Researcher profile

Kah Wuy Chin

Kah Wuy Chin contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Material properties of a low contraction and resistivity silicon-aluminum composite for cryogenic detectors

We report on the cryogenic properties of a low-contraction silicon-aluminum composite, namely Japan Fine Ceramics SA001, to use as a packaging structure for cryogenic silicon devices. SA001 is a silicon--aluminum composite material (75% silicon by volume) and has a low thermal expansion coefficient ($\sim$1/3 that of aluminum). The superconducting transition temperature of SA001 is measured to be 1.18 K, which is in agreement with that of pure aluminum, and is thus available as a superconducting magnetic shield material. The residual resistivity of SA001 is 0.065 $\mathrm{μΩm}$, which is considerably lower than an equivalent silicon--aluminum composite material. The measured thermal contraction of SA001 immersed in liquid nitrogen is $\frac{L_{293\mathrm{K}}-L_{77\mathrm{K}}}{L_{293\mathrm{K}}}=0.12$%, which is consistent with the expected rate obtained from the volume-weighted mean of the contractions of silicon and aluminum. The machinability of SA001 is also confirmed with a demonstrated fabrication of a conical feedhorn array, with a wall thickness of 100 $\mathrm{μm}$. These properties are suitable for packaging applications for large-format superconducting detector devices.

preprint2021arXiv

TiEMPO: Open-source time-dependent end-to-end model for simulating ground-based submillimeter astronomical observations

The next technological breakthrough in millimeter-submillimeter astronomy is 3D imaging spectrometry with wide instantaneous spectral bandwidths and wide fields of view. The total optimization of the focal-plane instrument, the telescope, the observing strategy, and the signal-processing software must enable efficient removal of foreground emission from the Earth's atmosphere, which is time-dependent and highly nonlinear in frequency. Here we present TiEMPO: Time-Dependent End-to-End Model for Post-process Optimization of the DESHIMA Spectrometer. TiEMPO utilizes a dynamical model of the atmosphere and parametrized models of the astronomical source, the telescope, the instrument, and the detector. The output of TiEMPO is a time-stream of sky brightness temperature and detected power, which can be analyzed by standard signal-processing software. We first compare TiEMPO simulations with an on-sky measurement by the wideband DESHIMA spectrometer and find good agreement in the noise power spectral density and sensitivity. We then use TiEMPO to simulate the detection of a line emission spectrum of a high-redshift galaxy using the DESHIMA 2.0 spectrometer in development. The TiEMPO model is open source. Its modular and parametrized design enables users to adapt it to design and optimize the end-to-end performance of spectroscopic and photometric instruments on existing and future telescopes.

preprint2020arXiv

Demonstration of wideband metal mesh filters for submillimeter astrophysics using flexible printed circuits

We developed a wideband quasi-optical band-pass filter covering 170-520 GHz by exploiting the recent advancements in commercially available flexible printed circuit (FPC) fabrication technologies. We designed and fabricated a three-layered stack of loaded hexagonal grid metal meshes using a copper pattern with a narrowest linewidth of $50~μ\mathrm{m}$ on a polyimide substrate. The measured frequency pass-band shape was successfully reproduced through a numerical simulation using a set of parameters consistent with the dimensions of the fabricated metal meshes. FPC-based metal mesh filters will provide a new pathway toward the on-demand development of millimeter/submillimeter-wave quasi-optical filters at low cost and with a short turnaround time.

preprint2020arXiv

DESHIMA on ASTE: On-sky Responsivity Calibration of the Integrated Superconducting Spectrometer

We are developing an ultra-wideband spectroscopic instrument, DESHIMA (DEep Spectroscopic HIgh-redshift MApper), based on the technologies of an on-chip filter-bank and Microwave Kinetic Inductance Detector (MKID) to investigate dusty star-burst galaxies in the distant universe at millimeter and submillimeter wavelength. An on-site experiment of DESHIMA was performed using the ASTE 10-m telescope. We established a responsivity model that converts frequency responses of the MKIDs to line-of-sight brightness temperature. We estimated two parameters of the responsivity model using a set of skydip data taken under various precipitable water vapor (PWV, 0.4-3.0 mm) conditions for each MKID. The line-of-sight brightness temperature of sky is estimated using an atmospheric transmission model and the PWVs. As a result, we obtain an average temperature calibration uncertainty of $1σ=4$%, which is smaller than other photometric biases. In addition, the average forward efficiency of 0.88 in our responsivity model is consistent with the value expected from the geometrical support structure of the telescope. We also estimate line-of-sight PWVs of each skydip observation using the frequency response of MKIDs, and confirm the consistency with PWVs reported by the Atacama Large Millimeter/submillimeter Array.