Researcher profile

Ken Suzuki

Ken Suzuki contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2012arXiv

Feasibility Study of Observing eta' Mesic Nuclei with (p,d) Reaction

A novel method is proposed to measure eta'(958) meson bound states in 11C nuclei by missing mass spectroscopy of the 12C(p,d) reaction near the eta' production threshold. It is shown that peak structures will be observed experimentally in an inclusive measurement in case that the in-medium eta' mass reduction is sufficiently large and that the decay width of eta' mesic states is narrow enough. Such a measurement will be feasible with the intense proton beam supplied by the SIS synchrotron at GSI combined with the good energy resolution of the fragment separator FRS.

preprint2012arXiv

The K1.8BR spectrometer system at J-PARC

A new spectrometer system was designed and constructed at the secondary beam line K1.8BR in the hadron hall of J-PARC to investigate $\bar K N$ interactions and $\bar K$-nuclear bound systems. The spectrometer consists of a high precision beam line spectrometer, a liquid $^3$He/$^4$He/D$_2$ target system, a Cylindrical Detector System that surrounds the target to detect the decay particles from the target region, and a neutron time-of-flight counter array located $\sim$15 m downstream from the target position. Details of the design, construction, and performance of the detector components are described.

preprint2010arXiv

Application of Geiger-mode photo sensors in Cherenkov detectors

Silicon-based photosensors (SiPMs) working in the Geiger-mode represent an elegant solution for the readout of particle detectors working at low-light levels like Cherenkov detectors. Especially the insensitivity to magnetic fields makes this kind of sensors suitable for modern detector systems in subatomic physics which are usually employing magnets for momentum resolution. In our institute we are characterizing SiPMs of different manufacturers for selecting sensors and finding optimum operating conditions for given applications. Recently we designed and built a light concentrator prototype with 8x8 cells to increase the active photon detection area of an 8x8 SiPM (Hamamatsu MPPC S10931-100P) array. Monte Carlo studies, measurements of the collection efficiency, and tests with the MPPC were carried out. The status of these developments are presented.

preprint2010arXiv

Silicon photomultiplier timing performance study

Many characteristics of Silicon Photomultipliers can be tuned with temperature and operation voltage. We present preliminary results of a study of the effect of these two operation parameters on the time resolution of large active area Multi-Pixel Photon Counters (MPPCs) manufactured by Hamamatsu. Measurements at -10 C, 0 C, and 10 C at different bias voltages were performed. The time resolution is best at low temperature and high over-voltage. Most significant improvements can be achieved in cases with low number of fired pixels (<10 pixels). Between the worst and best case among the considered conditions a factor of 5 improvement was observed. In cases with large number of fired pixels (>40 pixels) the effect of temperature and operation voltage becomes smaller. The timing performance still improves with decreasing temperature (~ factor of 2) but it hardly depends on the operation voltage. The study shows, that especially in applications where only few photons are available for detection a careful optimization of temperature and operation voltage are advisable to obtain optimum timing results with the MPPC.