Source author record

Junying Ma

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

2works
3topics
4close collaborators

Published work

2 publications

preprint2022arXiv

Low-frequency Phonon at Perovskite Oxide Interface Studied by Surface-specific Nonlinear Terahertz Spectroscopy

The low-frequency collective excitations, which often occur in the terahertz or multi-terahertz spectral region, play an essential role in many novel emergent phenomena. Despite numerous studies in the bulk, detection of such excitations at interfaces remains challenging owing to the lack of feasible experimental techniques. Here, we show that interfacial low-frequency modes can be characterized using surface-specific nonlinear terahertz spectroscopy. This technique uses intra-pulse difference frequency mixing (DFM) process that can extend the second-order optical spectroscopy to the terahertz range. As a demonstration, the surface phonon of SrTiO3(001) at 2.8 THz was successfully measured. This surface polarization originates from the excess of oxygen vacancies or charge transfer at the interface. We have also developed an analytical procedure for remote measurement of the interfacial potential of complex oxides in a practical environment. Our method offers new opportunities for in situ studies of the low-frequency excitations at interfaces in broad disciplines.

preprint2022arXiv

Measurement of DC Magneto-Optical Kerr Effect with Sensitivity of 10−7Rad/Hz10^{-7} \text{Rad}/\sqrt{\text{Hz}}

A high-sensitive DC Magneto-Optical Kerr Effect (MOKE) apparatus is described in this letter. Via detailed analysis on several dominating noise sources, we have proposed solutions that significantly lower the MOKE noise, and a sensitivity of 1.5×10−7rad/Hz1.5\times10^{-7} \text{rad}/\sqrt{\text{Hz}} is achieved with long-term stability. The sensitivity of the apparatus is tested by measuring a wedge-shaped Ni thin film on SiO2\text{SiO}_2 with Ni thickness varying from 0 to 3 nm. A noise floor of 1.5×10−81.5\times10^{-8} rad is demonstrated. The possibility of further improving sensitivity to 10−910^{-9} rad via applying ac modulation is also discussed.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.