Source author record

Klaus Kirch

Klaus Kirch appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

15works
10topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

15 published item(s)

preprint2022arXiv

Characterization of a continuous muon source for the Muon-Induced X-ray Emission (MIXE) Technique

The toolbox for material characterization has never been richer than today. Great progress with all kinds of particles and interaction methods provide access to nearly all properties of an object under study. However, a tomographic analysis of the subsurface region remains still a challenge today. In this regard, the Muon-Induced X-ray Emission (MIXE) technique has seen rebirth fueled by the availability of high intensity muon beams. We report here a study conducted at the Paul Scherrer Institute (PSI). It demonstrates that the absence of any beam time-structure leads to low pile-up events and a high signal-to-noise ratio (SNR) with less than one hour acquisition time per sample or data point. This performance creates the perspective to open this technique to a wider audience for the routine investigation of non-destructive and depth-sensitive elemental compositions, for example in rare and precious samples. Using a hetero-structured sample of known elements and thicknesses, we successfully detected the characteristic muonic X-rays, emitted during the capture of a negative muon by an atom, and the gamma-rays resulting from the nuclear capture of the muon, characterizing the capabilities of MIXE at PSI. This sample emphasizes the quality of a continuous beam, and the exceptional SNR at high rates. Such sensitivity will enable totally new statistically intense aspects in the field of MIXE, e.g. elemental 3D-tomography and chemical analysis. Therefore, we are currently advancing our proof-of-concept experiments with the goal of creating a full fledged permanently operated user station to make MIXE available to the wider scientific community as well as industry.

preprint2022arXiv

muEDM: Towards a search for the muon electric dipole moment at PSI using the frozen-spin technique

The search for a permanent electric dipole moment (EDM) of the muon is an excellent probe for physics beyond the Standard Model of particle physics. We propose the first dedicated muon EDM search employing the frozen-spin technique at the Paul Scherrer Institute (PSI), Switzerland, with a sensitivity of $6 \times 10^{-23}~e\!\cdot\!\mathrm{cm}$, improving the current best limit set by the E821 experiment at Brookhaven National Laboratory by more than three orders of magnitude. In preparation for a high precision experiment to measure the muon EDM, several R&D studies have been performed at PSI: the characterisation of a possible beamline to host the experiment for the muon beam injection study and the measurement of the multiple Coulomb scattering of positrons in potential detector materials at low momenta for the positron tracking scheme development. This paper discusses experimental concepts and the current status of the muEDM experiment at PSI.

preprint2020arXiv

Ultracold Neutrons

Ultracold neutrons (UCN) are free neutrons that can be stored in experimental setups for several minutes. Some of the most important properties of the neutron, such as its tiny permanent electric dipole moment and its beta decay lifetime, are best measured with UCN. Also searches for well motivated but yet unknown, hypothetical additional interactions are being pursued with UCN. Such measurements in the field of low-energy, precision physics may have far reaching implications from particle physics to cosmology. Most experiments are statistics limited and need high-intensity UCN sources. The UCN source at PSI is at the forefront of the field and home to the international nEDM collaboration and its world-leading search for the neutron electric dipole moment. This article aims at giving an overview of the fascinating research using ultracold neutrons emphasizing on activities at PSI including various physics side-analyses which were pioneered by the nEDM collaboration.

preprint2016arXiv

Antimatter gravity with muonium

The gravitational acceleration of antimatter, $\bar{g}$, has never been directly measured and could bear importantly on our understanding of gravity, the possible existence of a fifth force, and the nature and early history of the universe. Three avenues appear feasible for such a measurement: antihydrogen, positronium, and muonium. The muonium measurement requires a novel monoenergetic, low-velocity, horizontal muonium beam directed at an atom interferometer. The precision three-grating interferometer can be produced in silicon nitride or ultrananocrystalline diamond using state-of-the-art nanofabrication. The required precision alignment and calibration at the picometer level also appear to be feasible. With 100 nm grating pitch, a 10% measurement of $\bar{g}$ can be made using some months of surface-muon beam time, and a 1% or better measurement with a correspondingly larger exposure. This could constitute the first gravitational measurement of leptonic matter, of 2nd-generation matter and, possibly, the first measurement of the gravitational acceleration of antimatter.

preprint2016arXiv

Laser Spectroscopy of Muonic Atoms and Ions

Laser spectroscopy of the Lamb shift (2S-2P energy difference) in light muonic atoms or ions, in which one negative muon $μ^-$ is bound to a nucleus, has been performed. The measurements yield significantly improved values of the root-mean-square charge radii of the nuclei, owing to the large muon mass, which results in a vastly increased muon wave function overlap with the nucleus. The values of the proton and deuteron radii are 10 and 3 times more accurate than the respective CODATA values, but 7 standard deviations smaller. Data on muonic helium-3 and -4 ions is being analyzed and will give new insights. In future, the (magnetic) Zemach radii of the proton and the helium-3 nuclei will be determined from laser spectroscopy of the 1S hyperfine splittings, and the Lamb shifts of muonic Li, Be and B can be used to improve the respective charge radii.

preprint2016arXiv

Progress Towards a Muonium Gravity Experiment

The gravitational acceleration of antimatter, $\bar g$, has yet to be directly measured but could change our understanding of gravity, the Universe, and the possibility of a fifth force. Three avenues are apparent for such a measurement: antihydrogen, positronium, and muonium, the last requiring a precision atom interferometer and benefiting from a novel muonium beam under development. The interferometer and its few-picometer alignment and calibration systems appear to be feasible. With 100 nm grating pitch, measurements of $\bar g$ to 10%, 1%, or better can be envisioned. This could constitute the first gravitational measurement of leptonic matter, of second-generation matter and, possibly, the first measurement of the gravitational acceleration of antimatter.

preprint2016arXiv

Slow Muons and Muonium

The Paul Scherrer Institut in Switzerland operates the high intensity proton accelerator facility HIPA. A 590 MeV kinetic energy proton beam of presently up to 2.4 mA is sent to target stations producing pions, muons and neutrons for fundamental and applied physics. The beam power of 1.4 MW provides the world's highest intensities of low momentum muons which can be stopped in low mass targets. Rates of surface muons of up to about $10^8$/s are being provided to various unique precision particle physics experiments. Two feasibility studies are ongoing to considerably improve the available muon beams. The high intensity muon beamline, HiMB, could deliver on the order of $10^{10}$/s surface muons and the stopped muon cooler, muCool, aims at a gain factor of $10^{10}$ in phase space quality while sacrificing only less than 3 orders of magnitude in intensity for low energy $μ^+$. These beams will allow a new generation of precision physics experiments with stopped muons and muonium atoms.

preprint2016arXiv

Thin-disk laser scaling limit due to thermal-lens induced misalignment instability

We present an obstacle in power scaling of thin-disk lasers related with self-driven growth of misalignment due to thermal lens effects. This self-driven growth arises from the changes of the optical phase difference at the disk caused by the excursion of the laser eigen-mode from the optical axis. We found a criterion based on a simplified model of this phenomenon which can be applied to design laser resonators insensitive to this effect. Moreover, we propose several resonator architectures which are not affected by this effect.

preprint2015arXiv

Geant4 simulation of the PSI LEM beam line: energy loss and muonium formation in thin foils and the impact of unmoderated muons on the $μ$SR spectrometer

The PSI low-energy $μ$SR spectrometer is an instrument dedicated to muon spin rotation and relaxation measurements. Knowledge of the muon beam parameters such as spatial, kinetic energy and arrival-time distributions at the sample position are important ingredients to analyze the $μ$SR spectra. We present here the measured energy losses in the thin carbon foil of the muon start detector deduced from time-of-flight measurements. Muonium formation in the thin carbon foil (10 nm thickness) of the muon start detector also affect the measurable decay asymmetry and therefore need to be accounted for. Muonium formation and energy losses in the start detector, whose relevance increase with decreasing muon implantation energy ($<10$ keV), have been implemented in Geant4 Monte Carlo simulation to reproduce the measured time-of-flight spectra. Simulated and measured time-of-flight and beam spot agrees only if a small fraction of so called "unmoderated" muons which contaminate the mono-energetic muon beam of the $μ$SR spectrometer is introduced. Moreover the sensitivity of the beam size and related upstream-downstream asymmetry for a specially shaped "nose" sample plate has been studied for various beam line settings, which is of relevance for the study of thermal muonium emission into vacuum from mesoporous silica at cryogenic temperatures.

preprint2015arXiv

Improved X-ray detection and particle identification with avalanche photodiodes

Avalanche photodiodes are commonly used as detectors for low energy x-rays. In this work we report on a fitting technique used to account for different detector responses resulting from photo absorption in the various APD layers. The use of this technique results in an improvement of the energy resolution at 8.2 keV by up to a factor of 2, and corrects the timing information by up to 25 ns to account for space dependent electron drift time. In addition, this waveform analysis is used for particle identification, e.g. to distinguish between x-rays and MeV electrons in our experiment.

preprint2015arXiv

Testing antimatter gravity with muonium

The debate about how antimatter or different antimatter systems behave gravitationally will be ultimately decided by experiments measuring directly the acceleration of various antimatter probes in the gravitational field of the Earth or perhaps redshift effects in antimatter atoms caused by the annual variation of the Sun's gravitational potential at the location of the Earth. Muonium atoms may be used to probe the gravitational interaction of leptonic, second generation antimatter. We discuss the progress of our work towards enabling such experiments with muonium.

preprint2014arXiv

Measuring Antimatter Gravity with Muonium

The gravitational acceleration of antimatter, $\bar{g}$, has never been directly measured and could bear importantly on our understanding of gravity, the possible existence of a fifth force, and the nature and early history of the universe. Only two avenues for such a measurement appear to be feasible: antihydrogen and muonium. The muonium measurement requires a novel, monoenergetic, low-velocity, horizontal muonium beam directed at an atom interferometer. The precision three-grating interferometer can be produced in silicon nitride or ultrananocrystalline diamond using state-of-the-art nanofabrication. The required precision alignment and calibration at the picometer level also appear to be feasible. With 100 nm grating pitch, a 10% measurement of $\bar{g}$ can be made using some months of surface-muon beam time, and a 1% or better measurement with a correspondingly larger exposure. This could constitute the first gravitational measurement of leptonic matter, of 2nd-generation matter and, possibly, the first measurement of the gravitational acceleration of antimatter.

preprint2014arXiv

Muon cooling: longitudinal compression

A 10 MeV/c $μ^+$ beam was stopped in helium gas of a few mbar in a magnetic field of 5 T. The muon 'swarm' has been efficiently compressed from a length of 16 cm down to a few mm along the magnetic field axis (longitudinal compression) using electrostatic fields. The simulation reproduces the low energy interactions of slow muons in helium gas. Phase space compression occurs on the order of microseconds, compatible with the muon lifetime of 2 $μ$s. This paves the way for preparation of a high quality muon beam.

preprint2013arXiv

Measuring Antimatter Gravity with Muonium

We consider a measurement of the gravitational acceleration of antimatter, gbar, using muonium. A monoenergetic, low-velocity, horizontal muonium beam will be formed from a surface-muon beam using a novel technique and directed at an atom interferometer. The measurement requires a precision three-grating interferometer: the first grating pair creates an interference pattern which is analyzed by scanning the third grating vertically using piezo actuators. State-of-the-art nanofabrication can produce the needed membrane grating structure in silicon nitride or ultrananoscrystalline diamond. With 100 nm grating pitch, a 10% measurement of gbar can be made using some months of surface-muon beam time. This will be the first gravitational measurement of leptonic matter, of 2nd-generation matter and, possibly, the first measurement of the gravitational acceleration of antimatter.