Source author record

Kate Grieve

Kate Grieve appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2021arXiv

Optical phase modulation by natural eye movements: application to time-domain FF-OCT image retrieval

Eye movements are commonly seen as an obstacle to high-resolution ophthalmic imaging. In this context we study the natural axial movements of the in vivo human eye and show that they can be used to modulate the optical phase and retrieve tomographic images via time-domain full-field optical coherence tomography (TD-FF-OCT). This approach opens a path to a simplified ophthalmic TD-FF-OCT device, operating without the usual piezo motor-camera synchronization. The device demonstrates in vivo human corneal images under the different image retrieval schemes (2-phase and 4-phase) and different exposure times (3.5 ms, 10 ms, 20 ms). Data on eye movements, acquired with a 100 kHz spectral-domain OCT with axial eye tracking, are used to study the influence of ocular motion on the probability of capturing high-signal tomographic images without phase washout. The optimal combinations of camera acquisition speed and amplitude of piezo modulation are proposed and discussed.

preprint2020arXiv

Optical Incoherence Tomography: a method to generate tomographic retinal cross-sections with non-interferometric imaging systems

Optical tomographic cross-sectional images of biological samples were made possible by interferometric imaging techniques such as Optical Coherence Tomography (OCT). Owing to its unprecedented view of the sample, OCT has become a gold standard, namely for human retinal imaging in the clinical environment. In this Letter, we present Optical Incoherence Tomography (OIT): a completely digital method extending the possibility to generate tomographic retinal cross-sections to non-interferometric imaging systems such as en-face AO-ophthalmoscopes. We demonstrate that OIT can be applied to different imaging modalities using back-scattered and multiply-scattered light including systems without inherent optical sectioning. We show that OIT can be further used to guide focus position when the user is "blind" focusing, allowing precise imaging of translucent retinal structures, the vascular plexuses and the retinal pigment epithelium using respectively split detection, motion contrast, and autofluorescence techniques.

preprint2020arXiv

Real-time, non-contact, cellular imaging and angiography of human cornea and limbus with common-path Full-field/SDOCT

In today's clinics, a cellular-resolution view of the cornea can be achieved only with an in vivo confocal microscope (IVCM) in contact with the eye. Here, we present a common-path Full-field/Spectral-domain OCT microscope (FF/SD OCT), which, for the first time, enables cell-detail imaging of the entire ocular surface (central and peripheral cornea, limbus, sclera, tear film) without contact and in real time. The device, which has been successfully tested in human subjects, is now ready for direct implementation in clinical research. Real-time performance is achieved through rapid axial eye tracking and simultaneous defocusing correction. Images, extracted from real-time videos, contain cells and nerves, which can be quantified over a millimetric field-of-view, beyond the capability of IVCM and conventional OCT. In the limbus, Palisades of Vogt, vessels and blood flow can be resolved with high contrast without contrast agent injection. The fast imaging speed of 275 frames/s (0.6 billion pixels/s) allowed direct monitoring of blood flow dynamics, enabling creation of high-resolution velocity maps for the first time. Tear flow velocity and evaporation time could be measured without fluorescein administration.

preprint2013arXiv

Imaging of non tumorous and tumorous human brain tissue with full-field optical coherence tomography

A prospective study was performed on neurosurgical samples from 18 patients to evaluate the use of Full-Field Optical Coherence Tomography (FF-OCT) in brain tumor diagnosis. FF-OCT captures en face slices of tissue samples at 1\mum resolution in 3D with a typical 200\mum imaging depth. A 1cm2 specimen is scanned at a single depth and processed in about 5 minutes. This rapid imaging process is non-invasive and 30 requires neither contrast agent injection nor tissue preparation, which makes it particularly well suited to medical imaging applications. Temporal chronic epileptic parenchyma and brain tumors such as meningiomas, low- grade and high-grade gliomas, and choroid plexus papilloma were imaged. A subpopulation of neurons, myelin fibers and CNS vasculature were clearly identified. Cortex could be discriminated from white matter, but individual glial cells as astrocytes (normal or reactive) or oligodendrocytes were not observable. This study reports for the first time on the feasibility of using FF-OCT in a real-time manner as a label-free non-invasive imaging technique in an intra-operative neurosurgical clinical setting to assess tumorous glial and epileptic margins.