Researcher profile

Laurent Navarro

Laurent Navarro contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2014arXiv

Efficiency and comfort of knee braces: A parametric study based on computational modelling

Knee orthotic devices are widely proposed by physicians and medical practitioners for preventive or therapeutic objectives in relation with their effects, usually known as to stabilize joint or restrict ranges of motion. This study focuses on the understanding of force transfer mechanisms from the brace to the joint thanks to a Finite Element Model. A Design Of Experiments approach was used to characterize the stiffness and comfort of various braces in order to identify their mechanically influent characteristics. Results show conflicting behavior: influent parameters such as the brace size or textile stiffness improve performance in detriment of comfort. Thanks to this computational tool, novel brace designs can be tested and evaluated for an optimal mechanical efficiency of the devices and a better compliance of the patient to the treatment.

preprint2013arXiv

Using a Monte-Carlo-based approach to evaluate the uncertainty on fringe projection technique

A complete uncertainty analysis on a given fringe projection set-up has been performed using Monte-Carlo approach. In particular the calibration procedure is taken into account. Two applications are given: at a macroscopic scale, phase noise is predominant whilst at microscopic scale, both phase noise and calibration errors are important. Finally, uncertainty found at macroscopic scale is close to some experimental tests (~100 μm).

preprint2010arXiv

Influence of proteins from physiological solutions on the electrochemical behaviour of the Ti-6Al-4V alloy: reproducibility and time-frequency dependence. ---- Influence de la teneur en protéines de solutions physiologiques sur le comportement électrochimique du Ti-6Al-4V : reproductibilité et représentation temps-fréquence

The electrochemical behaviour of the biomedical and metallic alloys, especially in the orthopaedic implants fields, raises many questions. This study is dedicated for studying the Ti-6Al-4V alloy, by electrochemical impedance spectroscopy, EIS, in various physiological media,: Ringer solution, phosphate buffered solution (PBS), PBS solution and albumin, PBS solution with calf serum and PBS solution with calf serum and an antioxidant (sodium azide). Moreover, the desionised water was considered as the reference solution. The tests reproducibility was investigated. The time-frequency-Module graphs highlighted that the desionised water is the most protective for the Ti-6Al-4V alloy. This biomedical alloy is the less protected in the solution constituted by PBS and albumin. The time-frequency graph allows pointing out the graphic signatures of adsorption for organic and inorganic species (differences between the modules means in studied solution and the modules mean in the reference solution). --- Le comportement électrochimique des alliages métalliques biomédicaux, notamment dans le domaine des implants orthopédiques, pose encore de nombreuses questions. Ce travail propose d'étudier l'alliage de titane Ti-6Al-4V, par spectroscopie d'impédance électrochimique, SIE, dans différents milieux physiologiques : solution de Ringer, solution à base d'un tampon phosphate (PBS), solution PBS avec de l'albumine, solution PBS avec du sérum bovin et une solution PBS avec du sérum bovin et un antioxydant (azoture de sodium). De plus, une solution d'eau ultra-pure servira de référence. La reproductibilité des tests a été étudiée. Les représentations temps-fréquence des modules ont mis en évidence que l'eau désionisée est la solution qui présente le caractère le plus protecteur pour le Ti-6Al-4V. Cet alliage de titane est le moins protégé dans la solution de PBS contenant de l'albumine. Cette représentation permet de mettre en évidence des signatures graphiques d'adsorption des espèces inorganiques et organiques (différences entre les moyennes des modules dans les solutions étudiées et la moyenne des modules dans la solution de référence).