Source author record

Junjian Qi

Junjian Qi appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

17works
10topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

17 published item(s)

preprint2021arXiv

A Stochastic Multi-Agent Optimization Framework for Interdependent Transportation and Power System Analyses

We study the interdependence between transportation and power systems considering decentralized renewable generators and electric vehicles (EVs). We formulate the problem in a stochastic multi-agent optimization framework considering the complex interactions between EV/conventional vehicle drivers, \revi{renewable}/conventional generators, and independent system operators, with locational electricity and charging prices endogenously determined by markets. We show that the multi-agent optimization problems can be reformulated as a single convex optimization problem and prove the existence and uniqueness of the equilibrium. To cope with the curse of dimensionality, we propose ADMM-based decomposition algorithm to facilitate parallel computing. Numerical insights are generated using standard test systems in transportation and power system literature.

preprint2020arXiv

Robust Dynamic State Estimation of Synchronous Machines with Asymptotic State Estimation Error Performance Guarantees

A robust observer for performing power system dynamic state estimation (DSE) of a synchronous generator is proposed. The observer is developed using the concept of $\mathcal{L}_{\infty}$ stability for uncertain, nonlinear dynamic generator models. We use this concept to (i) design a simple, scalable, and robust dynamic state estimator and (ii) obtain a performance guarantee on the state estimation error norm relative to the magnitude of uncertainty from unknown generator inputs, and process and measurement noises. Theoretical methods to obtain upper and lower bounds on the estimation error are also provided. Numerical tests validate the performance of the $\mathcal{L}_{\infty}$-based estimator in performing DSE under various scenarios. The case studies reveal that the derived theoretical bounds are valid for a variety of case studies and operating conditions, while yielding better performance than existing power system DSE methods.

preprint2019arXiv

Robust Cubature Kalman Filter for Dynamic State Estimation of Synchronous Machines under Unknown Measurement Noise Statistics

Kalman-type filtering techniques including cubature Kalman filter (CKF) does not work well in non-Gaussian environments, especially in the presence of outliers. To solve this problem, Huber's M-estimation based robust CKF (RCKF) is proposed for synchronous machines by combining the Huber's M-estimation theory with the classical CKF, which is capable of coping with the deterioration in performance and discretization of tracking curves when measurement noise statistics deviatefrom the prior noise statistics. The proposed RCKF algorithm has good adaptability to unknown measurement noise statistics characteristics including non-Gaussian measurement noise and outliers. The simulation results on the WSCC 3-machine 9-bus system and New England 16-machine 68-bus system verify the effectiveness of the proposed method and its advantage over the classical CKF.

preprint2016arXiv

Adaptive Optimal PMU Placement Based on Empirical Observability Gramian

In this paper, we compare four measures of the empirical observability gramian, including the determinant, the trace, the minimum eigenvalue, and the condition number, which can be used to quantify the observability of system states and to obtain the optimal PMU placement for power system dynamic state estimation. An adaptive optimal PMU placement method is proposed by automatically choosing proper measures as the objective function. It is shown that when the number of PMUs is small and thus the observability is very weak, the minimum eigenvalue and the condition number are better measures of the observability and are preferred to be chosen as the objective function. The effectiveness of the proposed method is validated by performing dynamic state estimation on an Northeast Power Coordinating Council (NPCC) 48-machine 140-bus system with the square-root unscented Kalman filter.

preprint2016arXiv

An SQP Method Combined with Gradient Sampling for Small-Signal Stability Constrained OPF

Small-Signal Stability Constrained Optimal Power Flow (SSSC-OPF) can provide additional stability measures and control strategies to guarantee the system to be small-signal stable. However, due to the nonsmooth property of the spectral abscissa function, existing algorithms solving SSSC-OPF cannot guarantee convergence. To tackle this computational challenge of SSSC-OPF, we propose a Sequential Quadratic Programming (SQP) method combined with Gradient Sampling (GS) for SSSCOPF.At each iteration of the proposed SQP, the gradient of the spectral abscissa unction is randomly sampled at the current iterate and additional nearby points to make the search direction computation effective in nonsmooth regions. The method can guarantee SSSC-OPF is globally and efficiently convergent to stationary points with probability one. The effectiveness of the proposed method is tested and validated on WSCC 3-machine 9-bus system, New England 10-machine 39-bus system, and IEEE 54-machine 118-bus system.

preprint2016arXiv

Dynamic State Estimation for Multi-Machine Power System by Unscented Kalman Filter with Enhanced Numerical Stability

In this paper, in order to enhance the numerical stability of the unscented Kalman filter (UKF) used for power system dynamic state estimation, a new UKF with guaranteed positive semidifinite estimation error covariance (UKF-GPS) is proposed and compared with five existing approaches, including UKF-schol, UKF-$κ$, UKF-modified, UKF-$ΔQ$, and the square-root unscented Kalman filter (SR-UKF). These methods and the extended Kalman filter (EKF) are tested by performing dynamic state estimation on WSCC 3-machine 9-bus system and NPCC 48-machine 140-bus system. For WSCC system, all methods obtain good estimates. However, for NPCC system, both EKF and the classic UKF fail. It is found that UKF-schol, UKF-$κ$, and UKF-$ΔQ$ do not work well in some estimations while UKF-GPS works well in most cases. UKF-modified and SR-UKF can always work well, indicating their better scalability mainly due to the enhanced numerical stability.

preprint2016arXiv

Estimating the Propagation of Interdependent Cascading Outages with Multi-Type Branching Processes

In this paper, the multi-type branching process is applied to describe the statistics and interdependencies of line outages, the load shed, and isolated buses. The offspring mean matrix of the multi-type branching process is estimated by the Expectation Maximization (EM) algorithm and can quantify the extent of outage propagation. The joint distribution of two types of outages is estimated by the multi-type branching process via the Lagrange-Good inversion. The proposed model is tested with data generated by the AC OPA cascading simulations on the IEEE 118-bus system. The largest eigenvalues of the offspring mean matrix indicate that the system is closer to criticality when considering the interdependence of different types of outages. Compared with empirically estimating the joint distribution of the total outages, good estimate is obtained by using the multitype branching process with a much smaller number of cascades, thus greatly improving the efficiency. It is shown that the multitype branching process can effectively predict the distribution of the load shed and isolated buses and their conditional largest possible total outages even when there are no data of them.

preprint2016arXiv

EV Dispatch Control for Supplementary Frequency Regulation Considering the Expectation of EV Owners

Electric Vehicles (EVs) are promising to provide frequency regulation services due to their fast regulating characteristics. However, when EVs participate in Supplementary Frequency Regulation (SFR), it is challenging to simultaneously achieve the dispatch of the control center and the expected State of Charge (SOC) levels of EV batteries. To solve this problem, in this paper we propose a Vehicle-to-Grid (V2G) control strategy, in which an uncertain dispatch is implemented in the control center without detailed EV charging/discharging information. The regulation from the control center is achieved by allocating the regulation task within the frequency regulation capacity (FRC) of EVs. The expected SOC levels of EV batteries are guaranteed by a real-time correction of their scheduled V2G power in EV charging stations. Simulations on an interconnected two-area power system validate the effectiveness of the proposed V2G control in achieving both the frequency regulation and the expected SOC levels of EVs.

preprint2016arXiv

Interval Estimation for Conditional Failure Rates of Transmission Lines with Limited Samples

The estimation of the conditional failure rate (CFR) of an overhead transmission line (OTL) is essential for power system operational reliability assessment. It is hard to predict the CFR precisely, although great efforts have been made to improve the estimation accuracy. One significant difficulty is the lack of available outage samples, due to which the law of large numbers is no longer applicable and no convincing statistical result can be obtained. To address this problem, in this paper a novel imprecise probabilistic approach is proposed to estimate the CFR of an OTL. The imprecise Dirichlet model (IDM) is applied to establish the imprecise probabilistic relation between a single conditional variable and the failure rate of an OTL. Then a credal network is constructed to integrate the IDM estimation results corresponding to different conditional variables and infer the CFR. Instead of providing a single-valued estimation result, the proposed approach predicts the possible interval of the CFR in order to explicitly indicate the uncertainty of the estimation and more objectively represent the available knowledge. The proposed approach is illustrated by estimating the CFRs of two LGJ-300 transmission lines located in the same region; the test results validate its effectiveness.

preprint2016arXiv

Nonlinear Model Reduction in Power Systems by Balancing of Empirical Controllability and Observability Covariances

In this paper, nonlinear model reduction for power systems is performed by the balancing of empirical controllability and observability covariances that are calculated around the operating region. Unlike existing model reduction methods, the external system does not need to be linearized but is directly dealt with as a nonlinear system. A transformation is found to balance the controllability and observability covariances in order to determine which states have the greatest contribution to the input-output behavior. The original system model is then reduced by Galerkin projection based on this transformation. The proposed method is tested and validated on a system comprised of a 16-machine 68-bus system and an IEEE 50-machine 145-bus system. The results show that by using the proposed model reduction the calculation efficiency can be greatly improved; at the same time, the obtained state trajectories are close to those for directly simulating the whole system or partitioning the system while not performing reduction. Compared with the balanced truncation method based on a linearized model, the proposed nonlinear model reduction method can guarantee higher accuracy and similar calculation efficiency. It is shown that the proposed method is not sensitive to the choice of the matrices for calculating the empirical covariances.

preprint2016arXiv

Optimal Placement of Dynamic Var Sources by Using Empirical Controllability Covariance

In this paper, the empirical controllability covariance (ECC), which is calculated around the considered operating condition of a power system, is applied to quantify the degree of controllability of system voltages under specific dynamic var source locations. An optimal dynamic var source placement method addressing fault-induced delayed voltage recovery (FIDVR) issues is further formulated as an optimization problem that maximizes the determinant of ECC. The optimization problem is effectively solved by the NOMAD solver, which implements the Mesh Adaptive Direct Search algorithm. The proposed method is tested on an NPCC 140-bus system and the results show that the proposed method with fault specified ECC can solve the FIDVR issue caused by the most severe contingency with fewer dynamic var sources than the Voltage Sensitivity Index (VSI) based method. The proposed method with fault unspecified ECC does not depend on the settings of the contingency and can address more FIDVR issues than VSI method when placing the same number of SVCs under different fault durations. It is also shown that the proposed method can help mitigate voltage collapse.

preprint2016arXiv

Risk Mitigation for Dynamic State Estimation Against Cyber Attacks and Unknown Inputs

Phasor measurement units (PMUs) can be effectively utilized for the monitoring and control of the power grid. As the cyber-world becomes increasingly embedded into power grids, the risks of this inevitable evolution become serious. In this paper, we present a risk mitigation strategy, based on dynamic state estimation, to eliminate threat levels from the grid's unknown inputs and potential cyber-attacks. The strategy requires (a) the potentially incomplete knowledge of power system models and parameters and (b) real-time PMU measurements. First, we utilize a dynamic state estimator for higher order depictions of power system dynamics for simultaneous state and unknown inputs estimation. Second, estimates of cyber-attacks are obtained through an attack detection algorithm. Third, the estimation and detection components are seamlessly utilized in an optimization framework to determine the most impacted PMU measurements. Finally, a risk mitigation strategy is proposed to guarantee the elimination of threats from attacks, ensuring the observability of the power system through available, safe measurements. Case studies are included to validate the proposed approach. Insightful suggestions, extensions, and open problems are also posed.

preprint2015arXiv

Decentralized Voltage and Power Regulation Control of Excitation and Governor System with Global Asymptotic Stability

The Global Asymptotic Stability (GAS), Voltage Regulation (VR), and Power Regulation (PR) of the excitation and governor control system are of critical importance for power system security. However, simultaneously fulfilling GAS, VR, and PR has not yet been achieved. In order to solve this problem, in this paper, we propose a Lyapunov-based decentralized Control (LBC) for the excitation and governor system of multi-machine power system. A completely controllable linear system is actively constructed to design the time-derivative of the Lyapunov function and GAS is guaranteed by satisfying the condition of GAS in Lyapunov theorem. At the same time, VR and PR are performed by introducing both voltage and power to the feedback. The effectiveness of the proposed method is tested and validated on a six-machine power system.

preprint2015arXiv

Dynamic State Estimation under Cyber Attacks: A Comparative Study of Kalman Filters and Observers

Utilizing highly synchronized measurements from synchrophasors, dynamic state estimation (DSE) can be applied for real-time monitoring of smart grids. Concurrent DSE studies for power systems are intolerant to unknown inputs and potential attack vectors --- a research gap we will fill in this work. Particularly, we (a) present an overview of concurrent estimation techniques, highlighting key deficiencies, (b) develop DSE methods based on cubature Kalman filter and dynamic observers, (c) rigorously examine the strengths and weaknesses of the proposed methods under attack-vectors and unknown inputs, and (d) provide comprehensive recommendations for DSE. Numerical results and in-depth remarks are also presented.

preprint2014arXiv

Optimal PMU Placement for Power System Dynamic State Estimation by Using Empirical Observability Gramian

In this paper the empirical observability Gramian calculated around the operating region of a power system is used to quantify the degree of observability of the system states under specific phasor measurement unit (PMU) placement. An optimal PMU placement method for power system dynamic state estimation is further formulated as an optimization problem which maximizes the determinant of the empirical observability Gramian and is efficiently solved by the NOMAD solver, which implements the Mesh Adaptive Direct Search (MADS) algorithm. The implementation, validation, and also the robustness to load fluctuations and contingencies of the proposed method are carefully discussed. The proposed method is tested on WSCC 3-machine 9-bus system and NPCC 48-machine 140-bus system by performing dynamic state estimation with square-root unscented Kalman filter. The simulation results show that the determined optimal PMU placements by the proposed method can guarantee good observability of the system states, which further leads to smaller estimation errors and larger number of convergent states for dynamic state estimation compared with random PMU placements. Under optimal PMU placements an obvious observability transition can be observed. The proposed method is also validated to be very robust to both load fluctuations and contingencies.

preprint2014arXiv

Power System Dynamic State Estimation by Unscented Kalman Filter with Guaranteed Positive Semidefinite State Covariance

In this paper an unscented Kalman filter with guaranteed positive semidefinite state covariance is proposed by calculating the nearest symmetric positive definite matrix in Frobenius norm and is applied to power system dynamic state estimation. The proposed method is tested on NPCC 48-machine 140-bus system and the results validate its effectiveness.

preprint2013arXiv

A Cascading Failure Model by Quantifying Interactions

Cascading failures triggered by trivial initial events are encountered in many complex systems. It is the interaction and coupling between components of the system that causes cascading failures. We propose a simple model to simulate cascading failure by using the matrix that determines how components interact with each other. A careful comparison is made between the original cascades and the simulated cascades by the proposed model. It is seen that the model can capture general features of the original cascades, suggesting that the interaction matrix can well reflect the relationship between components. An index is also defined to identify important links and the distribution follows an obvious power law. By eliminating a small number of most important links the risk of cascading failures can be significantly mitigated, which is dramatically different from getting rid of the same number of links randomly.