Source author record

Julian Stirling

Julian Stirling appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

Multi-modal microscopy imaging with the OpenFlexure Delta Stage

Microscopes are vital pieces of equipment in much of biological research and medical diagnostics. However, access to a microscope can represent a bottleneck in research, especially in lower-income countries. `Smart' computer controlled motorized microscopes, which can perform automated routines or acquire images in a range of modalities are even more expensive and inaccessible. Developing low-cost, open-source, smart microscopes enables more researchers to conceive and execute optimized or more complex experiments. Here we present the OpenFlexure Delta Stage, a 3D-printed microscope designed for researchers. Powered by the OpenFlexure software stack, it is capable of performing automated experiments. The design files and assembly instructions are freely available under an open licence. Its intuitive and modular design -- along with detailed documentation -- allows researchers to implement a variety of imaging modes with ease. The versatility of this microscope is demonstrated by imaging biological and non-biological samples (red blood cells with Plasmodium parasites and colloidal particles in brightfield, epi-fluorescence, darkfield, Rheinberg and differential phase contrast. We present the design strategy and choice of tools to develop devices accessible to researchers from lower-income countries, as well as the advantages of an open-source project in this context. This microscope, having been open-source since its conception, has already been built and tested by researchers around the world, promoting a community of expertise and an environment of reproducibility in science.

preprint2021arXiv

Modern Microscopy with the Web of Things: The OpenFlexure Microscope Software Stack

Automated and computerised control of scientific instrumentation is almost ubiquitous in the modern laboratory. Most instrumentation is controlled over decades old communication busses or is accessed via proprietary system libraries. This limits which languages and operating systems can be used to control instruments, and poses a significant problem when interfacing multiple instruments into the same experiment. Here we present the OpenFlexure Microscope software stack as an example of how a scientific instrument can be controlled using existing, cross-platform, language-independent, industry-supported standards. We split the control code into client and server applications interfaced via a web API that conforms to the W3C Web of Things standard. This enables simple control of the microscope from multiple languages, provides a modern graphical control interface, and minimises duplicated code. Network control also makes the software stack more robust, allows multiple microscopes to be controlled by one computer, and facilitates sharing of equipment between local or remote users. Using a Web of Things approach in research laboratories has the potential to solve many of the key challenges of experiment integration, using technology that is already well established.

preprint2019arXiv

Closed form expressions for gravitational multipole moments of elementary solids

Perhaps the most powerful method for deriving the Newtonian gravitational interaction between two masses is the multipole expansion. Once inner multipoles are calculated for a particular shape this shape can be rotated, translated, and even converted to an outer multipole with well established methods. The most difficult stage of the multipole expansion is generating the initial inner multipole moments without resorting to three dimensional numerical integration of complex functions. Previous work has produced expressions for the low degree inner multipoles for certain elementary solids. This work goes further by presenting closed form expressions for all degrees and orders. A combination of these solids, combined with the aforementioned multipole transformations, can be used to model the complex structures often used in precision gravitation experiments.

preprint2019arXiv

Flat-field and colour correction for the Raspberry Pi camera module

The Raspberry Pi camera module is widely used in open source hardware projects as a low cost camera sensor. However, when the stock lens is removed and replaced with other custom optics the sensor will return a non-uniform background and colour response which hampers the use of this excellent and popular image sensor. This effect is found to be due to the sensor's optical design as well as due to built-in corrections in the GPU firmware, which is optimised for a short focal length lens. In this work we characterise and correct the vignetting and colour crosstalk found in the Raspberry Pi camera module v2, presenting two measures that greatly improve the quality of images using custom optics. First, we use a custom "lens shading table" to correct for vignetting of the image, which can be done in real time in the camera's existing processing pipeline (i.e. the camera's low-latency preview is corrected). The second correction is a colour unmixing matrix, which enables us to reverse the loss in saturation at the edge of the image, though this requires post-processing of the image. With both of these corrections in place, it is possible to obtain uniformly colour-corrected images, at the expense of slightly increased noise at the edges of the image.

preprint2019arXiv

The OpenFlexure Block Stage: Sub-100 nm fibre alignment with a monolithic plastic flexure stage

As 3D printers become more widely available, researchers are able to rapidly produce components that may have previously taken weeks to have machined. The resulting plastic components, having high surface roughness, are often not suitable for high-precision optomechanics. However, by playing to the strengths of 3D printing---namely the ability to print complex internal geometries---it is possible to design monolithic mechanisms that do not rely on tight integration of high-precision parts. Here we present a motorised monolithic 3D-printed plastic flexure stage with sub-100 nm resolution, that can perform automated optical fibre alignment.

preprint2014arXiv

A self-calibrating optomechanical force sensor with femtonewton resolution

We report the development of an ultrasensitive optomechanical sensor designed to improve the accuracy and precision of force measurements with atomic force microscopy. The sensors reach quality factors of 4.3x10^6 and force resolution on the femtonewton scale at room temperature. Self-calibration of the sensor is accomplished using radiation pressure to create a reference force. Self-calibration enables in situ calibration of the sensor in extreme environments, such as cryogenic ultra-high vacuum. The senor technology presents a viable route to force measurements at the atomic scale with uncertainties below the percent level.

preprint2013arXiv

Critical assessment of the evidence for striped nanoparticles

There is now a significant body of literature in which it is claimed that stripes form in the ligand shell of suitably functionalised Au nanoparticles. This stripe morphology has been proposed to strongly affect the physicochemical and biochemical properties of the particles. We critique the published evidence for striped nanoparticles in detail, with a particular focus on the interpretation of scanning tunnelling microscopy (STM) data (as this is the only technique which ostensibly provides direct evidence for the presence of stripes). Through a combination of an exhaustive re-analysis of the original data with new experimental measurements of a simple control sample comprising entirely unfunctionalised particles, we conclusively show that all of the STM evidence for striped nanoparticles published to date can instead be explained by a combination of well-known instrumental artefacts, strong observer bias, and/or improper data acquisition/analysis protocols. We also critically re-examine the evidence for the presence of ligand stripes which has been claimed to have been found from transmission electron microscopy, nuclear magnetic resonance spectroscopy, small angle neutron scattering experiments, and computer simulations. Although these data can indeed be interpreted in terms of stripe formation, we show that, just as for the STM measurements, rather more mundane interpretations can account for the reported results.