Source author record

B. T. Khai

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

2works
3topics
4close collaborators

Published work

2 publications

preprint2021arXiv

A study on energy resolution of CANDLES detector

In a neutrinoless double-beta decay (0νββ0νββ) experiment, energy resolution is important to distinguish between 0νββ0νββ and background events. CAlcium fluoride for studies of Neutrino and Dark matters by Low Energy Spectrometer (CANDLES) discerns the 0νββ0νββ of 48^{48}Ca using a CaF2_2 scintillator as the detector and source. Photomultiplier tubes (PMTs) collect scintillation photons. At the Q-value of 48^{48}Ca, the current energy resolution (2.6%) exceeds the ideal statistical fluctuation of the number of photoelectrons (1.6%). Because of CaF2_2's long decay constant of 1000 ns, a signal integration within 4000 ns is used to calculate the energy. The baseline fluctuation (σbaselineσ_{baseline}) is accumulated in the signal integration, thus degrading the energy resolution. This paper studies σbaselineσ_{baseline} in the CANDLES detector, which severely degrades the resolution by 1% at the Q-value of 48^{48}Ca. To avoid σbaselineσ_{\rm baseline}, photon counting can be used to obtain the number of photoelectrons in each PMT; however, a significant photoelectron signal overlapping probability in each PMT causes missing photoelectrons in counting and reduces the energy resolution. "Partial photon counting" reduces σbaselineσ_{baseline} and minimizes photoelectron loss. We obtain improved energy resolutions of 4.5-4.0% at 1460.8 keV (γγ-ray of 40^{40}K), and 3.3-2.9% at 2614.5 keV (γγ-ray of 208^{208}Tl). The energy resolution at the Q-value is estimated to be improved from 2.6% to 2.2%, and the detector sensitivity for the 0νββ0νββ half-life of 48^{48}Ca can be improved by 1.09 times.

preprint2020arXiv

Pulse Shape Discrimination of CsI(Tl) with a Photomultiplier Tube and MPPCs

In this study, we evaluate and compare the pulse shape discrimination (PSD) performance of multipixel photon counters (MPPCs, also known as silicon photomultiphers - SiPMs) with that of a typical photomultiplier tube (PMT) when testing using CsI(Tl) scintillators. We use the charge comparison method, whereby we discriminate different types of particles by the ratio of charges integrated within two time-gates (the delayed part and the entire digitized waveform). For a satisfactory PSD performance, a setup should generate many photoelectrons (p.e.) and collect their charges efficiently. The PMT setup generates more p.e. than the MPPC setup does. With the same digitizer and the same long time-gate (the entire digitized waveform), the PMT setup is also better in charge collection. Therefore, the PMT setup demonstrates better PSD performance. We subsequently test the MPPC setup using a new data acquisition (DAQ) system. Using this new DAQ, the long time-gate is extended by nearly four times the length when using the previous digitizer. With this longer time-gate, we collect more p.e. at the tail part of the pulse and almost all the charges of the total collected p.e. Thus, the PSD performance of the MPPC setup is improved significantly. This study also provides an estimation of the short time-gate (the delayed part of the digitized waveform) that can give a satisfactory PSD performance without an extensive analysis to optimize this gate.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.