Source author record

Junghyun Bae

Junghyun Bae appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
5topics
1close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

A New Semi-Empirical Model for Cosmic Ray Muon Flux Estimation

Cosmic ray muons have emerged as a non-conventional high-energy radiation probe to monitor dense and large objects. Muons are the most abundant cosmic radiation on Earth, however, their flux at sea level is approximately 10,000 min^-1m^-2 much less than that of induced radiation. In addition, cosmic ray muon flux depends on not only various natural conditions (e.g., zenith angle, altitude, or solar activities) but also the geometric characteristic of detectors. Since the low muon flux typically results in long measurement times, an accurate estimation of measurable muon counts is important for muon applications. Here we propose a simple and versatile semi-empirical model to improve the accuracy in muon flux estimation at all zenith angles by incorporating the geometric parameters of detectors, and we name this the Effective Solid Angle model. To demonstrate the functionality, our model is compared with i) the cosine-squared, ii) PARMA model, and iii) Monte-Carlo simulations, and iv) measurements. Our results show that the muon count rate estimation capability is significantly improved resulting in increasing a mean C/E from 0.7 to 0.95. By selecting an appropriate intensity correlation, the model can be easily extended to estimate muon flux at various altitude and underground level.

preprint2022arXiv

Development of Compact Muon Spectrometer Using Multiple Pressurized Gas Cherenkov Radiators

In both particle physics and muon applications, a high-resolution muon momentum measurement capability plays a significant role not only in providing valuable information on the properties of subatomic particles but also in improving the utilizability of cosmic ray muons. Typically, muon momentum is measured by reconstructing a curved muon path using a strong magnetic field and muon trackers. Alternatively, a time-of-flight and Cherenkov ring imager are less frequently applied, especially when there is a need to avoid a magnetic field. However, measurement resolution is much less than that of magnetic spectrometers, approximately 20% whereas it is nearly 4% or less when using magnets and trackers. Here, we propose a different paradigm to estimate muon momentum that utilizes multiple pressurized gas Cherenkov radiators. Using the fact that the refractive index of gas medium varies depending on its pressure and temperature, we can optimize the muon Cherenkov threshold momentum levels for which a muon signal will be detected. In this work, we demonstrate that muon momentum can be estimated with mean resolution of {sigma_p}/p < 20% and mean classification rate of 90.08% in the momentum range of 0.1 to 10.0 GeV/c by analyzing optical photon signals from each Cherenkov radiator. We anticipate our new spectrometer will significantly improve quality of imaging and reduce scanning time in cosmic ray muon applications by being incorporated with existing instruments.

preprint2022arXiv

Fieldable Muon Momentum Measurement using Coupled Pressurized Gaseous Cherenkov Detectors

Cosmic ray muons present a large part of the radiation background and depending on the application of interest muons can be seen as background noise, e.g., radiation mapping, radiation protection, dosimetry, or as a useful interrogation probe such as cosmic ray muon tomography. It is worth noting recent developments on muon scattering tomography which has emerged as a prospective noninvasive monitoring method for many applications including spent nuclear fuel cask monitoring and geotomography. However, it is still very challenging to measure muon momentum in the field, despite the apparent benefits, without resorting to large and expensive calorimeters, ring imagers, or time of flight detectors. Recent efforts at CNL and INFN have developed large prototypes based on multiple Coulomb scattering coupled with the muon momentum reconstruction algorithms. While these efforts show promise, no portable detectors exist that can measure muon momentum in the field. In this work, we present a new concept for measuring muon momentum using coupled pressurized gaseous Cherenkov radiators. By carefully selecting the gas pressure at each radiator we can optimize the muon momentum threshold for which a muon signal will be detected. This way, a muon passing through the radiators will only trigger those radiators with momentum threshold less than the actual muon momentum. By measuring the presence of Cherenkov signals in each radiator, our system can then estimate the muon momentum. The primary benefit of such a concept is that it can be compact and portable enough so that it can be deployed in the field separately or in combination with existing tomography systems.

preprint2022arXiv

Fieldable muon spectrometer using multi-layer pressurized gas Cherenkov radiators and its applications

Cosmic ray muons have been considered as a non-conventional radiation probe in various applications. To utilize cosmic ray muons in engineering applications, two important quantities, trajectory and momentum, must be known. The muon trajectories are easily reconstructed using two-fold detector arrays with a high spatial resolution. However, precise measurement of muon momentum is difficult to be achieved without deploying large and expensive spectrometers such as solenoid magnets. Here, we propose a new method to estimate muon momentum using multi-layer pressurized gas Cherenkov radiators. This is accurate, portable, compact (< 1m3), and easily coupled with existing muon detectors without the need of neither bulky magnetic nor time-of-flight spectrometers. The results show that not only our new muon spectrometer can measure muon momentum with a resolution of +-0.5 GeV/c in a momentum range of 0.1 to 10.0 GeV/c, but also we can reconstruct cosmic muon spectrum with high accuracy (~90%).

preprint2022arXiv

Non-linear Cherenkov Muon Spectrometer Using Multi-Layer Pressurized C3F8 Gas Radiators

A new Cherenkov muon spectrometer using diversely sized C3F8 gas radiators and nonlinear threshold muon momentum levels was studied using Geant4 simulations. Despite its compact size (<1m3), the performance of the spectrometer was significantly improved over the earlier design (linear and uniform) in two aspects, (i) a stable momentum measurement resolution and (ii) a balanced expected Cherenkov photon yields in all radiators. In addition, CO2 gas radiators are replaced by heavier gas radiators, C3F8, and the sizes of radiators for high momentum levels (low gas pressure) are enlarged to increase the Cherenkov photon yields. Specifically, the absolute momentum resolution, σp, for all levels is replaced by the relative momentum resolution, σp/p. To demonstrate the functionality of our proposed Cherenkov muon spectrometer, we presented the results of classification rates as a function of muon momentum with various discriminator levels and reconstructed cosmic ray muon spectrum. When the combination of two or more discriminators are used, the average classification rate is 90.08%. In addition, our proposed Cherenkov muon spectrometer successfully reconstructed the cosmic ray muon spectrum and the results show a good agreement with the actual spectrum within 1σ in most momentum levels.

preprint2022arXiv

The Effect of Cosmic Ray Muon Momentum Measurement for Monitoring Shielded Special Nuclear Materials

Recently, cosmic ray muons have been considered as a potential high energy radiation probe for monitoring and interrogation of dense, well-shielded special nuclear materials (SNM). Due to their high-penetrative nature, cosmic ray muons can easily penetrate shielded nuclear materials with minimal absorption and with leaving the target objects intact. However, despite the potential benefits from using cosmic ray muons for SNM monitoring, their widespread application has been limited for various reasons, including relatively low cosmic ray muon flux at sea level and the difficulty of measuring muon momentum in the field which can increase resolution and reduce measurement time. In this work, we explore in detail the effect of cosmic ray muon momentum measurement, focusing specifically on SNM monitoring applications. Three different types of SNMs (HEU, LEU, and Pu) surrounded by lead shielding with five different thicknesses (0, 5, 10, 20, and 30 cm), are analyzed using Monte Carlo simulation for three momentum measurement resolution levels (perfect, limited, and absent). 1000 muons were generated in the simulation which translates to 4 minutes of measurement time for a standard cargo container. We found that it is possible to identify and separate HEU, LEU, and Pu with high accuracy (> 3 s.d.) when using muon momentum measurement (perfect and limited) even when 30 cm-thick lead shielding was used. Currently, it is not possible to identify or separate the SNMs with 30 cm thick lead shielding without muon momentum knowledge. Our results show that the effect of measuring muon momentum can be significant and can result in reduced measurement times by a factor of 3 to 4 and/or improved monitoring and imaging resolution.