Source author record

Joseph A. O'Sullivan

Joseph A. O'Sullivan appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

8works
10topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2022arXiv

A Metal Artifact Reduction Scheme For Accurate Iterative Dual-Energy CT Algorithms

CT images have been used to generate radiation therapy treatment plans for more than two decades. Dual-energy CT (DECT) has shown high accuracy in estimating electronic density or proton stopping-power maps used in treatment planning. However, the presence of metal implants introduces severe streaking artifacts in the reconstructed images, affecting the diagnostic accuracy and treatment performance. In order to reduce the metal artifacts in DECT, we introduce a metal-artifact reduction scheme for iterative DECT algorithms. An estimate is substituted for the corrupt data in each iteration. We utilize normalized metal-artifact reduction (NMAR) composed with image-domain decomposition to initialize the algorithm and speed up the convergence. A fully 3D joint statistical DECT algorithm, dual-energy alternating minimization (DEAM), with the proposed scheme is tested on experimental and clinical helical data acquired on a Philips Brilliance Big Bore scanner. We compared DEAM with the proposed method to the original DEAM and vendor reconstructions with and without metal-artifact reduction for orthopedic implants (O-MAR). The visualization and quantitative analysis show that DEAM with the proposed method has the best performance in reducing streaking artifacts caused by metallic objects.

preprint2016arXiv

Joint System and Algorithm Design for Computationally Efficient Fan Beam Coded Aperture X-ray Coherent Scatter Imaging

In x-ray coherent scatter tomography, tomographic measurements of the forward scatter distribution are used to infer scatter densities within a volume. A radiopaque 2D pattern placed between the object and the detector array enables the disambiguation between different scatter events. The use of a fan beam source illumination to speed up data acquisition relative to a pencil beam presents computational challenges. To facilitate the use of iterative algorithms based on a penalized Poisson log-likelihood function, efficient computational implementation of the forward and backward models are needed. Our proposed implementation exploits physical symmetries and structural properties of the system and suggests a joint system-algorithm design, where the system design choices are influenced by computational considerations, and in turn lead to reduced reconstruction time. Computational-time speedups of approximately 146 and 32 are achieved in the computation of the forward and backward models, respectively. Results validating the forward model and reconstruction algorithm are presented on simulated analytic and Monte Carlo data.

preprint2016arXiv

Spectrally Grouped Total Variation Reconstruction for Scatter Imaging Using ADMM

We consider X-ray coherent scatter imaging, where the goal is to reconstruct momentum transfer profiles (spectral distributions) at each spatial location from multiplexed measurements of scatter. Each material is characterized by a unique momentum transfer profile (MTP) which can be used to discriminate between different materials. We propose an iterative image reconstruction algorithm based on a Poisson noise model that can account for photon-limited measurements as well as various second order statistics of the data. To improve image quality, previous approaches use edge-preserving regularizers to promote piecewise constancy of the image in the spatial domain while treating each spectral bin separately. Instead, we propose spectrally grouped regularization that promotes piecewise constant images along the spatial directions but also ensures that the MTPs of neighboring spatial bins are similar, if they contain the same material. We demonstrate that this group regularization results in improvement of both spectral and spatial image quality. We pursue an optimization transfer approach where convex decompositions are used to lift the problem such that all hyper-voxels can be updated in parallel and in closed-form. The group penalty introduces a challenge since it is not directly amendable to these decompositions. We use the alternating directions method of multipliers (ADMM) to replace the original problem with an equivalent sequence of sub-problems that are amendable to convex decompositions, leading to a highly parallel algorithm. We demonstrate the performance on real data.

preprint2016arXiv

Stochastic First-Order Minimization Techniques Using Jensen Surrogates for X-Ray Transmission Tomography

Image reconstruction in X-ray transmission tomography has been an important research field for decades. In light of data volume increasing faster than processor speeds, one needs accelerated iterative algorithms to solve the optimization problem in the X-ray CT application. Incremental methods, in which a subset of data is being used at each iteration to accelerate the computations, have been getting more popular lately in the machine learning and mathematical optimization fields. The most popular member of this family of algorithms in the X-ray CT field is ordered-subsets. Even though it performs well in earlier iterations, the lack of convergence in later iterations is a known phenomenon. In this paper, we propose two incremental methods that use Jensen surrogates for the X-ray CT application, one stochastic and one ordered-subsets type. Using measured data, we show that the stochastic variant we propose outperforms other algorithms, including the gradient descent counterparts.

preprint2015arXiv

Alternating Minimization Algorithm with Automatic Relevance Determination for Transmission Tomography under Poisson Noise

We propose a globally convergent alternating minimization (AM) algorithm for image reconstruction in transmission tomography, which extends automatic relevance determination (ARD) to Poisson noise models with Beer's law. The algorithm promotes solutions that are sparse in the pixel/voxel-differences domain by introducing additional latent variables, one for each pixel/voxel, and then learning these variables from the data using a hierarchical Bayesian model. Importantly, the proposed AM algorithm is free of any tuning parameters with image quality comparable to standard penalized likelihood methods. Our algorithm exploits optimization transfer principles which reduce the problem into parallel 1D optimization tasks (one for each pixel/voxel), making the algorithm feasible for large-scale problems. This approach considerably reduces the computational bottleneck of ARD associated with the posterior variances. Positivity constraints inherent in transmission tomography problems are also enforced. We demonstrate the performance of the proposed algorithm for x-ray computed tomography using synthetic and real-world datasets. The algorithm is shown to have much better performance than prior ARD algorithms based on approximate Gaussian noise models, even for high photon flux.

preprint2015arXiv

Combined 3D PET and Optical Projection Tomography Techniques for Plant Root Phenotyping

New imaging techniques are in great demand for investigating underground plant roots systems which play an important role in crop production. Compared with other non-destructive imaging modalities, PET can image plant roots in natural soil and produce dynamic 3D functional images which reveal the temporal dynamics of plant-environment interactions. In this study, we combined PET with optical projection tomography (OPT) to evaluate its potential for plant root phenotyping. We used a dedicated high resolution plant PET imager that has a 14 cm transaxial and 10 cm axial field of views, and multi-bed imaging capability. The image resolution is around 1.25 mm using ML-EM reconstruction algorithm. B73 inbred maize seeds were germinated and then grown in a sealed jar with transparent gel-based media. PET scanning started on the day when the first green leaf appeared, and was carried out once a day for 5 days. Each morning, around 10 mCi of 11CO2 was administrated into a custom built plant labeling chamber. After 10 minutes, residual activity was flushed out with fresh air before a 2-h PET scan started. For the OPT imaging, the jar was placed inside an acrylic cubic container filled with water, illuminated with a uniform surface light source, and imaged by a DSLR camera from 72 angles to acquire optical images for OPT reconstruction. The same plant was imaged 3 times a day by the OPT system. Plant roots growth is measured from the optical images. Co-registered PET and optical images indicate that most of the hot spots appeared in later time points of the PET images correspond to the most actively growing root tips. The strong linear correlation between 11C allocation at root tips measured by PET and eventual root growth measured by OPT suggests that we can use PET as a phenotyping tool to measure how a plant makes subterranean carbon allocation decisions in different environmental scenarios.

preprint2015arXiv

Multiresolution Approach to Acceleration of Iterative Image Reconstruction for X-Ray Imaging for Security Applications

Three-dimensional x-ray CT image reconstruction in baggage scanning in security applications is an important research field. The variety of materials to be reconstructed is broader than medical x-ray imaging. Presence of high attenuating materials such as metal may cause artifacts if analytical reconstruction methods are used. Statistical modeling and the resultant iterative algorithms are known to reduce these artifacts and present good quantitative accuracy in estimates of linear attenuation coefficients. However, iterative algorithms may require computations in order to achieve quantitatively accurate results. For the case of baggage scanning, in order to provide fast accurate inspection throughput, they must be accelerated drastically. There are many approaches proposed in the literature to increase speed of convergence. This paper presents a new method that estimates the wavelet coefficients of the images in the discrete wavelet transform domain instead of the image space itself. Initially, surrogate functions are created around approximation coefficients only. As the iterations proceed, the wavelet tree on which the updates are made is expanded based on a criterion and detail coefficients at each level are updated and the tree is expanded this way. For example, in the smooth regions of the image the detail coefficients are not updated while the coefficients that represent the high-frequency component around edges are being updated, thus saving time by focusing computations where they are needed. This approach is implemented on real data from a SureScan (TM) x1000 Explosive Detection System and compared to straightforward implementation of the unregularized alternating minimization of O'Sullivan and Benac [1].

preprint2014arXiv

A dedicated high resolution PET imager for plant sciences

PET provides in vivo molecular and functional imaging capability that is crucial to studying the interaction of plant with changing environment at the whole-plant level. We have developed a dedicated plant PET imager that features high spatial resolution, housed in a fully controlled environment provided by a plant growth chamber (PGC). The system currently contains two types of detector modules: 84 microPET R4 block detectors with 2.2 mm crystals to provide a large detecting area; and 32 Inveon block detectors with 1.5 mm crystals to provide higher spatial resolution. Outputs of the four microPET block detectors in a modular housing are concatenated by a custom printed circuit board to match the output characteristics of an Inveon detector. All the detectors are read out by QuickSilver electronics. The detector modules are configured to full rings with a 15 cm diameter trans-axial field of view (FOV) for dynamic tomographic imaging of small plants. Potentially, the Inveon detectors can be reconfigured to quarter-rings to get a 25 cm FOV using step-and-shoot motion. The imager contains 2 linear stages to position detectors at different heights for multi-bed scanning, and 2 rotation stages to collect coincidence events from all angles. The PET system has been built and integrated into the PGC. The system has a typical energy resolution of 15% for Inveon blocks and 24% for R4 blocks; timing resolution of 1.8 ns; and sensitivity of 1.3%,1.4%,3.0% measured at center of FOV, 5 cm off to R4 half-ring and 5 cm off to Inveon half-ring, respectively(with a 350-650 KeV energy and 3.1 ns timing window). System spatial resolution is similar to that of commercial microPET sytems, with 1.25 mm rod sources in the micro-Derenzo phantom resolved using ML-EM algorithm. Preliminary imaging experiments using different plants labeled with 11C-CO2 produced high-quality dynamic PET images.