Researcher profile

Karel Zidek

Karel Zidek contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

Beating signals in CdSe quantum dots measured by low-temperature 2D spectroscopy

Advances in ultrafast spectroscopy can provide access to dynamics involving nontrivial quantum correlations and their evolutions. In coherent 2D spectroscopy, the oscillatory time dependence of a signal is a signature of such quantum dynamics. Here we study such beating signals in electronic coherent 2D spectroscopy of CdSe quantum dots (CdSe QDs) at 77 K. The beating signals are analyzed in terms of their positive and negative Fourier components. We conclude that the beatings originate from coherent LO-phonons of CdSe QDs. No evidence for the quantum dot size dependence of the LO-phonon frequency was identified.

preprint2022arXiv

Differential Coded Aperture Single-Snapshot Spectral Imaging

We propose a novel concept of differential coded aperture snapshot spectral imaging (D-CASSI) technique exploiting the benefits of using {-1,+1} random mask, which is demonstrated by a broadband single-snapshot hyperspectral camera using compressed sensing. To double the information, we encode the image by two complementary random masks, which proved to be superior to two independent patterns. We utilize dispersed and non-dispersed encoded images captured in parallel onto a single detector. We explored several different approaches to processing the measured data, which demonstrates significant improvement in retrieving complex hyperspectral scenes. The experiments were completed by simulations in order to quantify the reconstruction fidelity. The concept of differential CASSI could be easily implemented also by multi-snapshot CASSI without any need for optical system modification.

preprint2022arXiv

Enhancement of CASSI by a zero-order image employing a single detector

Coded aperture snapshot spectral imaging (CASSI) makes it possible to recover 3D hyperspectral data from a single 2D image. However, the reconstruction problem is severely underdetermined and efforts to improve the compression ratio typically make the imaging system more complex and cause a significant loss of incoming light intensity. In this paper, we propose a novel approach to CASSI which enables capturing both spectrally sheared and integrated image of a scene with a single camera. We performed hyperspectral imaging of three different testing scenes in the spectral range of 500-900 nm. We demonstrate the prominent effect of using the non-diffracted image on the reconstruction of data from our camera. The use of the spectrally integrated image improves the reconstruction quality and we observed an approx. fivefold reduction in reconstruction time.

preprint2021arXiv

Noise effect on 2D photoluminescence decay analysis using the RATS method in single-pixel camera configuration

Using a random temporal signal for sample excitation (RATS method) is a new, efficient approach to measuring photoluminescence (PL) dynamics. The method can be used in single-point measurement (0D), but also it can be converted to PL decay imaging (2D) using a single-pixel camera configuration. In both cases, the reconstruction of the PL decay and PL snapshot is affected by ubiquitous noise. This article provides a detailed analysis of the noise effect on the RATS method and possible strategies for its elimination. We carried out an extensive set of simulations focusing on the effect of noise introduced through the random excitation signal and the corresponding PL waveform. We show that the PL signal noise level is critical for the method. Furthermore, we analyze the role of acquisition time, where we demonstrate the need for a non-periodic excitation signal. We show that it is beneficial to increase the acquisition time while increasing the number of measurements in the single-pixel camera configuration has a minimal effect above a certain threshold. Finally, we study the effect of a regularization parameter used in the deconvolution step, and we observe that there is an optimum value set by the noise present in the PL dataset. Our results provide a guideline for optimization of the RATS measurement, but also study effects generally occurring in PL decay measurements methods relying on the deconvolution step.

preprint2020arXiv

Collection of micromirror-modulated light in the single-pixel broadband hyperspectral microscope

Digital micromirror device (DMD) serves in a significant part of computational optical setups as a means of encoding an image by the desired pattern. The most prominent is its usage in the so-called single-pixel camera experiment. This experiment often requires an efficient and homogenous collection of light from a relatively large chip on a small area of an optical fiber or spectrometer slit. Moreover, this effort is complicated by the fact that the DMD acts as a diffractive element, which causes severe spectral inhomogeneities in the light collection. We studied the effect of light diffraction via a whiskbroom hyperspectral camera in a broad spectral range. Based on the knowledge, we designed a variety of different approaches to light collection. We mapped the efficiency and spectral homogeneity of each of the configuration - namely its ability to couple the light into commercially available fiber spectrometers working in the visible and IR range (up to 2500 nm). We found the integrating spheres to provide homogeneous light collection, which, however, suffers from very low efficiency. The best compromise between the performance parameters was provided by a combination of an engineered diffuser with an off-axis parabolic mirror. We used this configuration to create a computational microscope able to carry out hyperspectral imaging of a sample in a broad spectral range (400-2500 nm). We see such a setup as an ideal tool to carry out spectrally-resolved transmission microscopy in a broad spectral range.

preprint2020arXiv

Fluorescence lifetime imaging via spatio-temporal speckle patterns in single-pixel camera configuration

Photoluminesce (PL) spectroscopy offers excellent methods for mapping the PL decay on the nanosecond time scale. However, capturing maps of emission dynamics on the microsecond time scale can be highly time-consuming. We present a new approach to fluorescence lifetime imaging FLIM, which combines the concept of random temporal speckles excitation (RATS) with the concept of a single-pixel camera based on spatial speckles. The spatio-temporal speckle pattern makes it possible to map PL dynamics with unmatched simplicity. Moreover, the method can acquire all data necessary to map PL decays in the microsecond timescale within minutes. We present proof of principle measurements for two samples and compare the reconstructed decays to the non-imaging measurements. Finally, we discuss the effect of the preprocessing routine and other factors on the reconstruction noise level. The presented method is suitable for lifetime imaging processes in several samples, including charge carrier dynamics in perovskites or monitoring solid-state luminophores with a long lifetime of PL.

preprint2020arXiv

Random temporal laser speckles for robust measurement of sub-microsecond photoluminescence decay

Time-resolved photoluminescence (PL) is commonly used to track dynamics in a broad range of materials. Thus, the search for simplification of the acquisition of PL kinetics attracts continuous attention. This paper presents a new robust and straightforward approach to the measurement of PL decay, which is based on randomly fluctuating excitation intensity. The random excitation waveform is attained by using laser speckles generated on a rotating diffuser. Owing to this, the presented technique is able to utilize any coherent excitation source without the necessity to generate short pulses or to controllably modulate the light. PL decay can be computationally reconstructed from the Fourier image of the PL trace. The paper demonstrates the performance of the method, which is able to acquire sub-microsecond dynamics as the impulse response function reaches 300 ns. The reconstructed PL decays were compared to streak camera measurements to verify the method. Finally, potential limitations and applications of the technique are discussed.