Researcher profile

K. Kanagawa

K. Kanagawa contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2021arXiv

A study on energy resolution of CANDLES detector

In a neutrinoless double-beta decay ($0νββ$) experiment, energy resolution is important to distinguish between $0νββ$ and background events. CAlcium fluoride for studies of Neutrino and Dark matters by Low Energy Spectrometer (CANDLES) discerns the $0νββ$ of $^{48}$Ca using a CaF$_2$ scintillator as the detector and source. Photomultiplier tubes (PMTs) collect scintillation photons. At the Q-value of $^{48}$Ca, the current energy resolution (2.6%) exceeds the ideal statistical fluctuation of the number of photoelectrons (1.6%). Because of CaF$_2$'s long decay constant of 1000 ns, a signal integration within 4000 ns is used to calculate the energy. The baseline fluctuation ($σ_{baseline}$) is accumulated in the signal integration, thus degrading the energy resolution. This paper studies $σ_{baseline}$ in the CANDLES detector, which severely degrades the resolution by 1% at the Q-value of $^{48}$Ca. To avoid $σ_{\rm baseline}$, photon counting can be used to obtain the number of photoelectrons in each PMT; however, a significant photoelectron signal overlapping probability in each PMT causes missing photoelectrons in counting and reduces the energy resolution. "Partial photon counting" reduces $σ_{baseline}$ and minimizes photoelectron loss. We obtain improved energy resolutions of 4.5-4.0% at 1460.8 keV ($γ$-ray of $^{40}$K), and 3.3-2.9% at 2614.5 keV ($γ$-ray of $^{208}$Tl). The energy resolution at the Q-value is estimated to be improved from 2.6% to 2.2%, and the detector sensitivity for the $0νββ$ half-life of $^{48}$Ca can be improved by 1.09 times.

preprint2014arXiv

Meridional circulation of gas into gaps opened by giant planets in three-dimensional low-viscosity disks

We examine the gas circulation near a gap opened by a giant planet in a protoplanetary disk. We show with high resolution 3D simulations that the gas flows into the gap at high altitude over the mid-plane, at a rate dependent on viscosity. We explain this observation with a simple conceptual model. From this model we derive an estimate of the amount of gas flowing into a gap opened by a planet with Hill radius comparable to the scale-height of a layered disk (i. e. a disk with viscous upper layer and inviscid midplane). Our estimate agrees with modern MRI simulations(Gressel et al., 2013). We conclude that gap opening in a layered disk can not slow down significantly the runaway gas accretion of Saturn to Jupiter-mass planets.