Source author record

Go Ichikawa

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

1works
3topics
4close collaborators

Published work

1 publications

preprint2022arXiv

A Novel Nuclear Emulsion Detector for Measurement of Quantum States of Ultracold Neutrons in the Earth's Gravitational Field

Hypothetical short-range interactions could be detected by measuring the wavefunctions of ultracold neutrons (UCNs) on a mirror bounded by the Earth's gravitational field. The Searches require detectors with higher spatial resolution. We are developing a UCN detector for the with a high spatial resolution, which consists of a Si substrate, a thin converter layer including 10^{10}B4_{4}C, and a layer of fine-grained nuclear emulsion. Its resolution was estimated to be less than 100 nm by fitting tracks of either 7^{7}Li nuclei or αα-particles, which were created when neutrons interacted with the 10^{10}B4_{4}C layer. For actual measurements of the spatial distributions, the following two improvements were made: The first was to establish a method to align microscopic images with high accuracy within a wide region of 65 mm ×\times 0.2 mm. We created reference marks of 1 μμm and 5 μμm diameter with an interval of 50 μμm and 500 μμm, respectively, on the Si substrate by electron beam lithography and realized a position accuracy of less than 30 nm. The second was to build a holder that could maintain the atmospheric pressure around the nuclear emulsion to utilize it under vacuum during exposure to UCNs. The intrinsic resolution of the improved detector was estimated by evaluating the blur of a transmission image of a gadolinium grating taken by cold neutrons as better than 0.56 ±\pm 0.08 μμm, which included the grating accuracy. A test exposure to UCNs was conducted to obtain the spatial distribution of UCNs in the Earth's gravitational field. Although the test was successful, a blurring of 6.9 μμm was found in the measurements, compared with a theoretical curve. We identified the blurring caused by the refraction of UCNs due to the roughness of the upstream surface of the substrate. Polishing of the surface makes the resolution less than 100 nm.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.