Source author record

Ken Suzuki

Ken Suzuki appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

8works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2013arXiv

Efficiency and uniformity measurements of a light concentrator in combination with a SiPM array

A position sensitive Cherenkov detector was built, consisting of 64 SiPMs with an active area of 3x3 mm^2 and a pixel size of 100x100 μm^2. The sensitive area is increased by a light concentrator which consists of 64 pyramid-shaped funnels. These funnels have an entrance area of 7x7 mm^2 and an exit area of 3x3 mm^2, guaranteeing a sufficient position resolution e.g. for the barrel DIRC detector of the PANDA experiment at FAIR. The efficiency and uniformity of the light concentrator in combination with the SiPM array was tested by scanning the array in two dimensions, using a pulsed light beam. Results of these tests and comparison with simulations are given here.

preprint2013arXiv

New Approaches for Improvement of TOF-PET

We present results of simulations on the influence of photon propagation and the Cherenkov effect on the time resolution of LSO:Ce scintillators. The influence of the scintillator length on the coincidence time resolution is shown. Furthermore, the impact of the depth of interaction on the time resolution, the light output and the arrival time distribution at the photon detector is simulated and it is shown how these information can be used for time walk correction.

preprint2012arXiv

Feasibility Study of Observing eta' Mesic Nuclei with (p,d) Reaction

A novel method is proposed to measure eta'(958) meson bound states in 11C nuclei by missing mass spectroscopy of the 12C(p,d) reaction near the eta' production threshold. It is shown that peak structures will be observed experimentally in an inclusive measurement in case that the in-medium eta' mass reduction is sufficiently large and that the decay width of eta' mesic states is narrow enough. Such a measurement will be feasible with the intense proton beam supplied by the SIS synchrotron at GSI combined with the good energy resolution of the fragment separator FRS.

preprint2012arXiv

Spectroscopy of eta' mesic nuclei with (p,d) reaction

We are going to perform an inclusive spectroscopy experiment of eta' mesic nuclei with the 12C(p,d) reaction to study in-medium properties of the eta' meson. In nuclear medium, the eta' meson mass may be reduced due to partial restoration of chiral symmetry. In case of sufficiently large mass reduction and small absorption width of eta' at normal nuclear density, peak structures of eta' mesic states in 11C will be observed near the eta' emission threshold even in an inclusive spectrum. The experiment will be carried out at GSI with proton beam supplied by SIS using FRS as a spectrometer. The detail of the experiment is described.

preprint2012arXiv

The K1.8BR spectrometer system at J-PARC

A new spectrometer system was designed and constructed at the secondary beam line K1.8BR in the hadron hall of J-PARC to investigate $\bar K N$ interactions and $\bar K$-nuclear bound systems. The spectrometer consists of a high precision beam line spectrometer, a liquid $^3$He/$^4$He/D$_2$ target system, a Cylindrical Detector System that surrounds the target to detect the decay particles from the target region, and a neutron time-of-flight counter array located $\sim$15 m downstream from the target position. Details of the design, construction, and performance of the detector components are described.

preprint2010arXiv

Application of Geiger-mode photo sensors in Cherenkov detectors

Silicon-based photosensors (SiPMs) working in the Geiger-mode represent an elegant solution for the readout of particle detectors working at low-light levels like Cherenkov detectors. Especially the insensitivity to magnetic fields makes this kind of sensors suitable for modern detector systems in subatomic physics which are usually employing magnets for momentum resolution. In our institute we are characterizing SiPMs of different manufacturers for selecting sensors and finding optimum operating conditions for given applications. Recently we designed and built a light concentrator prototype with 8x8 cells to increase the active photon detection area of an 8x8 SiPM (Hamamatsu MPPC S10931-100P) array. Monte Carlo studies, measurements of the collection efficiency, and tests with the MPPC were carried out. The status of these developments are presented.

preprint2010arXiv

Silicon photomultiplier timing performance study

Many characteristics of Silicon Photomultipliers can be tuned with temperature and operation voltage. We present preliminary results of a study of the effect of these two operation parameters on the time resolution of large active area Multi-Pixel Photon Counters (MPPCs) manufactured by Hamamatsu. Measurements at -10 C, 0 C, and 10 C at different bias voltages were performed. The time resolution is best at low temperature and high over-voltage. Most significant improvements can be achieved in cases with low number of fired pixels (<10 pixels). Between the worst and best case among the considered conditions a factor of 5 improvement was observed. In cases with large number of fired pixels (>40 pixels) the effect of temperature and operation voltage becomes smaller. The timing performance still improves with decreasing temperature (~ factor of 2) but it hardly depends on the operation voltage. The study shows, that especially in applications where only few photons are available for detection a careful optimization of temperature and operation voltage are advisable to obtain optimum timing results with the MPPC.

preprint2009arXiv

Development of a GEM-TPC prototype

The use of GEM foils for the amplification stage of a TPC instead of a con- ventional MWPC allows one to bypass the necessity of gating, as the backdrift is suppressed thanks to the asymmetric field configuration. This way, a novel continuously running TPC, which represents one option for the PANDA central tracker, can be realized. A medium sized prototype with a diameter of 300 mm and a length of 600 mm will be tested inside the FOPI spectrometer at GSI using a carbon or lithium beam at intermediate energies (E = 1-3AGeV). This detector test under realistic experimental conditions should allow us to verify the spatial resolution for single tracks and the reconstruction capability for displaced vertexes. A series of physics measurement implying pion beams is scheduled with the FOPI spectrometer together with the GEM-TPC as well.