The mechanical luminosities, masses, mass-loss rates and forces of all outflows (including 12CO, 13CO, HCO+, and CS) are correlated with the bolometric luminosities of their central IRAS sources.

preprint2020arXiv

Principal Component Analysis Based on T$\ell_1$-norm Maximization

Classical principal component analysis (PCA) may suffer from the sensitivity to outliers and noise. Therefore PCA based on $\ell_1$-norm and $\ell_p$-norm ($0 < p < 1$) have been studied. Among them, the ones based on $\ell_p$-norm seem to be most interesting from the robustness point of view. However, their numerical performance is not satisfactory. Note that, although T$\ell_1$-norm is similar to $\ell_p$-norm ($0 < p < 1$) in some sense, it has the stronger suppression effect to outliers and better continuity. So PCA based on T$\ell_1$-norm is proposed in this paper. Our numerical experiments have shown that its performance is superior than PCA-$\ell_p$ and $\ell_p$SPCA as well as PCA, PCA-$\ell_1$ obviously.