Source author record

José Lipovetzky

José Lipovetzky appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2021arXiv

X-ray characterization of BUSARD chip: A HV-SOI monolithic particle detector with pixel sensors under the buried oxide

This work presents the design of BUSARD, an application specific integrated circuit (ASIC) for the detection of ionizing particles. The ASIC is a monolithic active pixel sensor which has been fabricated in a High-Voltage Silicon-On-Insulator (HV-SOI) process that allows the fabrication of a buried N+ diffusion below the Buried OXide (BOX) as a standard processing step. The first version of the chip, BUSARD-A, takes advantage of this buried diffusion as an ionizing particle sensor. It includes a small array of 13$\times$13 pixels, with a pitch of $80\,μ$m, and each pixel has one buried diffusion with a charge amplifier, discriminator with offset tuning and digital processing. The detector has several operation modes including particle counting and Time-over-Threshold (ToT). An initial X-ray characterization of the detector was carried out, obtaining several pulse height and ToT spectra, which then were used to perform the energy calibration of the device. The Molybdenum $\mathbf{K_α}$ emission was measured with a standard deviation of $127\,e^{-}$ of ENC by using the analog pulse output, and with $276\,e^{-}$ of ENC by using the ToT digital output. The resolution in ToT mode is dominated by the pixel-to-pixel variation.

preprint2020arXiv

COTS MOS Dosimetry on the MeMOSat Board, Results After 2.5 Years in Orbit

We present the results after 2.5 years in or-bit of Total Ionizing Dose (TID) measurements done using Metal Oxide Semiconductor (MOS) dosimeters on the MeMOSat board. The MeMOSat board was launched on July 19th 2014 at the BugSat-1 "Tita" microsatellite developed by Satellogic to stay at LEO. We used as dosimeters p-channel Commercial Off The Shelf (COTS) MOS transistors with gate oxides of 250~nm. Before launch, a subset of transistors with similar drain current to voltage (I-V)curves where selected from a group of 100 devices. The temperature dependence of the (I-V) curves was studied to find the minimum temperature coefficient biasing point. Then, a calibration subgroup of sensors was irradiated using a $^{60}$Co gamma source to study their response to TID, showing responsivities of $\sim$75~mV/krad when the sensors are irradiated without gate bias. Also, the post irradiation response of the sensors was monitored, in order to include a correction for low dose rate irradiations, yielding 30~mV/krad. A biasing and reading circuit was developed in order to allow the reading of up to 4 sensors.The threshold voltage was monitored during different periods of the mission. After 2.5 years in orbit,the threshold voltage of the sensor mounted on the MeMOSat Board had a V$_\mathrm{T}$ shift of approximately 35~mV corresponds to a dose of 1.2~krads.