Source author record

Kenji Mishima

Kenji Mishima appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

A Novel Nuclear Emulsion Detector for Measurement of Quantum States of Ultracold Neutrons in the Earth's Gravitational Field

Hypothetical short-range interactions could be detected by measuring the wavefunctions of ultracold neutrons (UCNs) on a mirror bounded by the Earth's gravitational field. The Searches require detectors with higher spatial resolution. We are developing a UCN detector for the with a high spatial resolution, which consists of a Si substrate, a thin converter layer including $^{10}$B$_{4}$C, and a layer of fine-grained nuclear emulsion. Its resolution was estimated to be less than 100 nm by fitting tracks of either $^{7}$Li nuclei or $α$-particles, which were created when neutrons interacted with the $^{10}$B$_{4}$C layer. For actual measurements of the spatial distributions, the following two improvements were made: The first was to establish a method to align microscopic images with high accuracy within a wide region of 65 mm $\times$ 0.2 mm. We created reference marks of 1 $μ$m and 5 $μ$m diameter with an interval of 50 $μ$m and 500 $μ$m, respectively, on the Si substrate by electron beam lithography and realized a position accuracy of less than 30 nm. The second was to build a holder that could maintain the atmospheric pressure around the nuclear emulsion to utilize it under vacuum during exposure to UCNs. The intrinsic resolution of the improved detector was estimated by evaluating the blur of a transmission image of a gadolinium grating taken by cold neutrons as better than 0.56 $\pm$ 0.08 $μ$m, which included the grating accuracy. A test exposure to UCNs was conducted to obtain the spatial distribution of UCNs in the Earth's gravitational field. Although the test was successful, a blurring of 6.9 $μ$m was found in the measurements, compared with a theoretical curve. We identified the blurring caused by the refraction of UCNs due to the roughness of the upstream surface of the substrate. Polishing of the surface makes the resolution less than 100 nm.

preprint2020arXiv

Neutron scattering cross section of diamond nanoparticle

Due to their large coherent scattering cross section, diamond nanoparticles (DNPs) are considered as a promising candidate material for a new neutron reflector. For investigation of scattering cross sections of packed samples, we have developed a technique for mechanical compression of DNP powder. Application of 220 MPa allowed us to increase the bulk density from 0.40 g/cm$^3$ to 1.1 g/cm$^3$. The differential cross sections of uncompressed and packed samples were measured using the high-intensity total diffractometer instrument NOVA at J-PARC, covering transfer wavenumbers (q) from 0.6 to 100 nm$^{-1}$. The q dependence for the compressed sample agreed with the theoretical expectation derived from the Born approximation applied to homogeneous spheres with inclusion of a hard-sphere model to account for the inter-particle structure, whereas the results obtained from the powder sample disagreed. This implies that the theoretical description does not well represent the mesoscopic structure of the DNP powder sample.