Source author record

Johann Marton

Johann Marton appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

10works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2022arXiv

Experimental test of Non-Commutative Quantum Gravity by VIP-2 Lead

Pauli Exclusion Principle (PEP) violations induced by space-time non-commutativity, a class of universality for several models of Quantum Gravity, are investigated by the VIP-2 Lead experiment at the Gran Sasso underground National Laboratory of INFN. The VIP-2 Lead experimental bound on the non-commutative space-time scale $Λ$ excludes $θ$-Poincaré far above the Planck scale for non vanishing ``electric-like" components of $θ_{μν}$, and up to $6.9 \cdot 10^{-2}$ Planck scales if they are null. Therefore, this new bound represents the tightest one so far provided by atomic transitions tests. This result strongly motivates high sensitivity underground X-ray measurements as critical tests of Quantum Gravity and of the very microscopic space-time structure.

preprint2022arXiv

First Results for the pLGAD Sensor for Low-Penetrating Particles

Silicon sensors are the go-to technology for high-precision sensors in particle physics. But only recently low-noise silicon sensors with internal amplification became available. The so-called Low Gain Avalanche Detector (LGAD) sensors have been developed for applications in High Energy Physics, but lack two characteristics needed for the measurement of low-energy protons (<60 keV): a thin entrance window (in the order of tens of nm) and the efficient amplification of signals created near the sensor's surface (in a depth below 1 um). In this paper we present the so-called proton Low Gain Avalanche Detector (pLGAD) sensor concept and some results from characterization of the first prototypes of the sensor. The pLGAD is specifically designed to detect low-energy protons, and other low-penetrating particles. It will have a higher detection efficiency than non-silicon technologies, and promises to be a lot cheaper and easier to operate than competing silicon technologies.

preprint2016arXiv

Low-energy Antikaon Interaction with Nuclei: The AMADEUS Challenge

The low-energy strong interaction of antikaons (K-) with nuclei has many facets and rep- resents a lively and challenging research field. It is interconnected to the peculiar role of strangeness, since the strange quark is rather light, but still much heavier than the up and down quarks. Thus, when strangeness is involved one has to deal with spontaneous and explicit symmetry breaking in QCD. It is well known that the antikaon interaction with nucleons is attractive, but how strong ? Is the interaction strong enough to bind nucleons to form kaonic nuclei and, if so, what are the properties (binding energy, decay width)? There are controversial indications for such bound states and new results are expected to come soon. The existence of antikaon mediated bound states might have important consequences since it would open the possibility for the formation of cold baryonic matter of high density which might have a severe impact in astrophysics for the understanding of the composi- tion of compact (neutron) stars. New experimental opportunities could be provided by the AMADEUS experiment at the DA?NE electron-positron collider at LNF-INFN (Frascati, Italy). Pre-AMADEUS studies on the antikaon interaction with nuclei are carried out by analysis of data collected by KLOE in till 2005 and in special data runs using a carbon target insert. Studies for the dedicated AMADEUS detector setup taking advantage of the low-energy antikaons from Phi-meson decay delivered by DAFNE are in progress. Some re- sults obtained so far and the perspectives of the AMADEUS experiment are presented and discussed.

preprint2015arXiv

Search for the deeply bound $K^-pp$ state from the semi-inclusive forward-neutron spectrum in the in-flight $K^-$ reaction on helium-3

An experiment to search for the $K^-pp$ bound state was performed via the in-flight $^3$He($K^-,n)$ reaction using 5.3 $\times$ $10^9$ kaons at 1 GeV/$c$ at the J-PARC hadron experimental facility. In the semi-inclusive neutron missing-mass spectrum at $θ_{n}^{lab}=0^\circ$, no significant peak was observed in the region corresponding to $K^-pp$ binding energy larger than 80 MeV, where a bump structure has been reported in the $Λp$ final state in different reactions. Assuming the state to be isotropically decaying into $Λp$, mass-dependent upper limits on the production cross section were determined to be 30--180, 70--250, and 100--270 $μ$b/sr, for the natural widths of 20, 60, and 100 MeV, respectively, at 95\% confidence level.

preprint2013arXiv

Efficiency and uniformity measurements of a light concentrator in combination with a SiPM array

A position sensitive Cherenkov detector was built, consisting of 64 SiPMs with an active area of 3x3 mm^2 and a pixel size of 100x100 μm^2. The sensitive area is increased by a light concentrator which consists of 64 pyramid-shaped funnels. These funnels have an entrance area of 7x7 mm^2 and an exit area of 3x3 mm^2, guaranteeing a sufficient position resolution e.g. for the barrel DIRC detector of the PANDA experiment at FAIR. The efficiency and uniformity of the light concentrator in combination with the SiPM array was tested by scanning the array in two dimensions, using a pulsed light beam. Results of these tests and comparison with simulations are given here.

preprint2013arXiv

New Approaches for Improvement of TOF-PET

We present results of simulations on the influence of photon propagation and the Cherenkov effect on the time resolution of LSO:Ce scintillators. The influence of the scintillator length on the coincidence time resolution is shown. Furthermore, the impact of the depth of interaction on the time resolution, the light output and the arrival time distribution at the photon detector is simulated and it is shown how these information can be used for time walk correction.

preprint2012arXiv

The K1.8BR spectrometer system at J-PARC

A new spectrometer system was designed and constructed at the secondary beam line K1.8BR in the hadron hall of J-PARC to investigate $\bar K N$ interactions and $\bar K$-nuclear bound systems. The spectrometer consists of a high precision beam line spectrometer, a liquid $^3$He/$^4$He/D$_2$ target system, a Cylindrical Detector System that surrounds the target to detect the decay particles from the target region, and a neutron time-of-flight counter array located $\sim$15 m downstream from the target position. Details of the design, construction, and performance of the detector components are described.

preprint2010arXiv

Application of Geiger-mode photo sensors in Cherenkov detectors

Silicon-based photosensors (SiPMs) working in the Geiger-mode represent an elegant solution for the readout of particle detectors working at low-light levels like Cherenkov detectors. Especially the insensitivity to magnetic fields makes this kind of sensors suitable for modern detector systems in subatomic physics which are usually employing magnets for momentum resolution. In our institute we are characterizing SiPMs of different manufacturers for selecting sensors and finding optimum operating conditions for given applications. Recently we designed and built a light concentrator prototype with 8x8 cells to increase the active photon detection area of an 8x8 SiPM (Hamamatsu MPPC S10931-100P) array. Monte Carlo studies, measurements of the collection efficiency, and tests with the MPPC were carried out. The status of these developments are presented.

preprint2010arXiv

Silicon photomultiplier timing performance study

Many characteristics of Silicon Photomultipliers can be tuned with temperature and operation voltage. We present preliminary results of a study of the effect of these two operation parameters on the time resolution of large active area Multi-Pixel Photon Counters (MPPCs) manufactured by Hamamatsu. Measurements at -10 C, 0 C, and 10 C at different bias voltages were performed. The time resolution is best at low temperature and high over-voltage. Most significant improvements can be achieved in cases with low number of fired pixels (<10 pixels). Between the worst and best case among the considered conditions a factor of 5 improvement was observed. In cases with large number of fired pixels (>40 pixels) the effect of temperature and operation voltage becomes smaller. The timing performance still improves with decreasing temperature (~ factor of 2) but it hardly depends on the operation voltage. The study shows, that especially in applications where only few photons are available for detection a careful optimization of temperature and operation voltage are advisable to obtain optimum timing results with the MPPC.

preprint2009arXiv

Development of a GEM-TPC prototype

The use of GEM foils for the amplification stage of a TPC instead of a con- ventional MWPC allows one to bypass the necessity of gating, as the backdrift is suppressed thanks to the asymmetric field configuration. This way, a novel continuously running TPC, which represents one option for the PANDA central tracker, can be realized. A medium sized prototype with a diameter of 300 mm and a length of 600 mm will be tested inside the FOPI spectrometer at GSI using a carbon or lithium beam at intermediate energies (E = 1-3AGeV). This detector test under realistic experimental conditions should allow us to verify the spatial resolution for single tracks and the reconstruction capability for displaced vertexes. A series of physics measurement implying pion beams is scheduled with the FOPI spectrometer together with the GEM-TPC as well.